← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

220040000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 0281605119E6
Start : 2026-08-18T06:12:31.810444 · End : 2026-08-18T06:24:32.512899 · Duration : 720 s
Received (server) : 2026-08-18T06:29:13
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 06:12:31
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=220040000D51353234323830
Home X PASS 06:12:57
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.3747 gap=1.6253 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 06:13:30
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 06:13:36
Part fan PASS 06:13:38
Hotend fan PASS 06:13:40
Hotend heat 220°C PASS 06:13:40
Bed heat 60°C PASS 06:13:40
Cutter (feed+cut) PASS 06:16:11
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.3747 gap=1.6253 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 06:16:22
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 06:18:59
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.5941 gap=1.4059 (2/4) tap 4: pos=-18.1797 gap=1.8203 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.5819 spread=0.5972mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=467.647500 probe at 49.995,339.999 is z=388.630000 Tap drift (diff=79.0175mm) — reset probe at 49.995,339.999 is z=388.635000 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 49.995,339.999 is z=388.652500 Tap drift (diff=0.0175mm) — reset probe at 49.995,339.999 is z=388.637500 Tap drift (diff=0.0150mm) — reset probe at 49.995,339.999 is z=390.205000 Tap drift (diff=1.5675mm) — reset Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) Tap OK (diff=0.0000mm, stable 2/5) probe at 49.995,339.999 is z=389.202500 Tap drift (diff=0.5650mm) — reset probe at 49.995,339.999 is z=388.640000 Tap drift (diff=0.5625mm) — reset Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 5/5)
Z tap repeatability PASS 06:23:54 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0000, 485.9025, 485.9000, 485.8975, 485.8900, 485.9000, 485.9025, 485.9050, 485.9025, 485.9000, 485.9000, 485.9025, 485.9000, 485.9025, 485.9025
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=0.987500 probe at 49.998,339.999 is z=0.992500 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.998,339.999 is z=0.997500 Tap OK (diff=0.0050mm, stable 3/5) probe at 49.998,339.999 is z=1.000000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=1.0000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=485.897500 probe at 49.998,339.999 is z=485.902500 Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) VALIDATED: trigger_z=485.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.895000 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.998,339.999 is z=485.900000 VALIDATED: trigger_z=485.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.890000 Tap OK (diff=0.0025mm, stable 3/5) VALIDATED: trigger_z=485.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=488.857500 Tap drift (diff=2.9675mm) — reset Tap drift (diff=2.9625mm) — reset probe at 49.998,339.999 is z=485.892500 probe at 49.998,339.999 is z=486.605000 Tap drift (diff=0.7100mm) — reset probe at 49.998,339.999 is z=488.090000 Tap drift (diff=2.1950mm) — reset Tap drift (diff=2.1975mm) — reset probe at 49.998,339.999 is z=486.842500 Tap drift (diff=0.9525mm) — reset Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) probe at 49.998,339.999 is z=485.887500 Tap drift (diff=0.9550mm) — reset Tap OK (diff=0.0000mm, stable 2/5)
Screws tilt PASS 06:24:32
probe: at 54.997,328.001 bed will contact at z=1.957500 probe: at 54.997,328.001 bed will contact at z=1.947500 probe: at 380.001,328.001 bed will contact at z=2.065000 probe: at 380.001,328.001 bed will contact at z=2.052500 probe: at 380.001,101.996 bed will contact at z=2.062500 probe: at 380.001,101.996 bed will contact at z=2.050000 probe: at 380.001,101.996 bed will contact at z=2.070000 probe: at 54.997,101.996 bed will contact at z=1.970000 probe: at 54.997,101.996 bed will contact at z=1.967500 probe: at 217.505,214.498 bed will contact at z=2.052500 probe: at 217.505,214.498 bed will contact at z=2.042500 probe: at 217.505,214.498 bed will contact at z=2.020000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.95750 front right screw : x=397.0, y=298.0, z=2.06500 : adjust CW 00:13 rear right screw : x=397.0, y=72.0, z=2.06250 : adjust CW 00:13 rear left screw : x=72.0, y=72.0, z=1.97000 : adjust CW 00:02 middle : x=234.5, y=184.5, z=2.04250 : adjust CW 00:10

History — 3 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-08-18T06:12:31.810444 PASS 220040000D51353234323830 2026-08-18T06:29:13
2026-08-18T06:11:03.268676 PARTIAL 220040000D51353234323830 2026-08-18T06:11:59
2026-08-18T05:56:12.008297 PARTIAL 220040000D51353234323830 2026-08-18T05:57:04