SmartPi 1
SmartPi 2

1C0044000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 028103694A6F
Start : 2026-08-17T09:16:50.179821 · End : 2026-08-17T09:28:44.270194 · Duration : 714 s
Received (server) : 2026-08-17T01:32:41
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 09:16:50
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=1C0044000D51353234323830
Home X PASS 09:17:16
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=467.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=466.9969 gap=2.0031 (1/4) tap 3: pos=466.9969 gap=2.0031 (2/4) tap 4: pos=467.0091 gap=1.9909 (3/4) tap 5: pos=466.9969 gap=2.0031 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=466.9999 spread=0.0122mm (tol=0.0500). Zero pose en butee=467.0000
Home Y PASS 09:17:52
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-20.9847 gap=2.0153 (chauffe, ignore) tap 2: pos=-20.9969 gap=2.0031 (1/4) tap 3: pos=-20.9969 gap=2.0031 (2/4) tap 4: pos=-20.9969 gap=2.0031 (3/4) tap 5: pos=-20.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-20.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-21.0000
Motherboard fan PASS 09:18:07
Part fan PASS 09:18:09
Hotend fan PASS 09:18:11
Hotend heat 220°C PASS 09:18:15
Bed heat 60°C PASS 09:18:54
Cutter (feed+cut) PASS 09:20:26
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=467.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=467.0091 gap=1.9909 (1/4) tap 3: pos=466.9847 gap=2.0153 (2/4) tap 4: pos=466.9969 gap=2.0031 (3/4) tap 5: pos=466.9969 gap=2.0031 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=466.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=467.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-20.9847 gap=2.0153 (chauffe, ignore) tap 2: pos=-20.9969 gap=2.0031 (1/4) tap 3: pos=-20.9969 gap=2.0031 (2/4) tap 4: pos=-20.9969 gap=2.0031 (3/4) tap 5: pos=-20.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-20.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-21.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 09:20:41
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 09:23:16
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=467.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=466.9969 gap=2.0031 (1/4) tap 3: pos=466.9969 gap=2.0031 (2/4) tap 4: pos=466.9969 gap=2.0031 (3/4) tap 5: pos=467.0091 gap=1.9909 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=466.9999 spread=0.0122mm (tol=0.0500). Zero pose en butee=467.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-20.9847 gap=2.0153 (chauffe, ignore) tap 2: pos=-20.9969 gap=2.0031 (1/4) tap 3: pos=-20.9969 gap=2.0031 (2/4) tap 4: pos=-20.9969 gap=2.0031 (3/4) tap 5: pos=-20.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-20.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-21.0000 Moving to tap point X=56.0 Y=334.0... Probing with pressure switch... probe at 55.998,334.001 is z=409.192500 probe at 55.998,334.001 is z=409.215000 Tap drift (diff=0.0225mm) — reset Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 55.998,334.001 is z=409.220000 Tap OK (diff=0.0050mm, stable 4/5) probe at 55.998,334.001 is z=409.217500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=409.2175 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (56.0, 334.0) ~ point de tap (56.0, 334.0) Z calibration complete!
Z tap repeatability PASS 09:28:04 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0925, 486.1125, 486.1025, 486.1025, 486.1000, 486.1025, 486.1025, 486.1025, 486.1000, 486.1025, 486.1000, 486.1025, 486.1000, 486.1000, 486.1025
Moving to tap point X=56.0 Y=334.0... Probing with pressure switch... probe at 56.001,334.001 is z=1.070000 probe at 56.001,334.001 is z=1.087500 Tap drift (diff=0.0175mm) — reset probe at 56.001,334.001 is z=1.090000 Tap OK (diff=0.0025mm, stable 2/5) probe at 56.001,334.001 is z=1.092500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=1.0925 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (56.0, 334.0) ~ point de tap (56.0, 334.0) Z calibration complete! probe at 56.001,334.001 is z=486.092500 probe at 56.001,334.001 is z=486.107500 Tap drift (diff=0.0150mm) — reset Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 56.001,334.001 is z=486.110000 Tap OK (diff=0.0025mm, stable 4/5) probe at 56.001,334.001 is z=486.112500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=486.1125 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 56.001,334.001 is z=486.082500 probe at 56.001,334.001 is z=486.097500 probe at 56.001,334.001 is z=486.100000 probe at 56.001,334.001 is z=486.102500 VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 56.001,334.001 is z=486.085000 VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 56.001,334.001 is z=486.090000 Tap drift (diff=0.0100mm) — reset Tap OK (diff=0.0075mm, stable 2/5) Tap drift (diff=0.0125mm) — reset probe at 56.001,334.001 is z=486.105000 Tap OK (diff=0.0050mm, stable 3/5) Tap OK (diff=0.0050mm, stable 4/5) probe at 56.001,334.001 is z=486.087500 Tap OK (diff=0.0050mm, stable 2/5)
Screws tilt PASS 09:28:44
probe: at 56.003,334.994 bed will contact at z=1.557500 probe: at 56.003,334.994 bed will contact at z=1.635000 Probe samples exceed tolerance. Retrying... probe: at 56.003,334.994 bed will contact at z=1.640000 probe: at 56.003,334.994 bed will contact at z=1.697500 probe: at 56.003,334.994 bed will contact at z=1.642500 probe: at 56.003,334.994 bed will contact at z=1.657500 probe: at 56.003,334.994 bed will contact at z=1.675000 probe: at 388.002,334.994 bed will contact at z=1.555000 probe: at 388.002,334.994 bed will contact at z=1.580000 probe: at 388.002,334.994 bed will contact at z=1.577500 probe: at 388.002,110.001 bed will contact at z=1.622500 probe: at 388.002,110.001 bed will contact at z=1.625000 probe: at 56.003,110.001 bed will contact at z=1.875000 probe: at 56.003,110.001 bed will contact at z=1.850000 probe: at 56.003,110.001 bed will contact at z=1.847500 probe: at 221.996,222.004 bed will contact at z=1.487500 probe: at 221.996,222.004 bed will contact at z=1.495000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=73.0, y=305.0, z=1.65750 front right screw : x=405.0, y=305.0, z=1.57750 : adjust CCW 00:10 rear right screw : x=405.0, y=80.0, z=1.62500 : adjust CCW 00:04 rear left screw : x=73.0, y=80.0, z=1.85000 : adjust CW 00:23 rear middle screw : x=239.0, y=192.0, z=1.48750 : adjust CCW 00:20