← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

2D0053000C51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 110V · 550W · SSR SSR10DA
QC pad (MAC) : 0281AE52CB5F
Start : 2026-08-08T03:11:08.012949 · End : 2026-08-08T03:23:15.442093 · Duration : 727 s
Received (server) : 2026-08-08T04:15:17
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=550 ssr=SSR10DA lot=20260618 uid=2ACAAE

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 03:11:08
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=2D0053000C51353234323830
Home X PASS 03:11:33
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=456.8141 gap=2.1859 (1/4) tap 3: pos=457.1797 gap=1.8203 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 03:12:17
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1 rejete: aucun contact sur 7.0mm (No trigger on probe after full movement) tap 2 rejete: aucun contact sur 7.0mm (No trigger on probe after full movement) YUMI_SENSORLESS_HOME Y: home de base suspect (pas de contact) -> re-home de recuperation 1/2 tap 3: pos=-18.7769 gap=1.2231 (chauffe, ignore) tap 4: pos=-18.5819 gap=1.4181 (1/4) tap 5: pos=-17.9969 gap=2.0031 (2/4) tap 6: pos=-18.1797 gap=1.8203 (3/4) tap 7: pos=-18.7769 gap=1.2231 fenetre=0.7800/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (2 rejetes) -> moyenne=-18.3838 spread=0.7800mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 03:12:23
Part fan PASS 03:12:25
Hotend fan PASS 03:12:28
Hotend heat 220°C PASS 03:12:33
Bed heat 60°C PASS 03:13:24
Cutter (feed+cut) PASS 03:14:52
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 03:15:07
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 03:18:09
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=457.1797 gap=1.8203 (1/4) tap 3: pos=456.8141 gap=2.1859 (2/4) tap 4: pos=457.1797 gap=1.8203 (3/4) tap 5: pos=456.8141 gap=2.1859 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=406.150000 probe at 49.995,339.999 is z=406.185000 Tap drift (diff=0.0350mm) — reset probe at 49.995,339.999 is z=406.187500 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.995,339.999 is z=406.190000 Tap OK (diff=0.0025mm, stable 3/5) probe at 49.995,339.999 is z=406.192500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=406.1925 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 03:22:39 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1200, 486.1050, 486.1000, 486.1050, 486.1025, 486.1025, 486.1000, 486.1025, 486.1000, 486.1025, 486.1025, 486.1000, 486.1000, 486.1025, 486.1050
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=1.097500 probe at 49.998,339.999 is z=1.110000 Tap drift (diff=0.0125mm) — reset probe at 49.998,339.999 is z=1.115000 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.998,339.999 is z=1.117500 Tap OK (diff=0.0025mm, stable 3/5) probe at 49.998,339.999 is z=1.120000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=1.1200 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=486.095000 probe at 49.998,339.999 is z=486.100000 probe at 49.998,339.999 is z=486.102500 Tap OK (diff=0.0000mm, stable 4/5) probe at 49.998,339.999 is z=486.105000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,339.999 is z=486.107500 Tap OK (diff=0.0050mm, stable 4/5) probe at 49.998,339.999 is z=486.097500 VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0050mm, stable 3/5) Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0075mm, stable 5/5)
Screws tilt PASS 03:23:15
probe: at 54.997,328.001 bed will contact at z=3.117500 probe: at 54.997,328.001 bed will contact at z=3.120000 probe: at 54.997,328.001 bed will contact at z=3.127500 probe: at 380.001,328.001 bed will contact at z=3.092500 probe: at 380.001,328.001 bed will contact at z=3.080000 probe: at 380.001,328.001 bed will contact at z=3.082500 probe: at 380.001,101.996 bed will contact at z=3.210000 probe: at 380.001,101.996 bed will contact at z=3.175000 probe: at 380.001,101.996 bed will contact at z=3.162500 probe: at 54.997,101.996 bed will contact at z=3.175000 probe: at 54.997,101.996 bed will contact at z=3.182500 probe: at 217.505,214.498 bed will contact at z=3.125000 probe: at 217.505,214.498 bed will contact at z=3.132500 probe: at 217.505,214.498 bed will contact at z=3.142500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=3.12000 front right screw : x=397.0, y=298.0, z=3.08250 : adjust CCW 00:04 rear right screw : x=397.0, y=72.0, z=3.17500 : adjust CW 00:07 rear left screw : x=72.0, y=72.0, z=3.17500 : adjust CW 00:07 middle : x=234.5, y=184.5, z=3.13250 : adjust CW 00:02