PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 0281D225B2A9
Start : 2026-07-17T07:38:33.847316 · End : 2026-07-17T07:52:10.908241 · Duration : 817 s
Received (server) : 2026-07-17T08:12:36
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 07:38:33
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=24005A000C51353234323830
Home X PASS 07:38:59
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=357.1797 gap=1.8203 (1/4) tap 3: pos=357.7769 gap=1.2231 (2/4) tap 4: pos=357.5941 gap=1.4059 (3/4) tap 5: pos=357.1797 gap=1.8203 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.4326 spread=0.5972mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 07:39:37
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=-30.0091 gap=1.9909 (1/4) tap 3: pos=-30.7647 gap=1.2353 (2/4) tap 4: pos=-30.0091 gap=1.9909 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.7678/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.3899 spread=0.7678mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 07:40:02
Part fan PASS 07:40:04
Hotend fan PASS 07:40:07
Hotend heat 220°C PASS 07:40:07
Bed heat 60°C PASS 07:40:07
Cutter (feed+cut) PASS 07:43:51
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=357.1797 gap=1.8203 fenetre=0.1828/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.0426 spread=0.1828mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-30.0091 gap=1.9909 (1/4) tap 3: pos=-30.7647 gap=1.2353 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.7678/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.1919 spread=0.7678mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 07:44:06
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 07:46:15
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-30.7647 gap=1.2353 (1/4) tap 3: pos=-30.0091 gap=1.9909 (2/4) tap 4: pos=-30.7647 gap=1.2353 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.7678/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.3838 spread=0.7678mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=312.532500 probe at 65.996,275.995 is z=315.285000 Tap drift (diff=2.7525mm) — reset probe at 65.996,275.995 is z=318.047500 Tap drift (diff=2.7625mm) — reset probe at 65.996,275.995 is z=312.572500 Tap drift (diff=5.4750mm) — reset probe at 65.996,275.995 is z=315.325000 probe at 65.996,275.995 is z=318.085000 Tap drift (diff=2.7600mm) — reset probe at 65.996,275.995 is z=312.642500 Tap drift (diff=5.4425mm) — reset probe at 65.996,275.995 is z=312.607500 Tap drift (diff=0.0350mm) — reset probe at 65.996,275.995 is z=315.362500 Tap drift (diff=2.7550mm) — reset probe at 65.996,275.995 is z=318.140000 Tap drift (diff=2.7775mm) — reset probe at 65.996,275.995 is z=320.762500 Tap drift (diff=2.6225mm) — reset Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
Z tap repeatability PASS 07:51:28 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9000, 385.9075, 385.9050, 385.9025, 385.9025, 385.9025, 385.9025, 385.9025, 385.9000, 385.9075, 385.9000, 385.9050, 385.8950, 385.9175, 385.8925
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=0.800000 probe at 65.999,275.995 is z=0.900000 Tap drift (diff=0.1000mm) — reset probe at 65.999,275.995 is z=0.897500 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=385.877500 probe at 65.999,275.995 is z=385.900000 Tap drift (diff=0.0225mm) — reset probe at 65.999,275.995 is z=385.902500 Tap OK (diff=0.0000mm, stable 3/5) probe at 65.999,275.995 is z=385.905000 Tap OK (diff=0.0025mm, stable 4/5) probe at 65.999,275.995 is z=385.907500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=385.9075 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.890000 Tap drift (diff=0.0125mm) — reset Tap OK (diff=0.0000mm, stable 2/5) VALIDATED: trigger_z=385.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.882500 Tap drift (diff=0.0200mm) — reset VALIDATED: trigger_z=385.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.885000 Tap drift (diff=0.0175mm) — reset probe at 65.999,275.995 is z=388.642500 Tap drift (diff=2.7600mm) — reset probe at 65.999,275.995 is z=391.402500 Tap drift (diff=5.5125mm) — reset Tap drift (diff=0.0100mm) — reset probe at 65.999,275.995 is z=385.880000 probe at 65.999,275.995 is z=385.887500 probe at 65.999,275.995 is z=385.897500
Screws tilt PASS 07:52:10
probe: at 67.000,271.004 bed will contact at z=1.017500 probe: at 67.000,271.004 bed will contact at z=1.070000 Probe samples exceed tolerance. Retrying... probe: at 67.000,271.004 bed will contact at z=1.015000 probe: at 67.000,271.004 bed will contact at z=1.130000 probe: at 67.000,271.004 bed will contact at z=1.167500 probe: at 67.000,271.004 bed will contact at z=1.055000 probe: at 67.000,271.004 bed will contact at z=1.052500 probe: at 67.000,271.004 bed will contact at z=1.075000 probe: at 67.000,271.004 bed will contact at z=1.107500 probe: at 67.000,271.004 bed will contact at z=1.090000 probe: at 67.000,271.004 bed will contact at z=1.072500 probe: at 267.996,271.004 bed will contact at z=0.920000 probe: at 267.996,271.004 bed will contact at z=0.925000 probe: at 267.996,71.995 bed will contact at z=1.012500 probe: at 267.996,71.995 bed will contact at z=1.027500 probe: at 67.000,71.995 bed will contact at z=0.945000 probe: at 67.000,71.995 bed will contact at z=0.992500 probe: at 67.000,71.995 bed will contact at z=0.947500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=1.07250 front right screw : x=285.0, y=241.0, z=0.92500 : adjust CCW 00:18 rear right screw : x=285.0, y=42.0, z=1.02750 : adjust CCW 00:05 rear left screw : x=84.0, y=42.0, z=0.94750 : adjust CCW 00:15