← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

200040000D51353234323830

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 02810E70DC29
Start : 2026-06-18T09:02:01.319773 · End : 2026-06-18T09:14:45.722753 · Duration : 764 s
Received (server) : 2026-06-18T09:10:22
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 09:02:01
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=200040000D51353234323830
Home X PASS 09:02:22
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 09:02:45
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 09:04:22
Part fan PASS 09:04:24
Hotend fan PASS 09:04:36
Hotend heat 220°C PASS 09:04:36
Bed heat 60°C PASS 09:04:36
Cutter (feed+cut) PASS 09:06:14
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=357.1797 gap=1.8203 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.1828/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.0426 spread=0.1828mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 09:06:45
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 175mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 09:09:44
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.9475 gap=1.0525 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.8141 gap=2.1859 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=357.1797 gap=1.8203 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=389.370000 probe at 65.996,275.995 is z=389.760000 Tap drift (diff=0.3900mm) — reset probe at 65.996,275.995 is z=257.412500 Tap drift (diff=132.3475mm) — reset probe at 65.996,275.995 is z=187.347500 Tap drift (diff=70.0650mm) — reset probe at 65.996,275.995 is z=187.377500 Tap drift (diff=0.0300mm) — reset probe at 65.996,275.995 is z=187.392500 Tap drift (diff=0.0150mm) — reset probe at 65.996,275.995 is z=187.402500 Tap OK (diff=0.0100mm, stable 2/5) probe at 65.996,275.995 is z=187.427500 Tap drift (diff=0.0250mm) — reset probe at 65.996,275.995 is z=187.437500 probe at 65.996,275.995 is z=187.460000 Tap drift (diff=0.0225mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 65.996,275.995 is z=187.470000 Tap OK (diff=0.0100mm, stable 3/5)
Z tap repeatability PASS 09:14:18 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9325, 385.9725, 385.9050, 385.9025, 385.8975, 385.9025, 385.9025, 385.9000, 385.9025, 385.8975, 385.9050, 385.9000, 385.9000, 385.9025, 385.8975
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=395.762500 probe at 65.999,275.995 is z=398.515000 Tap rejete (vibration chassis, z=398.5150 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 65.999,275.995 is z=397.040000 Tap rejete (vibration chassis, z=397.0400 > max-z_hop) -> pas de remontee, on poursuit la descente (2) probe at 65.999,275.995 is z=304.920000 probe at 65.999,275.995 is z=0.770000 Tap drift (diff=304.1500mm) — reset probe at 65.999,275.995 is z=0.845000 Tap drift (diff=0.0750mm) — reset probe at 65.999,275.995 is z=0.860000 Tap drift (diff=0.0150mm) — reset probe at 65.999,275.995 is z=0.897500 Tap drift (diff=0.0375mm) — reset probe at 65.999,275.995 is z=0.920000 Tap drift (diff=0.0225mm) — reset probe at 65.999,275.995 is z=0.927500 Tap OK (diff=0.0075mm, stable 2/5) probe at 65.999,275.995 is z=0.922500 Tap OK (diff=0.0050mm, stable 3/5) probe at 65.999,275.995 is z=0.925000 Tap OK (diff=0.0025mm, stable 4/5) probe at 65.999,275.995 is z=0.932500 Tap OK (diff=0.0075mm, stable 5/5) VALIDATED: trigger_z=0.9325 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=385.962500 probe at 65.999,275.995 is z=385.975000 Tap drift (diff=0.0125mm) — reset Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 65.999,275.995 is z=385.967500 Tap OK (diff=0.0075mm, stable 4/5) probe at 65.999,275.995 is z=385.972500 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=385.9725 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.900000
Screws tilt PASS 09:14:45
probe: at 67.000,271.004 bed will contact at z=1.600000 probe: at 67.000,271.004 bed will contact at z=1.642500 probe: at 67.000,271.004 bed will contact at z=1.640000 probe: at 267.996,271.004 bed will contact at z=1.612500 probe: at 267.996,271.004 bed will contact at z=1.630000 probe: at 267.996,271.004 bed will contact at z=1.622500 probe: at 267.996,71.995 bed will contact at z=1.440000 probe: at 267.996,71.995 bed will contact at z=1.445000 probe: at 267.996,71.995 bed will contact at z=1.435000 probe: at 67.000,71.995 bed will contact at z=1.480000 probe: at 67.000,71.995 bed will contact at z=1.465000 probe: at 67.000,71.995 bed will contact at z=1.467500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=1.64000 front right screw : x=285.0, y=241.0, z=1.62250 : adjust CCW 00:02 rear right screw : x=285.0, y=42.0, z=1.44000 : adjust CCW 00:24 rear left screw : x=84.0, y=42.0, z=1.46750 : adjust CCW 00:21

History — 3 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-06-18T09:02:01.319773 PASS 200040000D51353234323830 2026-06-18T09:10:22
2026-06-18T07:32:38.242972 PASS 200040000D51353234323830 2026-08-15T03:53:37
2026-06-18T07:04:34.478798 FAIL 200040000D51353234323830 2026-08-15T03:53:36