SmartPi 1
SmartPi 2

2E0043000D51353234323830

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 0281EEB2BA2E
Start : 2026-07-14T08:30:44.476818 · End : 2026-07-14T08:42:17.399992 · Duration : 692 s
Received (server) : 2026-07-17T06:37:47
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 08:30:44
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=2E0043000D51353234323830
Home X PASS 08:31:09
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 08:31:44
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7647 gap=1.2353 (2/4) tap 4: pos=-30.7891 gap=1.2109 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-30.7769 spread=0.0244mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 08:31:50
Part fan PASS 08:31:54
Hotend fan PASS 08:31:58
Hotend heat 220°C PASS 08:32:05
Bed heat 60°C PASS 08:32:10
Cutter (feed+cut) PASS 08:33:35
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7647 gap=1.2353 (2/4) tap 4: pos=-30.7891 gap=1.2109 (3/4) tap 5: pos=-30.5819 gap=1.4181 fenetre=0.2072/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.7281 spread=0.2072mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 08:33:50
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 08:36:50
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4234 gap=1.5766 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-30.7891 gap=1.2109 (1/4) tap 3: pos=-30.7647 gap=1.2353 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.5941 gap=1.4059 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.7312 spread=0.1950mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=364.827500 probe at 65.996,275.995 is z=297.665000 Tap drift (diff=67.1625mm) — reset probe at 65.996,275.995 is z=300.200000 Tap drift (diff=2.5350mm) — reset probe at 65.996,275.995 is z=297.682500 Tap drift (diff=2.5175mm) — reset probe at 65.996,275.995 is z=297.692500 Tap drift (diff=0.0100mm) — reset probe at 65.996,275.995 is z=297.702500 probe at 65.996,275.995 is z=297.705000 Tap OK (diff=0.0025mm, stable 2/5) probe at 65.996,275.995 is z=297.710000 Tap OK (diff=0.0050mm, stable 3/5) probe at 65.996,275.995 is z=297.712500 Tap OK (diff=0.0025mm, stable 4/5) probe at 65.996,275.995 is z=297.717500 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=297.7175 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 08:41:49 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9025, 385.9750, 385.9350, 385.9450, 385.9075, 385.9275, 385.9100, 385.9300, 385.9050, 385.9250, 385.9100, 385.9025, 385.9050, 385.9250, 385.9050
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=285.627500 probe at 65.999,275.995 is z=253.655000 Tap drift (diff=31.9725mm) — reset probe at 65.999,275.995 is z=256.267500 Tap drift (diff=2.6125mm) — reset probe at 65.999,275.995 is z=157.170000 Tap drift (diff=99.0975mm) — reset probe at 65.999,275.995 is z=0.780000 Tap drift (diff=156.3900mm) — reset probe at 65.999,275.995 is z=0.810000 Tap drift (diff=0.0300mm) — reset probe at 65.999,275.995 is z=0.817500 Tap OK (diff=0.0075mm, stable 2/5) probe at 65.999,275.995 is z=0.822500 Tap OK (diff=0.0050mm, stable 3/5) probe at 65.999,275.995 is z=3.465000 Tap drift (diff=2.6425mm) — reset probe at 65.999,275.995 is z=0.845000 Tap drift (diff=2.6200mm) — reset probe at 65.999,275.995 is z=0.852500 probe at 65.999,275.995 is z=0.850000 Tap OK (diff=0.0025mm, stable 3/5) probe at 65.999,275.995 is z=0.860000 Tap drift (diff=0.0100mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 65.999,275.995 is z=0.875000 Tap drift (diff=0.0150mm) — reset probe at 65.999,275.995 is z=0.887500 Tap drift (diff=0.0125mm) — reset probe at 65.999,275.995 is z=0.892500 probe at 65.999,275.995 is z=0.897500 Tap OK (diff=0.0050mm, stable 4/5) probe at 65.999,275.995 is z=0.902500 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=0.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=385.922500
Screws tilt PASS 08:42:17
probe: at 67.000,271.004 bed will contact at z=2.267500 probe: at 67.000,271.004 bed will contact at z=2.260000 probe: at 67.000,271.004 bed will contact at z=2.282500 probe: at 267.996,271.004 bed will contact at z=3.420000 probe: at 267.996,271.004 bed will contact at z=3.422500 probe: at 267.996,271.004 bed will contact at z=3.432500 probe: at 267.996,71.995 bed will contact at z=3.337500 probe: at 267.996,71.995 bed will contact at z=3.332500 probe: at 267.996,71.995 bed will contact at z=3.350000 probe: at 67.000,71.995 bed will contact at z=2.322500 probe: at 67.000,71.995 bed will contact at z=2.347500 probe: at 67.000,71.995 bed will contact at z=2.312500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=2.26750 front right screw : x=285.0, y=241.0, z=3.42250 : adjust CW 02:19 rear right screw : x=285.0, y=42.0, z=3.33750 : adjust CW 02:08 rear left screw : x=84.0, y=42.0, z=2.32250 : adjust CW 00:07