← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

160044000D51353234323830

PASS Grade A Grade B
Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 02813B23751D
Start : 2026-06-29T09:06:29.621518 · End : 2026-06-29T09:17:10.200447 · Duration : 640 s
Received (server) : 2026-06-30T01:57:34
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 09:06:29
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=160044000D51353234323830
Home X PASS 09:06:51
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 09:07:21
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 09:08:15
Part fan PASS 09:08:18
Hotend fan PASS 09:08:20
Hotend heat 220°C PASS 09:08:20
Bed heat 60°C PASS 09:08:29
Cutter (feed+cut) PASS 09:09:51
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 09:10:02
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 09:12:38
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7891 gap=1.2109 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=265.825000 probe at 31.003,211.998 is z=175.980000 Tap drift (diff=89.8450mm) — reset probe at 31.003,211.998 is z=176.187500 Tap drift (diff=0.2075mm) — reset probe at 31.003,211.998 is z=176.185000 Tap OK (diff=0.0025mm, stable 2/5) probe at 31.003,211.998 is z=176.182500 Tap OK (diff=0.0025mm, stable 3/5) probe at 31.003,211.998 is z=176.180000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=176.1800 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 09:16:46 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8825, 255.8800, 255.8925, 255.9000, 255.8975, 255.9000, 255.8950, 255.8975, 255.8975, 255.8975, 255.8975, 255.8975, 255.8975, 255.9000, 255.8975
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=265.742500 probe at 30.994,211.998 is z=267.457500 Tap rejete (vibration chassis, z=267.4575 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 30.994,211.998 is z=260.700000 probe at 30.994,211.998 is z=0.725000 Tap drift (diff=259.9750mm) — reset probe at 30.994,211.998 is z=3.615000 Tap drift (diff=2.8900mm) — reset Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (2/10) probe at 30.994,211.998 is z=0.887500 Tap drift (diff=2.7275mm) — reset Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 30.994,211.998 is z=0.885000 Tap OK (diff=0.0025mm, stable 4/5) probe at 30.994,211.998 is z=0.882500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=0.8825 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.907500 probe at 30.994,211.998 is z=255.905000 Tap OK (diff=0.0025mm, stable 2/5) probe at 30.994,211.998 is z=255.885000 Tap drift (diff=0.0200mm) — reset probe at 30.994,211.998 is z=255.880000 Tap OK (diff=0.0050mm, stable 2/5) probe at 30.994,211.998 is z=255.877500 VALIDATED: trigger_z=255.8800 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.895000 probe at 30.994,211.998 is z=255.892500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=255.8925 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.900000 VALIDATED: trigger_z=255.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Screws tilt PASS 09:17:10
probe: at 32.495,205.497 bed will contact at z=1.695000 probe: at 32.495,205.497 bed will contact at z=1.675000 probe: at 32.495,205.497 bed will contact at z=1.665000 probe: at 206.996,205.497 bed will contact at z=2.907500 probe: at 206.996,205.497 bed will contact at z=2.915000 probe: at 206.996,205.497 bed will contact at z=2.922500 probe: at 206.996,31.995 bed will contact at z=4.655000 probe: at 206.996,31.995 bed will contact at z=4.612500 probe: at 206.996,31.995 bed will contact at z=4.637500 probe: at 32.495,31.995 bed will contact at z=4.220000 probe: at 32.495,31.995 bed will contact at z=4.235000 probe: at 32.495,31.995 bed will contact at z=4.192500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=1.67500 front right screw : x=224.0, y=175.5, z=2.91500 : adjust CW 02:29 rear right screw : x=224.0, y=2.0, z=4.63750 : adjust CW 05:56 rear left screw : x=49.5, y=2.0, z=4.22000 : adjust CW 05:05