| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 09:18:25 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=140040000D51353234323830
|
| Home X | PASS | 09:18:49 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.6062 gap=1.3938 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 09:19:24 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.5941 gap=1.4059 (chauffe, ignore)
tap 2: pos=-18.7769 gap=1.2231 (1/4)
tap 3: pos=-18.7769 gap=1.2231 (2/4)
tap 4: pos=-18.7891 gap=1.2109 (3/4)
tap 5: pos=-18.7647 gap=1.2353 fenetre=0.0244/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0244mm (tol=0.0500). Zero pose en butee=-18.0000
|
| Motherboard fan | PASS | 09:19:43 | |
| Part fan | PASS | 09:19:45 | |
| Hotend fan | PASS | 09:19:48 | |
| Hotend heat 220°C | PASS | 09:19:48 | |
| Bed heat 60°C | PASS | 09:21:06 | |
| Cutter (feed+cut) | PASS | 09:22:37 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.5819 gap=1.4181 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.8141 gap=2.1859 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=457.1919 gap=1.8081 fenetre=0.3778/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9999 spread=0.3778mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-18.7769 gap=1.2231 (1/4)
tap 3: pos=-18.7769 gap=1.2231 (2/4)
tap 4: pos=-18.7769 gap=1.2231 (3/4)
tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 09:22:52 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 09:26:06 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.5941 gap=1.4059 (chauffe, ignore)
tap 2: pos=457.0091 gap=1.9909 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.8019 gap=2.1981 fenetre=0.2072/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9512 spread=0.2072mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-18.7769 gap=1.2231 (1/4)
tap 3: pos=-18.7769 gap=1.2231 (2/4)
tap 4: pos=-18.7769 gap=1.2231 (3/4)
tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,339.999 is z=386.055000
probe at 49.995,339.999 is z=386.067500
Tap drift (diff=0.0125mm) — reset
probe at 49.995,339.999 is z=386.072500
Tap OK (diff=0.0050mm, stable 2/5)
probe at 49.995,339.999 is z=386.070000
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=386.0700 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 09:31:03 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1100, 486.1025, 486.1175, 486.1000, 486.1025, 486.1075, 486.0950, 486.1025, 486.1025, 486.1025, 486.1000, 486.1025, 486.1000, 486.0975, 486.1075
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,339.999 is z=379.770000
probe at 49.998,339.999 is z=372.647500
Tap drift (diff=7.1225mm) — reset
probe at 49.998,339.999 is z=357.887500
Tap drift (diff=14.7600mm) — reset
probe at 49.998,339.999 is z=1.097500
Tap drift (diff=356.7900mm) — reset
probe at 49.998,339.999 is z=1.105000
Tap OK (diff=0.0075mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
probe at 49.998,339.999 is z=1.107500
Tap OK (diff=0.0025mm, stable 4/5)
probe at 49.998,339.999 is z=1.110000
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=1.1100 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
probe at 49.998,339.999 is z=486.097500
Tap OK (diff=0.0000mm, stable 2/5)
probe at 49.998,339.999 is z=486.102500
Tap OK (diff=0.0050mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Tap OK (diff=0.0050mm, stable 2/5)
probe at 49.998,339.999 is z=486.100000
Tap OK (diff=0.0025mm, stable 3/5)
probe at 49.998,339.999 is z=486.112500
Tap drift (diff=0.0150mm) — reset
probe at 49.998,339.999 is z=486.115000
probe at 49.998,339.999 is z=486.117500
VALIDATED: trigger_z=486.1175 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,339.999 is z=486.082500
probe at 49.998,339.999 is z=486.095000
Tap OK (diff=0.0050mm, stable 5/5)
VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,339.999 is z=486.107500
Tap OK (diff=0.0075mm, stable 4/5)
probe at 49.998,339.999 is z=486.105000
|
| Screws tilt | PASS | 09:31:45 |
probe: at 54.997,328.001 bed will contact at z=1.930000
probe: at 54.997,328.001 bed will contact at z=1.945000
probe: at 54.997,328.001 bed will contact at z=1.947500
probe: at 380.001,328.001 bed will contact at z=1.885000
probe: at 380.001,328.001 bed will contact at z=1.867500
probe: at 380.001,328.001 bed will contact at z=1.842500
probe: at 380.001,101.996 bed will contact at z=1.887500
probe: at 380.001,101.996 bed will contact at z=1.847500
probe: at 380.001,101.996 bed will contact at z=1.812500
Probe samples exceed tolerance. Retrying...
probe: at 380.001,101.996 bed will contact at z=1.795000
probe: at 380.001,101.996 bed will contact at z=1.787500
probe: at 380.001,101.996 bed will contact at z=1.807500
probe: at 54.997,101.996 bed will contact at z=1.897500
probe: at 54.997,101.996 bed will contact at z=1.895000
probe: at 217.505,214.498 bed will contact at z=2.010000
probe: at 217.505,214.498 bed will contact at z=2.000000
probe: at 217.505,214.498 bed will contact at z=1.997500
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=298.0, z=1.94500
front right screw : x=397.0, y=298.0, z=1.86750 : adjust CCW 00:09
rear right screw : x=397.0, y=72.0, z=1.79500 : adjust CCW 00:18
rear left screw : x=72.0, y=72.0, z=1.89750 : adjust CCW 00:06
middle : x=234.5, y=184.5, z=2.00000 : adjust CW 00:07
|