SmartPi 1
SmartPi 2

270051000C51353234323830

PASS Grade A Grade B
Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 02813C788EB7
Start : 2026-06-27T08:49:58.284391 · End : 2026-06-27T09:03:19.940402 · Duration : 801 s
Received (server) : 2026-06-29T00:38:50
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 08:49:58
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=270051000C51353234323830
Home X PASS 08:50:19
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 08:50:49
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9847 gap=2.0153 (3/4) tap 5: pos=-30.0091 gap=1.9909 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 08:51:01
Part fan PASS 08:51:04
Hotend fan PASS 08:51:07
Hotend heat 220°C PASS 08:51:10
Bed heat 60°C PASS 08:51:30
Cutter (feed+cut) PASS 08:52:53
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-30.1797 gap=1.8203 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.8141 gap=2.1859 (3/4) tap 5: pos=-30.1797 gap=1.8203 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.0426 spread=0.3656mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 08:53:03
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 08:56:05
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=256.1919 gap=1.8081 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=256.0456 spread=0.1950mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3747 gap=1.6253 (chauffe, ignore) tap 2: pos=-29.8141 gap=2.1859 (1/4) tap 3: pos=-30.1797 gap=1.8203 (2/4) tap 4: pos=-29.8141 gap=2.1859 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-29.9512 spread=0.3656mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=156.182500 probe at 31.003,211.998 is z=156.210000 Tap drift (diff=0.0275mm) — reset probe at 31.003,211.998 is z=156.185000 Tap drift (diff=0.0250mm) — reset Tap OK (diff=0.0025mm, stable 2/5) probe at 31.003,211.998 is z=156.207500 Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=156.2100 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 09:02:25 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9075, 255.9000, 255.9000, 255.9000, 256.0150, 255.9050, 255.9375, 255.9075, 255.8975, 255.8975, 255.9075, 255.8925, 255.9050, 255.8925, 255.9125
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=0.870000 probe at 30.994,211.998 is z=0.875000 Tap OK (diff=0.0050mm, stable 2/5) probe at 30.994,211.998 is z=0.902500 Tap drift (diff=0.0275mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 30.994,211.998 is z=0.905000 Tap OK (diff=0.0025mm, stable 3/5) probe at 30.994,211.998 is z=0.907500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.9075 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.895000 probe at 30.994,211.998 is z=255.897500 Tap OK (diff=0.0025mm, stable 2/5) probe at 30.994,211.998 is z=255.900000 Tap OK (diff=0.0000mm, stable 4/5) VALIDATED: trigger_z=255.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.902500 probe at 30.994,211.998 is z=255.905000 Tap OK (diff=0.0050mm, stable 5/5) probe at 30.994,211.998 is z=255.862500 Tap drift (diff=0.0375mm) — reset Tap drift (diff=0.0400mm) — reset Tap OK (diff=0.0000mm, stable 3/5) probe at 30.994,211.998 is z=255.990000 Tap drift (diff=0.0850mm) — reset probe at 30.994,211.998 is z=255.935000 Tap drift (diff=0.0550mm) — reset probe at 30.994,211.998 is z=255.992500 Tap drift (diff=0.0575mm) — reset probe at 30.994,211.998 is z=255.937500 probe at 30.994,211.998 is z=255.987500 Tap drift (diff=0.0500mm) — reset probe at 30.994,211.998 is z=255.887500 Tap drift (diff=0.1000mm) — reset
Screws tilt PASS 09:03:19
probe: at 32.495,205.497 bed will contact at z=2.237500 probe: at 32.495,205.497 bed will contact at z=2.407500 Probe samples exceed tolerance. Retrying... probe: at 32.495,205.497 bed will contact at z=2.402500 probe: at 32.495,205.497 bed will contact at z=2.397500 probe: at 32.495,205.497 bed will contact at z=2.392500 probe: at 206.996,205.497 bed will contact at z=3.615000 probe: at 206.996,205.497 bed will contact at z=3.785000 probe: at 206.996,205.497 bed will contact at z=3.795000 probe: at 206.996,205.497 bed will contact at z=3.642500 probe: at 206.996,205.497 bed will contact at z=3.800000 probe: at 206.996,205.497 bed will contact at z=3.622500 probe: at 206.996,205.497 bed will contact at z=3.792500 probe: at 206.996,205.497 bed will contact at z=3.627500 probe: at 206.996,205.497 bed will contact at z=3.807500 probe: at 206.996,205.497 bed will contact at z=3.617500 probe: at 206.996,205.497 bed will contact at z=3.810000 probe: at 206.996,205.497 bed will contact at z=3.637500 probe: at 206.996,205.497 bed will contact at z=3.787500 probe: at 206.996,205.497 bed will contact at z=3.635000 probe: at 206.996,205.497 bed will contact at z=3.797500 probe: at 206.996,31.995 bed will contact at z=3.902500 probe: at 206.996,31.995 bed will contact at z=4.060000 probe: at 206.996,31.995 bed will contact at z=4.070000 probe: at 206.996,31.995 bed will contact at z=4.055000 probe: at 32.495,31.995 bed will contact at z=2.702500 probe: at 32.495,31.995 bed will contact at z=2.862500 probe: at 32.495,31.995 bed will contact at z=2.830000 probe: at 32.495,31.995 bed will contact at z=2.840000 probe: at 32.495,31.995 bed will contact at z=2.845000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=2.39750 front right screw : x=224.0, y=175.5, z=3.79750 : adjust CW 02:48 rear right screw : x=224.0, y=2.0, z=4.06000 : adjust CW 03:19 rear left screw : x=49.5, y=2.0, z=2.84000 : adjust CW 00:53

History — 2 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-06-27T08:49:58.284391 PASS 270051000C51353234323830 2026-06-29T00:38:50
2026-06-27T08:46:07.391092 FAIL 270051000C51353234323830 2026-06-27T08:41:38