← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

330053000C51353234323830

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 0281D225B2A9
Start : 2026-07-18T00:40:49.636402 · End : 2026-07-18T00:52:50.452544 · Duration : 720 s
Received (server) : 2026-07-18T00:55:30
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 00:40:49
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=330053000C51353234323830
Home X PASS 00:41:16
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 00:41:50
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.6062 gap=1.3938 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7769 gap=1.2231 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-30.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 00:41:55
Part fan PASS 00:41:58
Hotend fan PASS 00:42:00
Hotend heat 220°C PASS 00:42:00
Bed heat 60°C PASS 00:42:38
Cutter (feed+cut) PASS 00:44:19
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=356.9847 gap=2.0153 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7769 gap=1.2231 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-30.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 00:44:34
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 00:47:32
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.0213 gap=1.9787 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7769 gap=1.2231 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-30.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=285.827500 probe at 65.996,275.995 is z=285.870000 Tap drift (diff=0.0425mm) — reset probe at 65.996,275.995 is z=285.875000 Tap OK (diff=0.0050mm, stable 2/5) probe at 65.996,275.995 is z=285.877500 Tap OK (diff=0.0025mm, stable 3/5) probe at 65.996,275.995 is z=285.880000 Tap OK (diff=0.0025mm, stable 4/5) probe at 65.996,275.995 is z=285.882500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=285.8825 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 00:52:17 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8275, 385.9075, 385.9025, 385.9025, 385.9025, 385.9000, 385.9025, 385.9000, 385.9000, 385.9025, 385.9000, 385.9025, 385.9000, 385.8975, 385.9025
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=395.745000 probe at 65.999,275.995 is z=398.487500 Tap rejete (vibration chassis, z=398.4875 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 65.999,275.995 is z=398.152500 Tap rejete (vibration chassis, z=398.1525 > max-z_hop) -> pas de remontee, on poursuit la descente (2) probe at 65.999,275.995 is z=355.657500 probe at 65.999,275.995 is z=347.780000 Tap drift (diff=7.8775mm) — reset probe at 65.999,275.995 is z=341.107500 Tap drift (diff=6.6725mm) — reset probe at 65.999,275.995 is z=343.860000 Tap drift (diff=2.7525mm) — reset probe at 65.999,275.995 is z=345.057500 Tap drift (diff=1.1975mm) — reset probe at 65.999,275.995 is z=316.347500 Tap drift (diff=28.7100mm) — reset probe at 65.999,275.995 is z=293.657500 Tap drift (diff=22.6900mm) — reset probe at 65.999,275.995 is z=295.225000 Tap drift (diff=1.5675mm) — reset probe at 65.999,275.995 is z=0.780000 Tap drift (diff=294.4450mm) — reset probe at 65.999,275.995 is z=0.820000 Tap drift (diff=0.0400mm) — reset probe at 65.999,275.995 is z=0.822500 Tap OK (diff=0.0025mm, stable 2/5) probe at 65.999,275.995 is z=0.825000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 65.999,275.995 is z=0.827500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=0.8275 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=385.892500 probe at 65.999,275.995 is z=385.902500 Tap drift (diff=0.0100mm) — reset Tap OK (diff=0.0000mm, stable 2/5)
Screws tilt PASS 00:52:50
probe: at 67.000,271.004 bed will contact at z=2.282500 probe: at 67.000,271.004 bed will contact at z=2.295000 probe: at 67.000,271.004 bed will contact at z=2.300000 probe: at 267.996,271.004 bed will contact at z=2.162500 probe: at 267.996,271.004 bed will contact at z=2.175000 probe: at 267.996,271.004 bed will contact at z=2.190000 probe: at 267.996,71.995 bed will contact at z=2.280000 probe: at 267.996,71.995 bed will contact at z=2.235000 probe: at 267.996,71.995 bed will contact at z=2.287500 Probe samples exceed tolerance. Retrying... probe: at 267.996,71.995 bed will contact at z=2.282500 probe: at 267.996,71.995 bed will contact at z=2.297500 probe: at 267.996,71.995 bed will contact at z=2.267500 probe: at 67.000,71.995 bed will contact at z=2.287500 probe: at 67.000,71.995 bed will contact at z=2.300000 probe: at 67.000,71.995 bed will contact at z=2.302500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=2.29500 front right screw : x=285.0, y=241.0, z=2.17500 : adjust CCW 00:14 rear right screw : x=285.0, y=42.0, z=2.28250 : adjust CCW 00:01 rear left screw : x=84.0, y=42.0, z=2.30000 : adjust CW 00:01

History — 2 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-07-18T00:40:49.636402 PASS 330053000C51353234323830 2026-07-18T00:55:30
2026-07-17T08:43:51.691689 FAIL 330053000C51353234323830 2026-07-17T08:54:59