| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 05:13:59 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=380053000C51353234323830
|
| Home X | PASS | 05:14:24 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.9841 gap=1.0159 (chauffe, ignore)
tap 2: pos=357.5941 gap=1.4059 (1/4)
tap 3: pos=356.9969 gap=2.0031 (2/4)
tap 4: pos=357.1797 gap=1.8203 (3/4)
tap 5: pos=357.7769 gap=1.2231 fenetre=0.7800/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.3869 spread=0.7800mm (tol=0.0500). Zero pose en butee=357.0000
|
| Home Y | PASS | 05:14:55 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
|
| Motherboard fan | PASS | 05:15:31 | |
| Part fan | PASS | 05:15:34 | |
| Hotend fan | PASS | 05:15:36 | |
| Hotend heat 220°C | PASS | 05:15:36 | |
| Bed heat 60°C | PASS | 05:15:36 | |
| Cutter (feed+cut) | PASS | 05:17:12 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=356.9969 gap=2.0031 (1/4)
tap 3: pos=356.9969 gap=2.0031 (2/4)
tap 4: pos=356.9969 gap=2.0031 (3/4)
tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 05:17:26 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 05:20:11 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=356.9969 gap=2.0031 (1/4)
tap 3: pos=356.9969 gap=2.0031 (2/4)
tap 4: pos=356.9969 gap=2.0031 (3/4)
tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.0091 gap=1.9909 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Moving to tap point X=66.0 Y=276.0...
Probing with pressure switch...
probe at 65.996,275.995 is z=346.535000
probe at 65.996,275.995 is z=235.975000
Tap drift (diff=110.5600mm) — reset
probe at 65.996,275.995 is z=235.982500
Tap OK (diff=0.0075mm, stable 2/5)
probe at 65.996,275.995 is z=235.985000
Tap OK (diff=0.0025mm, stable 3/5)
probe at 65.996,275.995 is z=235.987500
Tap OK (diff=0.0025mm, stable 4/5)
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=235.9850 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 05:24:42 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8975, 385.9050, 385.9025, 385.9000, 385.9025, 385.9000, 385.8975, 385.9050, 385.9000, 385.9025, 385.9000, 385.9000, 385.9025, 385.9000, 385.9025
Moving to tap point X=66.0 Y=276.0...
Probing with pressure switch...
probe at 65.999,275.995 is z=394.765000
probe at 65.999,275.995 is z=397.485000
Tap rejete (vibration chassis, z=397.4850 > max-z_hop) -> pas de remontee, on poursuit la descente (1)
probe at 65.999,275.995 is z=394.530000
probe at 65.999,275.995 is z=397.247500
Tap rejete (vibration chassis, z=397.2475 > max-z_hop) -> pas de remontee, on poursuit la descente (2)
probe at 65.999,275.995 is z=74.890000
probe at 65.999,275.995 is z=0.880000
Tap drift (diff=74.0100mm) — reset
probe at 65.999,275.995 is z=0.892500
Tap drift (diff=0.0125mm) — reset
probe at 65.999,275.995 is z=0.895000
Tap OK (diff=0.0025mm, stable 2/5)
probe at 65.999,275.995 is z=0.897500
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=0.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0)
Z calibration complete!
probe at 65.999,275.995 is z=385.897500
probe at 65.999,275.995 is z=385.902500
Tap OK (diff=0.0050mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
probe at 65.999,275.995 is z=385.905000
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=385.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 65.999,275.995 is z=385.900000
Tap OK (diff=0.0025mm, stable 4/5)
VALIDATED: trigger_z=385.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Tap OK (diff=0.0000mm, stable 2/5)
VALIDATED: trigger_z=385.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 65.999,275.995 is z=385.895000
VALIDATED: trigger_z=385.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 65.999,275.995 is z=391.885000
probe at 65.999,275.995 is z=394.157500
Tap drift (diff=2.2725mm) — reset
probe at 65.999,275.995 is z=396.920000
|
| Screws tilt | PASS | 05:25:11 |
probe: at 67.000,271.004 bed will contact at z=2.205000
probe: at 67.000,271.004 bed will contact at z=2.207500
probe: at 267.996,271.004 bed will contact at z=2.282500
probe: at 267.996,271.004 bed will contact at z=2.277500
probe: at 267.996,71.995 bed will contact at z=2.322500
probe: at 267.996,71.995 bed will contact at z=2.320000
probe: at 267.996,71.995 bed will contact at z=2.315000
probe: at 67.000,71.995 bed will contact at z=2.302500
probe: at 67.000,71.995 bed will contact at z=2.307500
probe: at 67.000,71.995 bed will contact at z=2.315000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=84.0, y=241.0, z=2.20750
front right screw : x=285.0, y=241.0, z=2.28250 : adjust CW 00:09
rear right screw : x=285.0, y=42.0, z=2.32000 : adjust CW 00:14
rear left screw : x=84.0, y=42.0, z=2.30750 : adjust CW 00:12
|
| QC date | Result | QC pad (MAC) | Received (server) |
|---|---|---|---|
| 2026-07-14T05:13:59.327306 | PASS | 380053000C51353234323830 | 2026-07-17T06:07:23 |
| 2026-07-14T05:01:48.038513 | FAIL | 380053000C51353234323830 | 2026-07-17T06:07:19 |