SmartPi 1
SmartPi 2

100042000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 0281AE52CB5F
Start : 2026-08-20T01:53:28.322379 · End : 2026-08-20T02:05:26.197744 · Duration : 717 s
Received (server) : 2026-08-20T02:14:36
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 01:53:28
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=100042000D51353234323830
Home X PASS 01:53:54
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=457.1797 gap=1.8203 (2/4) tap 4: pos=457.0091 gap=1.9909 (3/4) tap 5: pos=456.9847 gap=2.0153 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.0426 spread=0.1950mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 01:54:29
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-18.1919 gap=1.8081 (3/4) tap 5: pos=-18.5819 gap=1.4181 fenetre=0.5850/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.1919 spread=0.5850mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 01:54:33
Part fan PASS 01:54:35
Hotend fan PASS 01:54:37
Hotend heat 220°C PASS 01:54:50
Bed heat 60°C PASS 01:54:57
Cutter (feed+cut) PASS 01:56:32
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=457.1919 gap=1.8081 (1/4) tap 3: pos=456.9847 gap=2.0153 (2/4) tap 4: pos=457.0091 gap=1.9909 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.2072/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.0456 spread=0.2072mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 01:56:47
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 02:00:07
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.8019 gap=2.1981 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9481 spread=0.1950mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-18.7647 gap=1.2353 (1/4) tap 3: pos=-18.7891 gap=1.2109 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0244mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=427.927500 probe at 49.995,339.999 is z=430.842500 Tap drift (diff=2.9150mm) — reset probe at 49.995,339.999 is z=407.540000 Tap drift (diff=23.3025mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 49.995,339.999 is z=407.530000 Tap OK (diff=0.0100mm, stable 3/5) Tap drift (diff=0.0100mm) — reset probe at 49.995,339.999 is z=407.557500 Tap drift (diff=0.0175mm) — reset probe at 49.995,339.999 is z=407.545000 Tap drift (diff=0.0125mm) — reset probe at 49.995,339.999 is z=407.542500 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.995,339.999 is z=407.550000 Tap OK (diff=0.0075mm, stable 3/5) Tap OK (diff=0.0075mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=407.5425 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z tap repeatability PASS 02:04:43 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1375, 486.0875, 486.1000, 486.1000, 486.1000, 486.1000, 486.1000, 486.0975, 486.1025, 486.0950, 486.1025, 486.1000, 486.1000, 486.1000, 486.1000
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=492.540000 probe at 49.998,339.999 is z=485.692500 Tap drift (diff=6.8475mm) — reset probe at 49.998,339.999 is z=280.660000 Tap drift (diff=205.0325mm) — reset probe at 49.998,339.999 is z=282.892500 Tap drift (diff=2.2325mm) — reset probe at 49.998,339.999 is z=196.690000 Tap drift (diff=86.2025mm) — reset probe at 49.998,339.999 is z=1.122500 Tap drift (diff=195.5675mm) — reset probe at 49.998,339.999 is z=1.127500 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,339.999 is z=1.132500 Tap OK (diff=0.0050mm, stable 4/5) probe at 49.998,339.999 is z=1.137500 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=1.1375 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=486.085000 probe at 49.998,339.999 is z=486.087500 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.998,339.999 is z=486.090000 Tap OK (diff=0.0025mm, stable 3/5) probe at 49.998,339.999 is z=486.095000 Tap OK (diff=0.0075mm, stable 5/5) VALIDATED: trigger_z=486.0875 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.097500 Tap OK (diff=0.0000mm, stable 2/5) probe at 49.998,339.999 is z=486.100000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=486.0975 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Screws tilt PASS 02:05:26
probe: at 54.997,328.001 bed will contact at z=1.432500 probe: at 54.997,328.001 bed will contact at z=1.477500 probe: at 54.997,328.001 bed will contact at z=1.390000 Probe samples exceed tolerance. Retrying... probe: at 54.997,328.001 bed will contact at z=1.397500 probe: at 54.997,328.001 bed will contact at z=1.425000 probe: at 54.997,328.001 bed will contact at z=1.417500 probe: at 380.001,328.001 bed will contact at z=1.330000 probe: at 380.001,101.996 bed will contact at z=1.297500 probe: at 380.001,101.996 bed will contact at z=1.310000 probe: at 54.997,101.996 bed will contact at z=1.530000 probe: at 54.997,101.996 bed will contact at z=1.525000 probe: at 54.997,101.996 bed will contact at z=1.507500 probe: at 217.505,214.498 bed will contact at z=1.435000 probe: at 217.505,214.498 bed will contact at z=1.432500 probe: at 217.505,214.498 bed will contact at z=1.420000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.41750 front right screw : x=397.0, y=298.0, z=1.33000 : adjust CCW 00:10 rear right screw : x=397.0, y=72.0, z=1.29750 : adjust CCW 00:14 rear left screw : x=72.0, y=72.0, z=1.52500 : adjust CW 00:13 middle : x=234.5, y=184.5, z=1.43250 : adjust CW 00:02