| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 02:11:16 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=1F003F000D51353234323830
|
| Home X | PASS | 02:11:38 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.7525 gap=1.2475 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 02:12:12 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.3747 gap=1.6253 (chauffe, ignore)
tap 2: pos=-18.3991 gap=1.6009 (1/4)
tap 3: pos=-18.3747 gap=1.6253 (2/4)
tap 4: pos=-18.3991 gap=1.6009 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.4022/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.2924 spread=0.4022mm (tol=0.0500). Zero pose en butee=-18.0000
|
| Motherboard fan | PASS | 02:12:44 | |
| Part fan | PASS | 02:12:46 | |
| Hotend fan | PASS | 02:12:48 | |
| Hotend heat 220°C | PASS | 02:12:48 | |
| Bed heat 60°C | PASS | 02:12:48 | |
| Cutter (feed+cut) | PASS | 02:14:19 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.3991 gap=1.6009 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.3747 gap=1.6253 (chauffe, ignore)
tap 2: pos=-18.3991 gap=1.6009 (1/4)
tap 3: pos=-18.3747 gap=1.6253 (2/4)
tap 4: pos=-18.3991 gap=1.6009 (3/4)
tap 5: pos=-18.3747 gap=1.6253 fenetre=0.0244/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.3869 spread=0.0244mm (tol=0.0500). Zero pose en butee=-18.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 02:14:33 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 02:17:41 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.3991 gap=1.6009 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.1919 gap=1.8081 (chauffe, ignore)
tap 2: pos=-18.7769 gap=1.2231 (1/4)
tap 3: pos=-18.5819 gap=1.4181 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-18.1919 gap=1.8081 fenetre=0.7800/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.3869 spread=0.7800mm (tol=0.0500). Zero pose en butee=-18.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,339.999 is z=391.697500
probe at 49.995,339.999 is z=391.705000
Tap OK (diff=0.0075mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
probe at 49.995,339.999 is z=391.707500
Tap OK (diff=0.0025mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=391.7075 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 02:22:39 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1375, 486.1025, 486.1000, 486.1000, 486.1050, 486.1000, 486.1025, 486.1000, 486.1025, 486.1025, 486.0975, 486.0950, 486.1025, 486.1000, 486.1050
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,339.999 is z=495.750000
probe at 49.998,339.999 is z=413.245000
Tap drift (diff=82.5050mm) — reset
probe at 49.998,339.999 is z=339.735000
Tap drift (diff=73.5100mm) — reset
probe at 49.998,339.999 is z=337.357500
Tap drift (diff=2.3775mm) — reset
probe at 49.998,339.999 is z=338.972500
Tap drift (diff=1.6150mm) — reset
probe at 49.998,339.999 is z=1.125000
Tap drift (diff=337.8475mm) — reset
probe at 49.998,339.999 is z=1.135000
Tap drift (diff=0.0100mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
probe at 49.998,339.999 is z=1.137500
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=1.1375 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
probe at 49.998,339.999 is z=486.095000
probe at 49.998,339.999 is z=486.102500
Tap OK (diff=0.0075mm, stable 2/5)
probe at 49.998,339.999 is z=486.100000
Tap OK (diff=0.0025mm, stable 4/5)
VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Tap OK (diff=0.0000mm, stable 3/5)
probe at 49.998,339.999 is z=486.105000
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,339.999 is z=486.092500
probe at 49.998,339.999 is z=486.097500
probe at 49.998,339.999 is z=486.110000
Tap drift (diff=0.0125mm) — reset
Tap OK (diff=0.0025mm, stable 2/5)
Tap OK (diff=0.0050mm, stable 2/5)
|
| Screws tilt | PASS | 02:23:17 |
probe: at 54.997,328.001 bed will contact at z=1.905000
probe: at 54.997,328.001 bed will contact at z=1.900000
probe: at 380.001,328.001 bed will contact at z=1.812500
probe: at 380.001,328.001 bed will contact at z=1.815000
probe: at 380.001,328.001 bed will contact at z=1.817500
probe: at 380.001,101.996 bed will contact at z=1.580000
probe: at 380.001,101.996 bed will contact at z=1.587500
probe: at 380.001,101.996 bed will contact at z=1.590000
probe: at 54.997,101.996 bed will contact at z=1.752500
probe: at 54.997,101.996 bed will contact at z=1.760000
probe: at 54.997,101.996 bed will contact at z=1.757500
probe: at 217.505,214.498 bed will contact at z=1.847500
probe: at 217.505,214.498 bed will contact at z=1.817500
probe: at 217.505,214.498 bed will contact at z=1.855000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=298.0, z=1.90500
front right screw : x=397.0, y=298.0, z=1.81500 : adjust CCW 00:11
rear right screw : x=397.0, y=72.0, z=1.58750 : adjust CCW 00:38
rear left screw : x=72.0, y=72.0, z=1.75750 : adjust CCW 00:18
middle : x=234.5, y=184.5, z=1.84750 : adjust CCW 00:07
|
Moves this report to the trash — you can restore it from /trash.