PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 110V · 550W · SSR SSR10DA
QC pad (MAC) : 02813B23751D
Start : 2026-08-07T03:02:44.675633 · End : 2026-08-07T03:18:05.415946 · Duration : 920 s
Received (server) : 2026-08-07T03:20:54
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=550 ssr=SSR10DA lot=20260618 uid=2ACAAE

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 03:02:44
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=0B0044000D51353234323830
Home X PASS 03:03:10
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.8019 gap=2.1981 (2/4) tap 4: pos=457.1919 gap=1.8081 (3/4) tap 5: pos=456.8019 gap=2.1981 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9481 spread=0.3900mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 03:03:44
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 03:04:11
Part fan PASS 03:04:13
Hotend fan PASS 03:04:15
Hotend heat 220°C PASS 03:04:15
Bed heat 60°C PASS 03:07:05
Cutter (feed+cut) PASS 03:08:39
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=457.1919 gap=1.8081 (2/4) tap 4: pos=456.8019 gap=2.1981 (3/4) tap 5: pos=457.1919 gap=1.8081 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.0456 spread=0.3900mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 03:08:53
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 03:11:57
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=457.1919 gap=1.8081 (1/4) tap 3: pos=456.8019 gap=2.1981 (2/4) tap 4: pos=457.1919 gap=1.8081 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.0456 spread=0.3900mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=495.757500 probe at 49.995,339.999 is z=405.180000 Tap drift (diff=90.5775mm) — reset probe at 49.995,339.999 is z=405.187500 Tap OK (diff=0.0075mm, stable 2/5) probe at 49.995,339.999 is z=405.197500 Tap drift (diff=0.0100mm) — reset probe at 49.995,339.999 is z=405.817500 Tap drift (diff=0.6200mm) — reset probe at 49.995,339.999 is z=405.190000 Tap drift (diff=0.6275mm) — reset probe at 49.995,339.999 is z=405.192500 Tap OK (diff=0.0050mm, stable 3/5) probe at 49.995,339.999 is z=405.195000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=405.1950 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 03:17:19 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1200, 486.1025, 486.1050, 486.1075, 486.1000, 486.0975, 486.0975, 486.1050, 486.1050, 486.0975, 486.1025, 486.1025, 486.1025, 486.1000, 486.0975
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=122.107500 probe at 49.998,339.999 is z=61.190000 Tap drift (diff=60.9175mm) — reset probe at 49.998,339.999 is z=49.105000 Tap drift (diff=12.0850mm) — reset Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) probe at 49.998,339.999 is z=1.092500 Tap drift (diff=48.0125mm) — reset probe at 49.998,339.999 is z=1.112500 Tap drift (diff=0.0200mm) — reset probe at 49.998,339.999 is z=1.115000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 49.998,339.999 is z=1.120000 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=1.1200 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=486.095000 probe at 49.998,339.999 is z=486.102500 Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.100000 Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0025mm, stable 4/5) probe at 49.998,339.999 is z=486.105000 VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.092500 probe at 49.998,339.999 is z=486.097500 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0050mm, stable 4/5) probe at 49.998,339.999 is z=486.107500 VALIDATED: trigger_z=486.1075 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.087500 VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Screws tilt PASS 03:18:05
probe: at 54.997,328.001 bed will contact at z=1.132500 probe: at 54.997,328.001 bed will contact at z=1.140000 probe: at 54.997,328.001 bed will contact at z=1.052500 Probe samples exceed tolerance. Retrying... probe: at 54.997,328.001 bed will contact at z=1.125000 probe: at 54.997,328.001 bed will contact at z=1.112500 probe: at 380.001,328.001 bed will contact at z=1.015000 probe: at 380.001,328.001 bed will contact at z=1.022500 probe: at 380.001,328.001 bed will contact at z=1.002500 probe: at 380.001,101.996 bed will contact at z=0.932500 probe: at 380.001,101.996 bed will contact at z=0.922500 probe: at 380.001,101.996 bed will contact at z=0.952500 probe: at 54.997,101.996 bed will contact at z=1.050000 probe: at 54.997,101.996 bed will contact at z=1.022500 probe: at 54.997,101.996 bed will contact at z=1.062500 probe: at 217.505,214.498 bed will contact at z=1.030000 probe: at 217.505,214.498 bed will contact at z=1.082500 probe: at 217.505,214.498 bed will contact at z=1.037500 probe: at 217.505,214.498 bed will contact at z=1.067500 probe: at 217.505,214.498 bed will contact at z=1.060000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.12500 front right screw : x=397.0, y=298.0, z=1.01500 : adjust CCW 00:13 rear right screw : x=397.0, y=72.0, z=0.93250 : adjust CCW 00:23 rear left screw : x=72.0, y=72.0, z=1.05000 : adjust CCW 00:09 middle : x=234.5, y=184.5, z=1.06000 : adjust CCW 00:08