SmartPi 1
SmartPi 2

3C0042000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 110V · 550W · SSR SSR10DA
QC pad (MAC) : 028103694A6F
Start : 2026-08-01T04:49:22.453462 · End : 2026-08-01T05:01:39.221643 · Duration : 736 s
Received (server) : 2026-08-01T05:02:10
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=550 ssr=SSR10DA lot=20260618 uid=2ACAAE

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 04:49:22
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=3C0042000D51353234323830
Home X PASS 04:49:48
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 04:50:22
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 04:50:46
Part fan PASS 04:50:48
Hotend fan PASS 04:50:50
Hotend heat 220°C PASS 04:50:50
Bed heat 60°C PASS 04:51:40
Cutter (feed+cut) PASS 04:53:08
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 04:53:23
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 04:56:23
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-30.1919 gap=1.8081 (2/4) tap 4: pos=-30.5819 gap=1.4181 (3/4) tap 5: pos=-30.1919 gap=1.8081 fenetre=0.5850/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.2406 spread=0.5850mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,340.003 is z=408.607500 probe at 49.995,340.003 is z=408.612500 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.995,340.003 is z=408.615000 Tap OK (diff=0.0025mm, stable 3/5) probe at 49.995,340.003 is z=408.617500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=408.6175 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 05:00:53 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1750, 486.1025, 486.1000, 486.1025, 486.1000, 486.1025, 486.0975, 486.0975, 486.1025, 486.1025, 486.0975, 486.0975, 486.1050, 486.1000, 486.1000
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,340.003 is z=1.145000 probe at 49.998,340.003 is z=1.167500 Tap drift (diff=0.0225mm) — reset probe at 49.998,340.003 is z=1.172500 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.998,340.003 is z=1.175000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=1.1750 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,340.003 is z=486.100000 Tap OK (diff=0.0000mm, stable 2/5) probe at 49.998,340.003 is z=486.102500 probe at 49.998,340.003 is z=486.105000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,340.003 is z=486.097500 Tap OK (diff=0.0000mm, stable 3/5) VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,340.003 is z=486.095000 Tap OK (diff=0.0025mm, stable 2/5) VALIDATED: trigger_z=486.0975 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,340.003 is z=486.092500 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0075mm, stable 2/5)
Screws tilt PASS 05:01:39
probe: at 54.997,315.001 bed will contact at z=2.107500 probe: at 54.997,315.001 bed will contact at z=2.105000 probe: at 54.997,315.001 bed will contact at z=2.120000 probe: at 380.001,315.001 bed will contact at z=2.150000 probe: at 380.001,315.001 bed will contact at z=2.130000 probe: at 380.001,315.001 bed will contact at z=2.140000 probe: at 380.001,83.000 bed will contact at z=1.992500 probe: at 380.001,83.000 bed will contact at z=1.990000 probe: at 380.001,83.000 bed will contact at z=2.017500 probe: at 54.997,83.000 bed will contact at z=2.032500 probe: at 54.997,83.000 bed will contact at z=2.030000 probe: at 54.997,83.000 bed will contact at z=2.042500 probe: at 217.505,202.498 bed will contact at z=2.135000 probe: at 217.505,202.498 bed will contact at z=2.107500 probe: at 217.505,202.498 bed will contact at z=2.045000 Probe samples exceed tolerance. Retrying... probe: at 217.505,202.498 bed will contact at z=2.120000 probe: at 217.505,202.498 bed will contact at z=2.165000 probe: at 217.505,202.498 bed will contact at z=2.090000 probe: at 217.505,202.498 bed will contact at z=2.127500 probe: at 217.505,202.498 bed will contact at z=2.117500 probe: at 217.505,202.498 bed will contact at z=2.100000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=285.0, z=2.10750 front right screw : x=397.0, y=285.0, z=2.14000 : adjust CW 00:04 rear right screw : x=397.0, y=53.0, z=1.99250 : adjust CCW 00:14 rear left screw : x=72.0, y=53.0, z=2.03250 : adjust CCW 00:09 rear left screw : x=234.5, y=172.5, z=2.11750 : adjust CW 00:01