| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 02:12:52 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=19005E000C51353234323830
|
| Home X | PASS | 02:13:19 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.6062 gap=1.3938 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 02:13:55 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
|
| Motherboard fan | PASS | 02:14:01 | |
| Part fan | PASS | 02:14:03 | |
| Hotend fan | PASS | 02:14:05 | |
| Hotend heat 220°C | PASS | 02:14:08 | |
| Bed heat 60°C | PASS | 02:14:20 | |
| Cutter (feed+cut) | PASS | 02:16:43 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.6062 gap=1.3938 (chauffe, ignore)
tap 2: pos=456.9847 gap=2.0153 (1/4)
tap 3: pos=457.0091 gap=1.9909 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9847 gap=2.0153 fenetre=0.0244/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9938 spread=0.0244mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 02:16:57 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 02:19:22 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.5941 gap=1.4059 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=457.0091 gap=1.9909 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9847 gap=2.0153 fenetre=0.0244/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.0091 gap=1.9909 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,339.999 is z=486.237500
probe at 49.995,339.999 is z=443.247500
Tap drift (diff=42.9900mm) — reset
probe at 49.995,339.999 is z=411.835000
Tap drift (diff=31.4125mm) — reset
probe at 49.995,339.999 is z=411.937500
Tap drift (diff=0.1025mm) — reset
probe at 49.995,339.999 is z=411.950000
Tap drift (diff=0.0125mm) — reset
probe at 49.995,339.999 is z=411.940000
Tap OK (diff=0.0100mm, stable 2/5)
Tap drift (diff=0.0100mm) — reset
probe at 49.995,339.999 is z=411.955000
Tap OK (diff=0.0050mm, stable 2/5)
probe at 49.995,339.999 is z=411.952500
Tap OK (diff=0.0025mm, stable 3/5)
probe at 49.995,339.999 is z=411.947500
Tap OK (diff=0.0050mm, stable 4/5)
Tap OK (diff=0.0050mm, stable 5/5)
VALIDATED: trigger_z=411.9525 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
|
| Z tap repeatability | PASS | 02:24:28 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0175, 486.1000, 486.0975, 486.1050, 486.1000, 486.1025, 486.0975, 486.1025, 486.1000, 486.1050, 486.0975, 486.1000, 486.1000, 486.1025, 486.1000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,339.999 is z=361.950000
probe at 49.998,339.999 is z=355.140000
Tap drift (diff=6.8100mm) — reset
probe at 49.998,339.999 is z=328.357500
Tap drift (diff=26.7825mm) — reset
probe at 49.998,339.999 is z=331.342500
Tap drift (diff=2.9850mm) — reset
probe at 49.998,339.999 is z=333.322500
Tap drift (diff=1.9800mm) — reset
probe at 49.998,339.999 is z=245.707500
Tap drift (diff=87.6150mm) — reset
probe at 49.998,339.999 is z=186.655000
Tap drift (diff=59.0525mm) — reset
probe at 49.998,339.999 is z=142.522500
Tap drift (diff=44.1325mm) — reset
probe at 49.998,339.999 is z=13.152500
Tap drift (diff=129.3700mm) — reset
probe at 49.998,339.999 is z=0.980000
Tap drift (diff=12.1725mm) — reset
probe at 49.998,339.999 is z=0.995000
Tap drift (diff=0.0150mm) — reset
probe at 49.998,339.999 is z=1.012500
Tap drift (diff=0.0175mm) — reset
probe at 49.998,339.999 is z=1.017500
Tap OK (diff=0.0050mm, stable 2/5)
probe at 49.998,339.999 is z=1.015000
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=1.0175 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
probe at 49.998,339.999 is z=486.072500
probe at 49.998,339.999 is z=486.102500
Tap drift (diff=0.0300mm) — reset
probe at 49.998,339.999 is z=486.105000
Tap OK (diff=0.0025mm, stable 2/5)
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
|
| Screws tilt | PASS | 02:25:19 |
probe: at 54.997,328.001 bed will contact at z=1.140000
probe: at 54.997,328.001 bed will contact at z=1.190000
Probe samples exceed tolerance. Retrying...
probe: at 54.997,328.001 bed will contact at z=1.192500
probe: at 54.997,328.001 bed will contact at z=1.205000
probe: at 380.001,328.001 bed will contact at z=1.267500
probe: at 380.001,328.001 bed will contact at z=1.272500
probe: at 380.001,328.001 bed will contact at z=1.237500
probe: at 380.001,101.996 bed will contact at z=1.290000
probe: at 380.001,101.996 bed will contact at z=1.277500
probe: at 380.001,101.996 bed will contact at z=1.342500
probe: at 380.001,101.996 bed will contact at z=1.305000
probe: at 380.001,101.996 bed will contact at z=1.347500
probe: at 380.001,101.996 bed will contact at z=1.335000
probe: at 380.001,101.996 bed will contact at z=1.257500
probe: at 380.001,101.996 bed will contact at z=1.255000
probe: at 380.001,101.996 bed will contact at z=1.260000
probe: at 380.001,101.996 bed will contact at z=1.252500
probe: at 54.997,101.996 bed will contact at z=1.215000
probe: at 54.997,101.996 bed will contact at z=1.257500
probe: at 54.997,101.996 bed will contact at z=1.252500
probe: at 217.505,214.498 bed will contact at z=1.260000
probe: at 217.505,214.498 bed will contact at z=1.270000
probe: at 217.505,214.498 bed will contact at z=1.277500
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=298.0, z=1.19250
front right screw : x=397.0, y=298.0, z=1.26750 : adjust CW 00:09
rear right screw : x=397.0, y=72.0, z=1.25500 : adjust CW 00:08
rear left screw : x=72.0, y=72.0, z=1.25250 : adjust CW 00:07
middle : x=234.5, y=184.5, z=1.27000 : adjust CW 00:09
|