← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

31005C000C51353234323830

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 0281EB778EE3
Start : 2026-07-22T06:54:58.431840 · End : 2026-07-22T07:05:50.789114 · Duration : 652 s
Received (server) : 2026-07-22T07:07:46
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 06:54:58
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=31005C000C51353234323830
Home X PASS 06:55:25
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.8019 gap=2.1981 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=356.9481 spread=0.1950mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 06:56:03
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9847 gap=2.0153 (1/4) tap 3: pos=-30.0091 gap=1.9909 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 06:56:08
Part fan PASS 06:56:10
Hotend fan PASS 06:56:13
Hotend heat 220°C PASS 06:56:13
Bed heat 60°C PASS 06:56:15
Cutter (feed+cut) PASS 06:57:39
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.2163 gap=1.7837 (chauffe, ignore) tap 2: pos=357.1919 gap=1.8081 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.0456 spread=0.1950mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 06:57:53
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 07:00:42
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=357.1919 gap=1.8081 (1/4) tap 3: pos=356.8019 gap=2.1981 (2/4) tap 4: pos=357.1919 gap=1.8081 (3/4) tap 5: pos=356.8019 gap=2.1981 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9847 gap=2.0153 (2/4) tap 4: pos=-30.0091 gap=1.9909 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=315.140000 probe at 65.996,275.995 is z=315.175000 Tap drift (diff=0.0350mm) — reset probe at 65.996,275.995 is z=315.185000 Tap drift (diff=0.0100mm) — reset probe at 65.996,275.995 is z=315.195000 probe at 65.996,275.995 is z=315.202500 Tap OK (diff=0.0075mm, stable 2/5) probe at 65.996,275.995 is z=315.205000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 65.996,275.995 is z=315.207500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=315.2075 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 07:05:15 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1950, 385.8800, 385.8800, 385.8925, 385.8950, 385.8950, 385.8950, 385.8900, 385.8950, 385.8925, 385.9000, 385.8975, 385.9000, 385.8975, 385.9000
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=1.345000 probe at 65.999,275.995 is z=1.185000 Tap drift (diff=0.1600mm) — reset probe at 65.999,275.995 is z=1.177500 Tap OK (diff=0.0075mm, stable 2/5) probe at 65.999,275.995 is z=1.187500 Tap drift (diff=0.0100mm) — reset probe at 65.999,275.995 is z=1.202500 Tap drift (diff=0.0150mm) — reset probe at 65.999,275.995 is z=1.197500 Tap OK (diff=0.0050mm, stable 2/5) probe at 65.999,275.995 is z=1.205000 Tap OK (diff=0.0075mm, stable 3/5) Tap OK (diff=0.0025mm, stable 4/5) probe at 65.999,275.995 is z=1.195000 Tap OK (diff=0.0075mm, stable 5/5) VALIDATED: trigger_z=1.1950 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=385.860000 probe at 65.999,275.995 is z=385.877500 Tap drift (diff=0.0175mm) — reset probe at 65.999,275.995 is z=385.880000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=385.8800 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.870000 probe at 65.999,275.995 is z=385.875000 Tap OK (diff=0.0025mm, stable 3/5) probe at 65.999,275.995 is z=385.882500 probe at 65.999,275.995 is z=385.892500 probe at 65.999,275.995 is z=385.890000 probe at 65.999,275.995 is z=385.895000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=385.8925 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) VALIDATED: trigger_z=385.8950 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Screws tilt PASS 07:05:50
probe: at 67.000,271.004 bed will contact at z=1.000000 probe: at 67.000,271.004 bed will contact at z=0.972500 probe: at 67.000,271.004 bed will contact at z=0.960000 probe: at 267.996,271.004 bed will contact at z=1.002500 probe: at 267.996,271.004 bed will contact at z=1.012500 probe: at 267.996,271.004 bed will contact at z=1.010000 probe: at 267.996,71.995 bed will contact at z=0.952500 probe: at 267.996,71.995 bed will contact at z=0.955000 probe: at 267.996,71.995 bed will contact at z=0.957500 probe: at 67.000,71.995 bed will contact at z=0.800000 probe: at 67.000,71.995 bed will contact at z=0.830000 probe: at 67.000,71.995 bed will contact at z=0.762500 Probe samples exceed tolerance. Retrying... probe: at 67.000,71.995 bed will contact at z=0.792500 probe: at 67.000,71.995 bed will contact at z=0.822500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=0.97250 front right screw : x=285.0, y=241.0, z=1.01000 : adjust CW 00:05 rear right screw : x=285.0, y=42.0, z=0.95500 : adjust CCW 00:02 rear left screw : x=84.0, y=42.0, z=0.80000 : adjust CCW 00:21