SmartPi 1
SmartPi 2

110046000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 110V · 550W · SSR SSR10DA
QC pad (MAC) : 028103694A6F
Start : 2026-08-07T10:21:16.055733 · End : 2026-08-07T10:33:57.936030 · Duration : 761 s
Received (server) : 2026-08-07T02:37:59
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=550 ssr=SSR10DA lot=20260618 uid=2ACAAE

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 10:21:16
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=110046000D51353234323830
Home X PASS 10:21:41
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.0213 gap=1.9787 (chauffe, ignore) tap 2: pos=457.5697 gap=1.4303 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.4241 gap=2.5759 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=1.1456/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=1.1456mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 10:22:14
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 10:22:50
Part fan PASS 10:22:53
Hotend fan PASS 10:22:57
Hotend heat 220°C PASS 10:22:57
Bed heat 60°C PASS 10:23:27
Cutter (feed+cut) PASS 10:25:06
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=456.4241 gap=2.5759 (1/4) tap 3: pos=457.5697 gap=1.4303 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=1.1456/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=1.1456mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 10:25:21
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 10:28:48
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.0213 gap=1.9787 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=457.5697 gap=1.4303 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.5728/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.1401 spread=0.5728mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,340.003 is z=417.002500 probe at 49.995,340.003 is z=416.997500 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.995,340.003 is z=417.010000 Tap drift (diff=0.0125mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 49.995,340.003 is z=417.020000 Tap drift (diff=0.0100mm) — reset probe at 49.995,340.003 is z=417.032500 probe at 49.995,340.003 is z=417.037500 probe at 49.995,340.003 is z=417.040000 Tap OK (diff=0.0025mm, stable 3/5) probe at 49.995,340.003 is z=417.042500 Tap OK (diff=0.0025mm, stable 4/5) probe at 49.995,340.003 is z=417.045000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=417.0450 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 10:33:18 OK: 3 taps convergents spread=0.0025mm (tol=0.0500) sur 15 taps | taps=323.6150, 486.1850, 486.1975, 486.1625, 486.1450, 486.1400, 486.1325, 486.1400, 486.1375, 486.1375, 486.1250, 486.1425, 486.1825, 486.1550, 486.1250
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,340.003 is z=323.585000 probe at 49.998,340.003 is z=323.590000 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.998,340.003 is z=323.600000 Tap drift (diff=0.0100mm) — reset probe at 49.998,340.003 is z=323.607500 Tap OK (diff=0.0075mm, stable 2/5) probe at 49.998,340.003 is z=323.610000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 49.998,340.003 is z=323.615000 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=323.6150 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,340.003 is z=486.165000 probe at 49.998,340.003 is z=486.172500 probe at 49.998,340.003 is z=486.175000 probe at 49.998,340.003 is z=486.180000 Tap OK (diff=0.0050mm, stable 4/5) probe at 49.998,340.003 is z=486.185000 VALIDATED: trigger_z=486.1850 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,340.003 is z=486.187500 probe at 49.998,340.003 is z=486.195000 Tap OK (diff=0.0075mm, stable 4/5) probe at 49.998,340.003 is z=486.197500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=486.1975 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,340.003 is z=486.152500 probe at 49.998,340.003 is z=486.160000 Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,340.003 is z=486.162500 VALIDATED: trigger_z=486.1625 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,340.003 is z=486.137500 probe at 49.998,340.003 is z=486.142500 probe at 49.998,340.003 is z=486.140000 probe at 49.998,340.003 is z=486.145000 Tap OK (diff=0.0000mm, stable 5/5)
Screws tilt PASS 10:33:57
probe: at 54.997,315.001 bed will contact at z=1.460000 probe: at 54.997,315.001 bed will contact at z=1.462500 probe: at 54.997,315.001 bed will contact at z=1.465000 probe: at 380.001,315.001 bed will contact at z=1.427500 probe: at 380.001,315.001 bed will contact at z=1.405000 probe: at 380.001,315.001 bed will contact at z=1.417500 probe: at 380.001,83.000 bed will contact at z=1.460000 probe: at 380.001,83.000 bed will contact at z=1.480000 probe: at 380.001,83.000 bed will contact at z=1.452500 probe: at 54.997,83.000 bed will contact at z=1.405000 probe: at 54.997,83.000 bed will contact at z=1.407500 probe: at 217.505,202.498 bed will contact at z=1.360000 probe: at 217.505,202.498 bed will contact at z=1.367500 probe: at 217.505,202.498 bed will contact at z=1.370000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=285.0, z=1.46250 front right screw : x=397.0, y=285.0, z=1.41750 : adjust CCW 00:05 rear right screw : x=397.0, y=53.0, z=1.46000 : adjust CCW 00:00 rear left screw : x=72.0, y=53.0, z=1.40500 : adjust CCW 00:07 rear left screw : x=234.5, y=172.5, z=1.36750 : adjust CCW 00:11