SmartPi 1
SmartPi 2

13004F000F51353135323934

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 0281605119E6
Start : 2026-07-15T04:42:19.382823 · End : 2026-07-15T04:53:49.416805 · Duration : 690 s
Received (server) : 2026-07-15T04:53:50
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 04:42:19
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=13004F000F51353135323934
Home X PASS 04:42:45
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=357.1797 gap=1.8203 (3/4) tap 5: pos=356.8141 gap=2.1859 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 04:43:21
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 04:43:27
Part fan PASS 04:43:29
Hotend fan PASS 04:43:32
Hotend heat 220°C PASS 04:43:34
Bed heat 60°C PASS 04:43:46
Cutter (feed+cut) PASS 04:45:12
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 04:45:26
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 04:48:11
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=316.080000 probe at 65.996,275.995 is z=316.087500 Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=316.0875 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 04:53:12 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8950, 385.9050, 385.9000, 385.9025, 385.9000, 385.9175, 385.9025, 385.9000, 385.8950, 385.9075, 385.8975, 385.9025, 385.9000, 385.9000, 385.9000
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=97.360000 probe at 65.999,275.995 is z=59.462500 Tap drift (diff=37.8975mm) — reset probe at 65.999,275.995 is z=0.892500 Tap drift (diff=58.5700mm) — reset probe at 65.999,275.995 is z=0.895000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.8950 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=385.900000 probe at 65.999,275.995 is z=385.902500 Tap OK (diff=0.0000mm, stable 3/5) probe at 65.999,275.995 is z=385.905000 VALIDATED: trigger_z=385.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 4/5) VALIDATED: trigger_z=385.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) VALIDATED: trigger_z=385.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.915000 Tap drift (diff=0.0150mm) — reset Tap OK (diff=0.0025mm, stable 5/5) Tap drift (diff=0.0125mm) — reset probe at 65.999,275.995 is z=385.917500 Tap drift (diff=0.0100mm) — reset probe at 65.999,275.995 is z=385.912500 Tap OK (diff=0.0050mm, stable 3/5) VALIDATED: trigger_z=385.9175 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.885000 probe at 65.999,275.995 is z=385.887500 probe at 65.999,275.995 is z=385.892500 Tap OK (diff=0.0075mm, stable 4/5) probe at 65.999,275.995 is z=385.895000 Tap OK (diff=0.0075mm, stable 3/5) probe at 65.999,275.995 is z=385.897500
Screws tilt PASS 04:53:49
probe: at 67.000,271.004 bed will contact at z=1.380000 probe: at 67.000,271.004 bed will contact at z=1.402500 probe: at 267.996,271.004 bed will contact at z=1.495000 probe: at 267.996,271.004 bed will contact at z=1.450000 probe: at 267.996,271.004 bed will contact at z=1.420000 Probe samples exceed tolerance. Retrying... probe: at 267.996,271.004 bed will contact at z=1.472500 probe: at 267.996,271.004 bed will contact at z=1.530000 probe: at 267.996,271.004 bed will contact at z=1.520000 probe: at 267.996,271.004 bed will contact at z=1.497500 probe: at 267.996,271.004 bed will contact at z=1.525000 probe: at 267.996,71.995 bed will contact at z=1.600000 probe: at 267.996,71.995 bed will contact at z=1.642500 probe: at 267.996,71.995 bed will contact at z=1.630000 probe: at 67.000,71.995 bed will contact at z=1.452500 probe: at 67.000,71.995 bed will contact at z=1.420000 probe: at 67.000,71.995 bed will contact at z=1.432500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=1.40250 front right screw : x=285.0, y=241.0, z=1.52000 : adjust CW 00:14 rear right screw : x=285.0, y=42.0, z=1.63000 : adjust CW 00:27 rear left screw : x=84.0, y=42.0, z=1.43250 : adjust CW 00:04