← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

180051000C51353234323830

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 0281D225B2A9
Start : 2026-10-23T02:39:15.728419 · End : 2026-10-23T02:53:43.344117 · Duration : 867 s
Received (server) : 2026-10-23T02:56:11
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 02:39:15
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=180051000C51353234323830
Home X PASS 02:39:41
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 02:40:13
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.6062 gap=1.3938 (chauffe, ignore) tap 2: pos=-29.9847 gap=2.0153 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9938 spread=0.0122mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 02:42:12
Part fan PASS 02:42:14
Hotend fan PASS 02:42:16
Hotend heat 220°C PASS 02:42:16
Bed heat 60°C PASS 02:42:16
Cutter (feed+cut) PASS 02:43:50
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 02:44:09
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 100mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 02:47:35
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=395.622500 probe at 65.996,275.995 is z=294.775000 Tap drift (diff=100.8475mm) — reset probe at 65.996,275.995 is z=294.822500 Tap drift (diff=0.0475mm) — reset probe at 65.996,275.995 is z=297.597500 Tap drift (diff=2.7750mm) — reset probe at 65.996,275.995 is z=294.850000 Tap drift (diff=2.7475mm) — reset probe at 65.996,275.995 is z=294.855000 Tap OK (diff=0.0050mm, stable 2/5) probe at 65.996,275.995 is z=294.852500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=294.8525 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 02:53:13 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.5925, 386.1075, 386.1025, 386.1050, 386.0975, 386.1050, 386.0975, 386.1000, 386.1075, 386.0950, 386.1075, 386.1050, 386.1075, 386.0925, 386.1075
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=395.317500 probe at 65.999,275.995 is z=322.440000 Tap drift (diff=72.8775mm) — reset probe at 65.999,275.995 is z=1.520000 Tap drift (diff=320.9200mm) — reset probe at 65.999,275.995 is z=1.557500 Tap drift (diff=0.0375mm) — reset probe at 65.999,275.995 is z=4.330000 Tap drift (diff=2.7725mm) — reset probe at 65.999,275.995 is z=1.592500 Tap drift (diff=2.7375mm) — reset probe at 65.999,275.995 is z=1.595000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=1.5925 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=386.102500 probe at 65.999,275.995 is z=386.110000 Tap OK (diff=0.0075mm, stable 2/5) probe at 65.999,275.995 is z=386.107500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=386.1075 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 65.999,275.995 is z=386.097500 probe at 65.999,275.995 is z=386.100000 Tap OK (diff=0.0000mm, stable 3/5) probe at 65.999,275.995 is z=386.105000 Tap OK (diff=0.0050mm, stable 4/5) VALIDATED: trigger_z=386.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 65.999,275.995 is z=386.090000 Tap drift (diff=0.0100mm) — reset Tap OK (diff=0.0000mm, stable 2/5) VALIDATED: trigger_z=386.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 65.999,275.995 is z=386.092500 Tap OK (diff=0.0050mm, stable 5/5)
Screws tilt PASS 02:53:43
probe: at 67.000,271.004 bed will contact at z=1.697500 probe: at 67.000,271.004 bed will contact at z=1.705000 probe: at 267.996,271.004 bed will contact at z=1.725000 probe: at 267.996,271.004 bed will contact at z=1.717500 probe: at 267.996,271.004 bed will contact at z=1.730000 probe: at 267.996,71.995 bed will contact at z=1.555000 probe: at 267.996,71.995 bed will contact at z=1.565000 probe: at 267.996,71.995 bed will contact at z=1.557500 probe: at 67.000,71.995 bed will contact at z=1.632500 probe: at 67.000,71.995 bed will contact at z=1.622500 probe: at 67.000,71.995 bed will contact at z=1.665000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=1.69750 front right screw : x=285.0, y=241.0, z=1.72500 : adjust CW 00:03 rear right screw : x=285.0, y=42.0, z=1.55750 : adjust CCW 00:17 rear left screw : x=84.0, y=42.0, z=1.63250 : adjust CCW 00:08