← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

3A0045000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 0281AE52CB5F
Start : 2026-08-20T02:28:27.833969 · End : 2026-08-20T02:43:33.891156 · Duration : 906 s
Received (server) : 2026-08-20T03:04:34
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 02:28:28
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=3A0045000D51353234323830
Home X PASS 02:28:54
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=457.0091 gap=1.9909 (3/4) tap 5: pos=456.9847 gap=2.0153 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 02:29:30
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.6062 gap=1.3938 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 02:30:00
Part fan PASS 02:30:02
Hotend fan PASS 02:30:05
Hotend heat 220°C PASS 02:30:05
Bed heat 60°C PASS 02:30:24
Cutter (feed+cut) PASS 02:32:02
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=457.0091 gap=1.9909 (1/4) tap 3: pos=456.9847 gap=2.0153 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.8141 gap=2.1859 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9512 spread=0.1950mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 02:32:16
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 02:36:28
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.2041 gap=1.7959 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=457.1919 gap=1.8081 (3/4) tap 5: pos=456.8019 gap=2.1981 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=401.587500 probe at 49.995,339.999 is z=401.615000 Tap drift (diff=0.0275mm) — reset probe at 49.995,339.999 is z=401.665000 Tap drift (diff=0.0500mm) — reset probe at 49.995,339.999 is z=401.702500 Tap drift (diff=0.0375mm) — reset probe at 49.995,339.999 is z=401.667500 Tap drift (diff=0.0350mm) — reset probe at 49.995,339.999 is z=401.700000 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.995,339.999 is z=404.687500 Tap drift (diff=2.9875mm) — reset probe at 49.995,339.999 is z=401.637500 Tap drift (diff=3.0500mm) — reset probe at 49.995,339.999 is z=401.672500 probe at 49.995,339.999 is z=401.670000 probe at 49.995,339.999 is z=401.662500 Tap OK (diff=0.0075mm, stable 3/5) probe at 49.995,339.999 is z=401.660000 Tap OK (diff=0.0025mm, stable 4/5)
Z tap repeatability PASS 02:42:55 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=21.6225, 486.0950, 486.0975, 486.0975, 486.1050, 486.1025, 486.0975, 486.0975, 486.1025, 486.0975, 486.1000, 486.1000, 486.0750, 486.1000, 486.1000
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=494.447500 Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) probe at 49.998,339.999 is z=496.962500 Tap drift (diff=2.5150mm) — reset probe at 49.998,339.999 is z=499.085000 Tap rejete (vibration chassis, z=499.0850 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 49.998,339.999 is z=498.725000 Tap rejete (vibration chassis, z=498.7250 > max-z_hop) -> pas de remontee, on poursuit la descente (2) probe at 49.998,339.999 is z=448.732500 probe at 49.998,339.999 is z=399.337500 Tap drift (diff=49.3950mm) — reset probe at 49.998,339.999 is z=399.617500 Tap drift (diff=0.2800mm) — reset probe at 49.998,339.999 is z=339.005000 Tap drift (diff=60.6125mm) — reset probe at 49.998,339.999 is z=299.217500 Tap drift (diff=39.7875mm) — reset probe at 49.998,339.999 is z=279.157500 Tap drift (diff=20.0600mm) — reset probe at 49.998,339.999 is z=276.252500 Tap drift (diff=2.9050mm) — reset probe at 49.998,339.999 is z=272.260000 Tap drift (diff=3.9925mm) — reset probe at 49.998,339.999 is z=253.047500 Tap drift (diff=19.2125mm) — reset probe at 49.998,339.999 is z=256.000000 Tap drift (diff=2.9525mm) — reset probe at 49.998,339.999 is z=245.205000 Tap drift (diff=10.7950mm) — reset probe at 49.998,339.999 is z=21.617500 Tap drift (diff=223.5875mm) — reset probe at 49.998,339.999 is z=21.622500 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 49.998,339.999 is z=24.350000 Tap drift (diff=2.7275mm) — reset probe at 49.998,339.999 is z=21.620000
Screws tilt PASS 02:43:33
probe: at 54.997,328.001 bed will contact at z=1.892500 probe: at 54.997,328.001 bed will contact at z=1.887500 probe: at 54.997,328.001 bed will contact at z=1.890000 probe: at 380.001,328.001 bed will contact at z=1.880000 probe: at 380.001,328.001 bed will contact at z=1.890000 probe: at 380.001,328.001 bed will contact at z=1.887500 probe: at 380.001,101.996 bed will contact at z=1.870000 probe: at 380.001,101.996 bed will contact at z=1.882500 probe: at 54.997,101.996 bed will contact at z=1.882500 probe: at 54.997,101.996 bed will contact at z=1.885000 probe: at 217.505,214.498 bed will contact at z=1.997500 probe: at 217.505,214.498 bed will contact at z=1.990000 probe: at 217.505,214.498 bed will contact at z=2.020000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.89000 front right screw : x=397.0, y=298.0, z=1.88750 : adjust CCW 00:00 rear right screw : x=397.0, y=72.0, z=1.88250 : adjust CCW 00:01 rear left screw : x=72.0, y=72.0, z=1.88250 : adjust CCW 00:01 middle : x=234.5, y=184.5, z=1.99750 : adjust CW 00:13