| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 07:43:58 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=30005E000C51353234323830
|
| Home X | PASS | 07:44:24 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.5819 gap=1.4181 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9847 gap=2.0153 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0122/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9938 spread=0.0122mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 07:45:01 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
|
| Motherboard fan | PASS | 07:45:30 | |
| Part fan | PASS | 07:45:33 | |
| Hotend fan | PASS | 07:45:35 | |
| Hotend heat 220°C | PASS | 07:45:35 | |
| Bed heat 60°C | PASS | 07:45:41 | |
| Cutter (feed+cut) | PASS | 07:47:47 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=456.9847 gap=2.0153 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=457.0091 gap=1.9909 (3/4)
tap 5: pos=456.8019 gap=2.1981 fenetre=0.2072/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9481 spread=0.2072mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 07:48:01 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 07:50:48 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore)
tap 2: pos=457.1797 gap=1.8203 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.1828/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.0426 spread=0.1828mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,339.999 is z=410.315000
probe at 49.995,339.999 is z=410.280000
Tap drift (diff=0.0350mm) — reset
probe at 49.995,339.999 is z=410.320000
Tap drift (diff=0.0400mm) — reset
probe at 49.995,339.999 is z=410.317500
Tap OK (diff=0.0025mm, stable 2/5)
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
probe at 49.995,339.999 is z=410.325000
Tap drift (diff=0.0100mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
Tap OK (diff=0.0100mm, stable 3/5)
Tap OK (diff=0.0025mm, stable 4/5)
probe at 49.995,339.999 is z=410.312500
Tap OK (diff=0.0050mm, stable 5/5)
VALIDATED: trigger_z=410.3125 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 07:56:30 |
OK: 3 taps convergents spread=0.0050mm (tol=0.0500) sur 15 taps | taps=1.1150, 486.1125, 486.0925, 486.1150, 486.0850, 486.2275, 485.9950, 486.1075, 486.1025, 486.0850, 486.2175, 485.9950, 486.0975, 486.0925, 486.0975
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,339.999 is z=192.472500
probe at 49.998,339.999 is z=1.160000
Tap drift (diff=191.3125mm) — reset
probe at 49.998,339.999 is z=1.265000
Tap drift (diff=0.1050mm) — reset
probe at 49.998,339.999 is z=1.235000
Tap drift (diff=0.0300mm) — reset
probe at 49.998,339.999 is z=1.237500
Tap OK (diff=0.0025mm, stable 2/5)
probe at 49.998,339.999 is z=2.875000
Tap drift (diff=1.6375mm) — reset
probe at 49.998,339.999 is z=1.077500
Tap drift (diff=1.7975mm) — reset
probe at 49.998,339.999 is z=1.115000
Tap drift (diff=0.0375mm) — reset
probe at 49.998,339.999 is z=1.117500
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=1.1150 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
probe at 49.998,339.999 is z=486.100000
probe at 49.998,339.999 is z=486.102500
probe at 49.998,339.999 is z=486.105000
Tap OK (diff=0.0025mm, stable 3/5)
probe at 49.998,339.999 is z=486.112500
Tap OK (diff=0.0075mm, stable 5/5)
VALIDATED: trigger_z=486.1125 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,339.999 is z=486.097500
Tap OK (diff=0.0050mm, stable 3/5)
probe at 49.998,339.999 is z=486.095000
Tap OK (diff=0.0100mm, stable 4/5)
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
probe at 49.998,339.999 is z=486.092500
VALIDATED: trigger_z=486.0925 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,339.999 is z=486.110000
probe at 49.998,339.999 is z=486.115000
|
| Screws tilt | PASS | 07:57:18 |
probe: at 54.997,328.001 bed will contact at z=1.800000
probe: at 54.997,328.001 bed will contact at z=1.752500
probe: at 54.997,328.001 bed will contact at z=1.665000
Probe samples exceed tolerance. Retrying...
probe: at 54.997,328.001 bed will contact at z=1.700000
probe: at 54.997,328.001 bed will contact at z=1.757500
probe: at 54.997,328.001 bed will contact at z=1.792500
probe: at 54.997,328.001 bed will contact at z=1.742500
probe: at 54.997,328.001 bed will contact at z=1.812500
probe: at 54.997,328.001 bed will contact at z=1.847500
probe: at 54.997,328.001 bed will contact at z=1.817500
probe: at 54.997,328.001 bed will contact at z=1.802500
probe: at 380.001,328.001 bed will contact at z=1.652500
probe: at 380.001,328.001 bed will contact at z=1.655000
probe: at 380.001,328.001 bed will contact at z=1.645000
probe: at 380.001,101.996 bed will contact at z=1.687500
probe: at 380.001,101.996 bed will contact at z=1.697500
probe: at 380.001,101.996 bed will contact at z=1.690000
probe: at 54.997,101.996 bed will contact at z=1.690000
probe: at 54.997,101.996 bed will contact at z=1.735000
probe: at 54.997,101.996 bed will contact at z=1.707500
probe: at 217.505,214.498 bed will contact at z=1.785000
probe: at 217.505,214.498 bed will contact at z=1.780000
probe: at 217.505,214.498 bed will contact at z=1.802500
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=298.0, z=1.81750
front right screw : x=397.0, y=298.0, z=1.65250 : adjust CCW 00:20
rear right screw : x=397.0, y=72.0, z=1.69000 : adjust CCW 00:15
rear left screw : x=72.0, y=72.0, z=1.70750 : adjust CCW 00:13
middle : x=234.5, y=184.5, z=1.78500 : adjust CCW 00:04
|
Moves this report to the trash — you can restore it from /trash.