← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

340045000D51353234323830

PASS Grade A Grade B
Model : C235 · Batch : 20260618
Heated bed : 110V · 300W · SSR SSR10DA
QC pad (MAC) : 02817A147AB3
Start : 2026-07-10T03:20:32.111279 · End : 2026-07-10T03:31:14.422986 · Duration : 642 s
Received (server) : 2026-07-10T04:12:54
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=300 ssr=SSR10DA lot=20260618 uid=BBA413

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 03:20:32
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=300;ssr=SSR10DA;lot=20260618;uid=BBA413 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=340045000D51353234323830
Home X PASS 03:20:54
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 03:21:23
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.9719 gap=1.0281 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 03:21:38
Part fan PASS 03:21:45
Hotend fan PASS 03:21:47
Hotend heat 220°C PASS 03:21:47
Bed heat 60°C PASS 03:21:50
Cutter (feed+cut) PASS 03:23:24
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 03:23:39
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 03:26:23
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9847 gap=2.0153 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9938 spread=0.0122mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=113.467500 probe at 31.003,211.998 is z=113.470000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=113.4700 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 03:30:48 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9975, 255.9000, 255.8875, 255.9000, 255.8975, 255.9075, 255.9025, 255.9025, 255.9025, 255.9000, 255.9025, 255.9000, 255.9025, 255.9000, 255.8975
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=203.850000 probe at 30.994,211.998 is z=199.090000 Tap drift (diff=4.7600mm) — reset probe at 30.994,211.998 is z=182.805000 Tap drift (diff=16.2850mm) — reset probe at 30.994,211.998 is z=178.502500 Tap drift (diff=4.3025mm) — reset probe at 30.994,211.998 is z=179.100000 Tap drift (diff=0.5975mm) — reset probe at 30.994,211.998 is z=117.290000 Tap drift (diff=61.8100mm) — reset probe at 30.994,211.998 is z=49.222500 Tap drift (diff=68.0675mm) — reset probe at 30.994,211.998 is z=26.497500 Tap drift (diff=22.7250mm) — reset probe at 30.994,211.998 is z=23.732500 Tap drift (diff=2.7650mm) — reset probe at 30.994,211.998 is z=25.420000 Tap drift (diff=1.6875mm) — reset probe at 30.994,211.998 is z=21.822500 Tap drift (diff=3.5975mm) — reset probe at 30.994,211.998 is z=19.000000 Tap drift (diff=2.8225mm) — reset probe at 30.994,211.998 is z=0.987500 Tap drift (diff=18.0125mm) — reset probe at 30.994,211.998 is z=0.990000 Tap OK (diff=0.0025mm, stable 2/5) probe at 30.994,211.998 is z=0.992500 Tap OK (diff=0.0025mm, stable 3/5) probe at 30.994,211.998 is z=3.737500 Tap drift (diff=2.7450mm) — reset probe at 30.994,211.998 is z=1.002500 Tap drift (diff=2.7350mm) — reset Tap OK (diff=0.0100mm, stable 2/5) probe at 30.994,211.998 is z=0.995000 probe at 30.994,211.998 is z=1.005000 Tap drift (diff=0.0100mm) — reset Tap OK (diff=0.0000mm, stable 2/5)
Screws tilt PASS 03:31:14
probe: at 32.495,205.497 bed will contact at z=1.967500 probe: at 32.495,205.497 bed will contact at z=1.970000 probe: at 206.996,205.497 bed will contact at z=1.940000 probe: at 206.996,205.497 bed will contact at z=1.947500 probe: at 206.996,205.497 bed will contact at z=1.955000 probe: at 206.996,31.995 bed will contact at z=1.952500 probe: at 32.495,31.995 bed will contact at z=1.885000 probe: at 32.495,31.995 bed will contact at z=1.900000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=1.96750 front right screw : x=224.0, y=175.5, z=1.94750 : adjust CCW 00:02 rear right screw : x=224.0, y=2.0, z=1.95250 : adjust CCW 00:02 rear left screw : x=49.5, y=2.0, z=1.88500 : adjust CCW 00:10

History — 2 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-07-10T03:20:32.111279 PASS 340045000D51353234323830 2026-07-10T04:12:54
2026-07-10T03:18:04.487552 FAIL 340045000D51353234323830 2026-07-10T03:13:55