SmartPi 1
SmartPi 2

0F005C000C51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 110V · 550W · SSR SSR10DA
QC pad (MAC) : 02817A147AB3
Start : 2026-08-08T01:09:53.001157 · End : 2026-08-08T01:29:24.897007 · Duration : 1171 s
Received (server) : 2026-08-08T01:43:31
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=550 ssr=SSR10DA lot=20260618 uid=2ACAAE

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 01:09:53
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=0F005C000C51353234323830
Home X PASS 01:10:20
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 01:10:57
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 01:11:02
Part fan PASS 01:11:05
Hotend fan PASS 01:11:07
Hotend heat 220°C PASS 01:11:17
Bed heat 60°C PASS 01:12:51
Cutter (feed+cut) PASS 01:21:43
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 01:21:58
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 01:24:01
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=414.725000 probe at 49.995,339.999 is z=414.692500 Tap drift (diff=0.0325mm) — reset probe at 49.995,339.999 is z=414.682500 Tap OK (diff=0.0100mm, stable 2/5) probe at 49.995,339.999 is z=414.680000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=414.6800 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 01:28:43 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1525, 486.0925, 486.0950, 486.0925, 486.0825, 486.0950, 486.1000, 486.1025, 486.0975, 486.1000, 486.1000, 486.1000, 486.1000, 486.1000, 486.1000
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=495.792500 probe at 49.998,339.999 is z=1.152500 Tap drift (diff=494.6400mm) — reset probe at 49.998,339.999 is z=1.155000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=1.1525 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=486.090000 Tap OK (diff=0.0000mm, stable 2/5) probe at 49.998,339.999 is z=486.092500 VALIDATED: trigger_z=486.0925 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0000mm, stable 4/5) probe at 49.998,339.999 is z=486.095000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=486.0950 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0025mm, stable 3/5) probe at 49.998,339.999 is z=486.075000 Tap drift (diff=0.0200mm) — reset Tap OK (diff=0.0050mm, stable 2/5) probe at 49.998,339.999 is z=489.665000 probe at 49.998,339.999 is z=492.075000 Tap drift (diff=2.4100mm) — reset probe at 49.998,339.999 is z=486.080000 Tap drift (diff=5.9950mm) — reset probe at 49.998,339.999 is z=486.082500 VALIDATED: trigger_z=486.0825 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=489.460000 probe at 49.998,339.999 is z=492.122500 Tap drift (diff=2.6625mm) — reset Tap drift (diff=6.0275mm) — reset probe at 49.998,339.999 is z=486.097500 probe at 49.998,339.999 is z=486.100000 probe at 49.998,339.999 is z=486.102500 VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Screws tilt PASS 01:29:24
probe: at 54.997,328.001 bed will contact at z=1.612500 probe: at 54.997,328.001 bed will contact at z=1.550000 Probe samples exceed tolerance. Retrying... probe: at 54.997,328.001 bed will contact at z=1.595000 probe: at 54.997,328.001 bed will contact at z=1.565000 probe: at 380.001,328.001 bed will contact at z=1.697500 probe: at 380.001,328.001 bed will contact at z=1.735000 probe: at 380.001,328.001 bed will contact at z=1.690000 probe: at 380.001,101.996 bed will contact at z=1.547500 probe: at 380.001,101.996 bed will contact at z=1.535000 probe: at 380.001,101.996 bed will contact at z=1.540000 probe: at 54.997,101.996 bed will contact at z=1.450000 probe: at 54.997,101.996 bed will contact at z=1.452500 probe: at 54.997,101.996 bed will contact at z=1.462500 probe: at 217.505,214.498 bed will contact at z=1.630000 probe: at 217.505,214.498 bed will contact at z=1.635000 probe: at 217.505,214.498 bed will contact at z=1.632500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.56500 front right screw : x=397.0, y=298.0, z=1.69750 : adjust CW 00:16 rear right screw : x=397.0, y=72.0, z=1.54000 : adjust CCW 00:03 rear left screw : x=72.0, y=72.0, z=1.45250 : adjust CCW 00:13 middle : x=234.5, y=184.5, z=1.63250 : adjust CW 00:08