SmartPi 1
SmartPi 2

13004A000F51353135323934

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 110V · 500W · SSR SSR10DA
QC pad (MAC) : 0281D225B2A9
Start : 2026-07-30T04:24:58.936086 · End : 2026-07-30T04:37:54.428161 · Duration : 775 s
Received (server) : 2026-07-30T04:39:53
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=500 ssr=SSR10DA lot=20260618 uid=B3D7BD

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 04:24:59
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=500;ssr=SSR10DA;lot=20260618;uid=B3D7BD [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=13004A000F51353135323934
Home X PASS 04:25:24
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 04:25:59
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7769 gap=1.2231 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-30.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 04:26:15
Part fan PASS 04:26:17
Hotend fan PASS 04:26:19
Hotend heat 220°C PASS 04:26:19
Bed heat 60°C PASS 04:26:23
Cutter (feed+cut) PASS 04:27:50
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9847 gap=2.0153 (1/4) tap 3: pos=357.0091 gap=1.9909 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-30.1797 gap=1.8203 (1/4) tap 3: pos=-30.5941 gap=1.4059 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-30.1797 gap=1.8203 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.2376 spread=0.5972mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 04:28:04
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 04:30:57
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-30.7647 gap=1.2353 (1/4) tap 3: pos=-29.8141 gap=2.1859 (2/4) tap 4: pos=-30.1797 gap=1.8203 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.9506/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.1888 spread=0.9506mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) probe at 65.996,275.995 is z=395.792500 probe at 65.996,275.995 is z=398.595000 Tap rejete (vibration chassis, z=398.5950 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 65.996,275.995 is z=397.640000 Tap rejete (vibration chassis, z=397.6400 > max-z_hop) -> pas de remontee, on poursuit la descente (2) probe at 65.996,275.995 is z=397.487500 Tap rejete (vibration chassis, z=397.4875 > max-z_hop) -> pas de remontee, on poursuit la descente (3) probe at 65.996,275.995 is z=301.160000 probe at 65.996,275.995 is z=301.165000 Tap OK (diff=0.0050mm, stable 2/5) probe at 65.996,275.995 is z=301.162500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0025mm, stable 4/5) probe at 65.996,275.995 is z=301.155000 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=301.1550 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 04:37:15 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=14.9000, 385.9025, 385.8975, 385.9025, 385.9050, 385.8950, 385.9075, 385.8950, 385.8975, 385.9025, 385.9025, 385.8975, 385.9050, 385.8925, 385.9025
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=395.892500 Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (2/10) Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (3/10) Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (4/10) Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (5/10) Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (6/10) probe at 65.999,275.995 is z=398.772500 Tap rejete (vibration chassis, z=398.7725 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 65.999,275.995 is z=398.150000 Tap rejete (vibration chassis, z=398.1500 > max-z_hop) -> pas de remontee, on poursuit la descente (2) probe at 65.999,275.995 is z=397.787500 Tap rejete (vibration chassis, z=397.7875 > max-z_hop) -> pas de remontee, on poursuit la descente (3) probe at 65.999,275.995 is z=397.585000 Tap rejete (vibration chassis, z=397.5850 > max-z_hop) -> pas de remontee, on poursuit la descente (4) probe at 65.999,275.995 is z=397.390000 Tap rejete (vibration chassis, z=397.3900 > max-z_hop) -> pas de remontee, on poursuit la descente (5) probe at 65.999,275.995 is z=397.190000 Tap rejete (vibration chassis, z=397.1900 > max-z_hop) -> pas de remontee, on poursuit la descente (6) probe at 65.999,275.995 is z=397.027500 Tap rejete (vibration chassis, z=397.0275 > max-z_hop) -> pas de remontee, on poursuit la descente (7) probe at 65.999,275.995 is z=396.840000 probe at 65.999,275.995 is z=399.720000 Tap rejete (vibration chassis, z=399.7200 > max-z_hop) -> pas de remontee, on poursuit la descente (8) probe at 65.999,275.995 is z=388.592500 probe at 65.999,275.995 is z=391.475000 Tap drift (diff=2.8825mm) — reset probe at 65.999,275.995 is z=394.230000 Tap drift (diff=2.7550mm) — reset probe at 65.999,275.995 is z=397.127500 Tap rejete (vibration chassis, z=397.1275 > max-z_hop) -> pas de remontee, on poursuit la descente (9) probe at 65.999,275.995 is z=397.112500 Tap rejete (vibration chassis, z=397.1125 > max-z_hop) -> pas de remontee, on poursuit la descente (10) probe at 65.999,275.995 is z=396.665000 probe at 65.999,275.995 is z=399.542500 Tap rejete (vibration chassis, z=399.5425 > max-z_hop) -> pas de remontee, on poursuit la descente (11) probe at 65.999,275.995 is z=399.192500 Tap rejete (vibration chassis, z=399.1925 > max-z_hop) -> pas de remontee, on poursuit la descente (12)
Screws tilt PASS 04:37:54
probe: at 67.000,271.004 bed will contact at z=0.837500 probe: at 67.000,271.004 bed will contact at z=0.790000 probe: at 67.000,271.004 bed will contact at z=0.877500 Probe samples exceed tolerance. Retrying... probe: at 67.000,271.004 bed will contact at z=0.822500 probe: at 67.000,271.004 bed will contact at z=0.862500 probe: at 67.000,271.004 bed will contact at z=0.840000 probe: at 267.996,271.004 bed will contact at z=0.670000 probe: at 267.996,271.004 bed will contact at z=0.675000 probe: at 267.996,271.004 bed will contact at z=0.680000 probe: at 267.996,71.995 bed will contact at z=0.732500 probe: at 267.996,71.995 bed will contact at z=0.735000 probe: at 67.000,71.995 bed will contact at z=0.820000 probe: at 67.000,71.995 bed will contact at z=0.840000 probe: at 67.000,71.995 bed will contact at z=0.775000 probe: at 67.000,71.995 bed will contact at z=0.797500 probe: at 67.000,71.995 bed will contact at z=0.792500 probe: at 67.000,71.995 bed will contact at z=0.780000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=0.84000 front right screw : x=285.0, y=241.0, z=0.67500 : adjust CCW 00:20 rear right screw : x=285.0, y=42.0, z=0.73250 : adjust CCW 00:13 rear left screw : x=84.0, y=42.0, z=0.79250 : adjust CCW 00:06