← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

300045000D51353234323830

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 0281EEB2BA2E
Start : 2026-07-14T04:39:44.591352 · End : 2026-07-14T04:51:20.941423 · Duration : 696 s
Received (server) : 2026-07-17T06:37:50
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 04:39:44
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=300045000D51353234323830
Home X PASS 04:40:11
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 04:40:49
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 04:40:52
Part fan PASS 04:40:54
Hotend fan PASS 04:40:57
Hotend heat 220°C PASS 04:40:57
Bed heat 60°C PASS 04:40:57
Cutter (feed+cut) PASS 04:42:32
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 04:42:47
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 04:45:34
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7769 gap=1.2231 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.7800/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.5819 spread=0.7800mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=315.807500 probe at 65.996,275.995 is z=315.957500 Tap drift (diff=0.1500mm) — reset probe at 65.996,275.995 is z=315.960000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 65.996,275.995 is z=315.962500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=315.9625 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 04:50:43 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8650, 385.9200, 385.9050, 385.9025, 385.9025, 385.9025, 385.9000, 385.9025, 385.9050, 385.9000, 385.9100, 385.9025, 385.9100, 385.9000, 385.9000
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=395.655000 probe at 65.999,275.995 is z=0.727500 Tap drift (diff=394.9275mm) — reset probe at 65.999,275.995 is z=0.860000 Tap drift (diff=0.1325mm) — reset probe at 65.999,275.995 is z=0.865000 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.8650 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=385.895000 probe at 65.999,275.995 is z=385.917500 Tap drift (diff=0.0225mm) — reset probe at 65.999,275.995 is z=385.915000 Tap OK (diff=0.0025mm, stable 2/5) probe at 65.999,275.995 is z=385.920000 Tap OK (diff=0.0050mm, stable 3/5) VALIDATED: trigger_z=385.9200 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.877500 probe at 65.999,275.995 is z=385.902500 Tap drift (diff=0.0250mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 65.999,275.995 is z=385.905000 Tap OK (diff=0.0025mm, stable 4/5) VALIDATED: trigger_z=385.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.875000 probe at 65.999,275.995 is z=385.900000 VALIDATED: trigger_z=385.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.892500 Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0025mm, stable 5/5) probe at 65.999,275.995 is z=388.495000 Tap drift (diff=2.5950mm) — reset Tap drift (diff=2.6000mm) — reset
Screws tilt PASS 04:51:20
probe: at 67.000,271.004 bed will contact at z=1.655000 probe: at 67.000,271.004 bed will contact at z=1.632500 probe: at 67.000,271.004 bed will contact at z=1.665000 probe: at 267.996,271.004 bed will contact at z=1.987500 probe: at 267.996,271.004 bed will contact at z=2.040000 Probe samples exceed tolerance. Retrying... probe: at 267.996,271.004 bed will contact at z=2.010000 probe: at 267.996,271.004 bed will contact at z=1.970000 probe: at 267.996,271.004 bed will contact at z=2.017500 probe: at 267.996,71.995 bed will contact at z=1.997500 probe: at 267.996,71.995 bed will contact at z=1.945000 probe: at 267.996,71.995 bed will contact at z=1.955000 probe: at 267.996,71.995 bed will contact at z=1.900000 probe: at 267.996,71.995 bed will contact at z=1.962500 probe: at 67.000,71.995 bed will contact at z=1.560000 probe: at 67.000,71.995 bed will contact at z=1.582500 probe: at 67.000,71.995 bed will contact at z=1.570000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=1.65500 front right screw : x=285.0, y=241.0, z=2.01000 : adjust CW 00:43 rear right screw : x=285.0, y=42.0, z=1.94500 : adjust CW 00:35 rear left screw : x=84.0, y=42.0, z=1.57000 : adjust CCW 00:10

History — 2 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-07-14T04:39:44.591352 PASS 300045000D51353234323830 2026-07-17T06:37:50
2026-07-14T04:29:42.811253 FAIL 300045000D51353234323830 2026-07-14T04:39:03