← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

190040000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 02817A147AB3
Start : 2026-08-11T07:02:40.044653 · End : 2026-08-11T07:17:49.019554 · Duration : 908 s
Received (server) : 2026-08-12T02:06:04
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 07:02:40
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=190040000D51353234323830
Home X PASS 07:03:06
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 07:03:48
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1 rejete: aucun contact sur 7.0mm (No trigger on probe after full movement) tap 2 rejete: aucun contact sur 7.0mm (No trigger on probe after full movement) YUMI_SENSORLESS_HOME Y: home de base suspect (pas de contact) -> re-home de recuperation 1/2 tap 3: pos=-18.7769 gap=1.2231 (chauffe, ignore) tap 4: pos=-18.3991 gap=1.6009 (1/4) tap 5: pos=-18.3747 gap=1.6253 (2/4) tap 6: pos=-18.7769 gap=1.2231 (3/4) tap 7: pos=-18.7769 gap=1.2231 fenetre=0.4022/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (2 rejetes) -> moyenne=-18.5819 spread=0.4022mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 07:03:52
Part fan PASS 07:03:55
Hotend fan PASS 07:03:57
Hotend heat 220°C PASS 07:03:57
Bed heat 60°C PASS 07:07:06
Cutter (feed+cut) PASS 07:08:39
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1 rejete: aucun contact sur 7.0mm (No trigger on probe after full movement) tap 2 rejete: cible atteinte sans buter (gap=0.6869) YUMI_SENSORLESS_HOME Y: home de base suspect (pas de contact) -> re-home de recuperation 1/2 tap 3: pos=-18.7891 gap=1.2109 (chauffe, ignore) tap 4: pos=-18.7647 gap=1.2353 (1/4) tap 5: pos=-18.3991 gap=1.6009 (2/4) tap 6: pos=-18.3869 gap=1.6131 (3/4) tap 7: pos=-18.7647 gap=1.2353 fenetre=0.3778/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (2 rejetes) -> moyenne=-18.5788 spread=0.3778mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 07:08:54
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 07:12:16
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1 rejete: aucun contact sur 7.0mm (No trigger on probe after full movement) tap 2: pos=-18.8987 gap=1.1013 (chauffe, ignore) tap 3: pos=-18.7769 gap=1.2231 (1/4) tap 4: pos=-18.7769 gap=1.2231 (2/4) tap 5: pos=-18.7769 gap=1.2231 (3/4) tap 6: pos=-18.5941 gap=1.4059 fenetre=0.1828/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (1 rejetes) -> moyenne=-18.7312 spread=0.1828mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=410.380000 probe at 49.995,339.999 is z=410.385000 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.995,339.999 is z=410.387500 Tap OK (diff=0.0025mm, stable 3/5) probe at 49.995,339.999 is z=410.392500 Tap OK (diff=0.0050mm, stable 4/5) Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=410.3875 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 07:17:09 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1025, 486.1025, 486.1050, 486.1025, 486.1050, 486.1000, 486.1025, 486.1000, 486.1000, 486.1025, 486.1000, 486.1000, 486.1000, 486.1025, 486.1025
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=495.785000 probe at 49.998,339.999 is z=498.442500 Tap rejete (vibration chassis, z=498.4425 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 49.998,339.999 is z=498.267500 Tap rejete (vibration chassis, z=498.2675 > max-z_hop) -> pas de remontee, on poursuit la descente (2) probe at 49.998,339.999 is z=498.095000 Tap rejete (vibration chassis, z=498.0950 > max-z_hop) -> pas de remontee, on poursuit la descente (3) probe at 49.998,339.999 is z=498.037500 Tap rejete (vibration chassis, z=498.0375 > max-z_hop) -> pas de remontee, on poursuit la descente (4) probe at 49.998,339.999 is z=497.877500 Tap rejete (vibration chassis, z=497.8775 > max-z_hop) -> pas de remontee, on poursuit la descente (5) probe at 49.998,339.999 is z=497.712500 Tap rejete (vibration chassis, z=497.7125 > max-z_hop) -> pas de remontee, on poursuit la descente (6) probe at 49.998,339.999 is z=497.542500 Tap rejete (vibration chassis, z=497.5425 > max-z_hop) -> pas de remontee, on poursuit la descente (7) probe at 49.998,339.999 is z=497.485000 Tap rejete (vibration chassis, z=497.4850 > max-z_hop) -> pas de remontee, on poursuit la descente (8) probe at 49.998,339.999 is z=497.317500 Tap rejete (vibration chassis, z=497.3175 > max-z_hop) -> pas de remontee, on poursuit la descente (9) probe at 49.998,339.999 is z=497.155000 Tap rejete (vibration chassis, z=497.1550 > max-z_hop) -> pas de remontee, on poursuit la descente (10) probe at 49.998,339.999 is z=496.992500 probe at 49.998,339.999 is z=499.662500 Tap rejete (vibration chassis, z=499.6625 > max-z_hop) -> pas de remontee, on poursuit la descente (11) probe at 49.998,339.999 is z=499.597500 Tap rejete (vibration chassis, z=499.5975 > max-z_hop) -> pas de remontee, on poursuit la descente (12) probe at 49.998,339.999 is z=499.430000 Tap rejete (vibration chassis, z=499.4300 > max-z_hop) -> pas de remontee, on poursuit la descente (13) probe at 49.998,339.999 is z=142.160000 probe at 49.998,339.999 is z=71.487500 Tap drift (diff=70.6725mm) — reset probe at 49.998,339.999 is z=73.250000 Tap drift (diff=1.7625mm) — reset probe at 49.998,339.999 is z=1.092500 Tap drift (diff=72.1575mm) — reset probe at 49.998,339.999 is z=1.102500 Tap drift (diff=0.0100mm) — reset Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
Screws tilt PASS 07:17:49
probe: at 54.997,328.001 bed will contact at z=1.500000 probe: at 54.997,328.001 bed will contact at z=1.487500 probe: at 54.997,328.001 bed will contact at z=1.502500 probe: at 380.001,328.001 bed will contact at z=1.560000 probe: at 380.001,328.001 bed will contact at z=1.567500 probe: at 380.001,328.001 bed will contact at z=1.575000 probe: at 380.001,101.996 bed will contact at z=1.437500 probe: at 380.001,101.996 bed will contact at z=1.470000 probe: at 380.001,101.996 bed will contact at z=1.435000 probe: at 54.997,101.996 bed will contact at z=1.445000 probe: at 54.997,101.996 bed will contact at z=1.462500 probe: at 217.505,214.498 bed will contact at z=1.570000 probe: at 217.505,214.498 bed will contact at z=1.572500 probe: at 217.505,214.498 bed will contact at z=1.577500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.50000 front right screw : x=397.0, y=298.0, z=1.56750 : adjust CW 00:08 rear right screw : x=397.0, y=72.0, z=1.43750 : adjust CCW 00:07 rear left screw : x=72.0, y=72.0, z=1.44500 : adjust CCW 00:07 middle : x=234.5, y=184.5, z=1.57250 : adjust CW 00:09