SmartPi 1
SmartPi 2

11005C000C51353234323830

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 0281E38DE8BE
Start : 2026-07-16T07:53:55.717519 · End : 2026-07-16T08:06:27.521513 · Duration : 751 s
Received (server) : 2026-07-17T06:36:40
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 07:53:55
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=11005C000C51353234323830
Home X PASS 07:54:21
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=356.8019 gap=2.1981 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=357.1919 gap=1.8081 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 07:54:53
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3747 gap=1.6253 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.3991 gap=1.6009 (2/4) tap 4: pos=-30.3747 gap=1.6253 (3/4) tap 5: pos=-30.3991 gap=1.6009 fenetre=0.4022/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.4874 spread=0.4022mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 07:56:17
Part fan PASS 07:56:19
Hotend fan PASS 07:56:22
Hotend heat 220°C PASS 07:56:22
Bed heat 60°C PASS 07:56:22
Cutter (feed+cut) PASS 07:57:47
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=357.1919 gap=1.8081 (2/4) tap 4: pos=356.8019 gap=2.1981 (3/4) tap 5: pos=357.1919 gap=1.8081 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.0456 spread=0.3900mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3747 gap=1.6253 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7769 gap=1.2231 (2/4) tap 4: pos=-30.3991 gap=1.6009 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.7800/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.4874 spread=0.7800mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 07:58:02
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 08:00:53
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=357.1919 gap=1.8081 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.8019 gap=2.1981 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.5819 gap=1.4181 (2/4) tap 4: pos=-30.1919 gap=1.8081 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.5850/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.5819 spread=0.5850mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=395.765000 probe at 65.996,275.995 is z=288.920000 Tap drift (diff=106.8450mm) — reset probe at 65.996,275.995 is z=288.945000 Tap drift (diff=0.0250mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 65.996,275.995 is z=288.947500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 65.996,275.995 is z=288.950000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=288.9500 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 08:05:49 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9200, 385.8975, 385.9025, 385.9000, 385.9075, 385.9000, 385.9025, 385.9000, 385.9050, 385.9000, 385.9000, 385.9000, 385.8950, 385.9050, 385.9000
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=305.442500 probe at 65.999,275.995 is z=163.660000 Tap drift (diff=141.7825mm) — reset probe at 65.999,275.995 is z=114.955000 Tap drift (diff=48.7050mm) — reset probe at 65.999,275.995 is z=107.705000 Tap drift (diff=7.2500mm) — reset probe at 65.999,275.995 is z=100.825000 Tap drift (diff=6.8800mm) — reset probe at 65.999,275.995 is z=94.067500 Tap drift (diff=6.7575mm) — reset probe at 65.999,275.995 is z=70.255000 Tap drift (diff=23.8125mm) — reset probe at 65.999,275.995 is z=72.960000 Tap drift (diff=2.7050mm) — reset probe at 65.999,275.995 is z=72.210000 Tap drift (diff=0.7500mm) — reset probe at 65.999,275.995 is z=54.562500 Tap drift (diff=17.6475mm) — reset probe at 65.999,275.995 is z=0.910000 Tap drift (diff=53.6525mm) — reset probe at 65.999,275.995 is z=0.915000 Tap OK (diff=0.0050mm, stable 2/5) probe at 65.999,275.995 is z=0.920000 Tap OK (diff=0.0050mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.9200 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=385.892500 probe at 65.999,275.995 is z=385.897500 probe at 65.999,275.995 is z=385.895000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0025mm, stable 4/5) VALIDATED: trigger_z=385.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.900000 probe at 65.999,275.995 is z=385.902500
Screws tilt PASS 08:06:27
probe: at 67.000,271.004 bed will contact at z=1.132500 probe: at 67.000,271.004 bed will contact at z=1.120000 probe: at 67.000,271.004 bed will contact at z=1.087500 probe: at 267.996,271.004 bed will contact at z=0.985000 probe: at 267.996,271.004 bed will contact at z=0.975000 probe: at 267.996,271.004 bed will contact at z=0.965000 probe: at 267.996,71.995 bed will contact at z=0.970000 probe: at 267.996,71.995 bed will contact at z=0.977500 probe: at 67.000,71.995 bed will contact at z=1.005000 probe: at 67.000,71.995 bed will contact at z=0.987500 probe: at 67.000,71.995 bed will contact at z=0.947500 Probe samples exceed tolerance. Retrying... probe: at 67.000,71.995 bed will contact at z=0.927500 probe: at 67.000,71.995 bed will contact at z=0.940000 probe: at 67.000,71.995 bed will contact at z=0.995000 probe: at 67.000,71.995 bed will contact at z=1.000000 probe: at 67.000,71.995 bed will contact at z=0.965000 probe: at 67.000,71.995 bed will contact at z=0.957500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=1.12000 front right screw : x=285.0, y=241.0, z=0.97500 : adjust CCW 00:17 rear right screw : x=285.0, y=42.0, z=0.97750 : adjust CCW 00:17 rear left screw : x=84.0, y=42.0, z=0.96500 : adjust CCW 00:19