| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 06:12:31 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=220040000D51353234323830
|
| Home X | PASS | 06:12:57 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.3747 gap=1.6253 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 06:13:30 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.5941 gap=1.4059 (chauffe, ignore)
tap 2: pos=-18.7769 gap=1.2231 (1/4)
tap 3: pos=-18.7769 gap=1.2231 (2/4)
tap 4: pos=-18.7769 gap=1.2231 (3/4)
tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
|
| Motherboard fan | PASS | 06:13:36 | |
| Part fan | PASS | 06:13:38 | |
| Hotend fan | PASS | 06:13:40 | |
| Hotend heat 220°C | PASS | 06:13:40 | |
| Bed heat 60°C | PASS | 06:13:40 | |
| Cutter (feed+cut) | PASS | 06:16:11 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.3747 gap=1.6253 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-18.7769 gap=1.2231 (1/4)
tap 3: pos=-18.7769 gap=1.2231 (2/4)
tap 4: pos=-18.7769 gap=1.2231 (3/4)
tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 06:16:22 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 06:18:59 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.3869 gap=1.6131 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-18.7769 gap=1.2231 (1/4)
tap 3: pos=-18.5941 gap=1.4059 (2/4)
tap 4: pos=-18.1797 gap=1.8203 (3/4)
tap 5: pos=-18.7769 gap=1.2231 fenetre=0.5972/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.5819 spread=0.5972mm (tol=0.0500). Zero pose en butee=-18.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,339.999 is z=467.647500
probe at 49.995,339.999 is z=388.630000
Tap drift (diff=79.0175mm) — reset
probe at 49.995,339.999 is z=388.635000
Tap OK (diff=0.0050mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
probe at 49.995,339.999 is z=388.652500
Tap drift (diff=0.0175mm) — reset
probe at 49.995,339.999 is z=388.637500
Tap drift (diff=0.0150mm) — reset
probe at 49.995,339.999 is z=390.205000
Tap drift (diff=1.5675mm) — reset
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
Tap OK (diff=0.0000mm, stable 2/5)
probe at 49.995,339.999 is z=389.202500
Tap drift (diff=0.5650mm) — reset
probe at 49.995,339.999 is z=388.640000
Tap drift (diff=0.5625mm) — reset
Tap OK (diff=0.0025mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 5/5)
|
| Z tap repeatability | PASS | 06:23:54 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0000, 485.9025, 485.9000, 485.8975, 485.8900, 485.9000, 485.9025, 485.9050, 485.9025, 485.9000, 485.9000, 485.9025, 485.9000, 485.9025, 485.9025
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,339.999 is z=0.987500
probe at 49.998,339.999 is z=0.992500
Tap OK (diff=0.0050mm, stable 2/5)
probe at 49.998,339.999 is z=0.997500
Tap OK (diff=0.0050mm, stable 3/5)
probe at 49.998,339.999 is z=1.000000
Tap OK (diff=0.0025mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=1.0000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
probe at 49.998,339.999 is z=485.897500
probe at 49.998,339.999 is z=485.902500
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
VALIDATED: trigger_z=485.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 49.998,339.999 is z=485.895000
Tap OK (diff=0.0025mm, stable 2/5)
probe at 49.998,339.999 is z=485.900000
VALIDATED: trigger_z=485.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 49.998,339.999 is z=485.890000
Tap OK (diff=0.0025mm, stable 3/5)
VALIDATED: trigger_z=485.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 49.998,339.999 is z=488.857500
Tap drift (diff=2.9675mm) — reset
Tap drift (diff=2.9625mm) — reset
probe at 49.998,339.999 is z=485.892500
probe at 49.998,339.999 is z=486.605000
Tap drift (diff=0.7100mm) — reset
probe at 49.998,339.999 is z=488.090000
Tap drift (diff=2.1950mm) — reset
Tap drift (diff=2.1975mm) — reset
probe at 49.998,339.999 is z=486.842500
Tap drift (diff=0.9525mm) — reset
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
probe at 49.998,339.999 is z=485.887500
Tap drift (diff=0.9550mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
|
| Screws tilt | PASS | 06:24:32 |
probe: at 54.997,328.001 bed will contact at z=1.957500
probe: at 54.997,328.001 bed will contact at z=1.947500
probe: at 380.001,328.001 bed will contact at z=2.065000
probe: at 380.001,328.001 bed will contact at z=2.052500
probe: at 380.001,101.996 bed will contact at z=2.062500
probe: at 380.001,101.996 bed will contact at z=2.050000
probe: at 380.001,101.996 bed will contact at z=2.070000
probe: at 54.997,101.996 bed will contact at z=1.970000
probe: at 54.997,101.996 bed will contact at z=1.967500
probe: at 217.505,214.498 bed will contact at z=2.052500
probe: at 217.505,214.498 bed will contact at z=2.042500
probe: at 217.505,214.498 bed will contact at z=2.020000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=298.0, z=1.95750
front right screw : x=397.0, y=298.0, z=2.06500 : adjust CW 00:13
rear right screw : x=397.0, y=72.0, z=2.06250 : adjust CW 00:13
rear left screw : x=72.0, y=72.0, z=1.97000 : adjust CW 00:02
middle : x=234.5, y=184.5, z=2.04250 : adjust CW 00:10
|
| QC date | Result | QC pad (MAC) | Received (server) |
|---|---|---|---|
| 2026-08-18T06:12:31.810444 | PASS | 220040000D51353234323830 | 2026-08-18T06:29:13 |
| 2026-08-18T06:11:03.268676 | PARTIAL | 220040000D51353234323830 | 2026-08-18T06:11:59 |
| 2026-08-18T05:56:12.008297 | PARTIAL | 220040000D51353234323830 | 2026-08-18T05:57:04 |