| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 06:35:25 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=3D005E000C51353234323830
|
| Home X | PASS | 06:35:51 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 06:36:35 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1 rejete: aucun contact sur 7.0mm (No trigger on probe after full movement)
tap 2 rejete: aucun contact sur 7.0mm (No trigger on probe after full movement)
YUMI_SENSORLESS_HOME Y: home de base suspect (pas de contact) -> re-home de recuperation 1/2
tap 3: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 4: pos=-17.9969 gap=2.0031 (1/4)
tap 5: pos=-17.9969 gap=2.0031 (2/4)
tap 6: pos=-17.9969 gap=2.0031 (3/4)
tap 7: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (2 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
|
| Motherboard fan | PASS | 06:37:30 | |
| Part fan | PASS | 06:37:32 | |
| Hotend fan | PASS | 06:37:34 | |
| Hotend heat 220°C | PASS | 06:37:34 | |
| Bed heat 60°C | PASS | 06:38:33 | |
| Cutter (feed+cut) | PASS | 06:40:02 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore)
tap 2: pos=457.1797 gap=1.8203 (1/4)
tap 3: pos=457.0091 gap=1.9909 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.1828/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.0456 spread=0.1828mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-17.9847 gap=2.0153 (1/4)
tap 3: pos=-18.0091 gap=1.9909 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0244/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=-18.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 06:40:16 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 06:43:23 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1 rejete: cible atteinte sans buter (gap=0.0653)
tap 2 rejete: cible atteinte sans buter (gap=0.0531)
YUMI_SENSORLESS_HOME X: home de base suspect (pas de contact) -> re-home de recuperation 1/2
tap 3: pos=457.5697 gap=1.4303 (chauffe, ignore)
tap 4: pos=457.1797 gap=1.8203 (1/4)
tap 5: pos=457.0091 gap=1.9909 (2/4)
tap 6: pos=456.8019 gap=2.1981 (3/4)
tap 7: pos=457.1919 gap=1.8081 fenetre=0.3900/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (2 rejetes) -> moyenne=457.0456 spread=0.3900mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9847 gap=2.0153 (3/4)
tap 5: pos=-18.0091 gap=1.9909 fenetre=0.0244/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=-18.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,339.999 is z=475.617500
probe at 49.995,339.999 is z=411.365000
Tap drift (diff=64.2525mm) — reset
probe at 49.995,339.999 is z=411.377500
Tap drift (diff=0.0125mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
probe at 49.995,339.999 is z=411.385000
Tap OK (diff=0.0075mm, stable 3/5)
probe at 49.995,339.999 is z=411.375000
Tap OK (diff=0.0100mm, stable 4/5)
probe at 49.995,339.999 is z=411.380000
Tap OK (diff=0.0050mm, stable 5/5)
VALIDATED: trigger_z=411.3800 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 06:47:57 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1400, 486.1100, 486.0950, 486.1075, 486.1000, 486.1000, 486.1050, 486.0975, 486.1025, 486.1000, 486.1000, 486.1025, 486.1000, 486.1000, 486.1025
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,339.999 is z=1.125000
probe at 49.998,339.999 is z=1.135000
Tap drift (diff=0.0100mm) — reset
probe at 49.998,339.999 is z=1.132500
Tap OK (diff=0.0025mm, stable 2/5)
probe at 49.998,339.999 is z=1.142500
probe at 49.998,339.999 is z=1.145000
probe at 49.998,339.999 is z=1.140000
Tap OK (diff=0.0050mm, stable 3/5)
probe at 49.998,339.999 is z=1.147500
Tap OK (diff=0.0075mm, stable 4/5)
Tap OK (diff=0.0075mm, stable 5/5)
VALIDATED: trigger_z=1.1400 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
probe at 49.998,339.999 is z=486.100000
probe at 49.998,339.999 is z=486.105000
Tap OK (diff=0.0050mm, stable 2/5)
probe at 49.998,339.999 is z=486.110000
probe at 49.998,339.999 is z=486.112500
Tap OK (diff=0.0025mm, stable 4/5)
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=486.1100 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,339.999 is z=486.097500
Tap OK (diff=0.0075mm, stable 2/5)
probe at 49.998,339.999 is z=486.102500
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
probe at 49.998,339.999 is z=486.095000
VALIDATED: trigger_z=486.0950 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,339.999 is z=486.107500
Tap OK (diff=0.0000mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=486.1075 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
VALIDATED: trigger_z=486.0975 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
|
| Screws tilt | PASS | 06:48:34 |
probe: at 54.997,328.001 bed will contact at z=2.617500
probe: at 54.997,328.001 bed will contact at z=2.627500
probe: at 380.001,328.001 bed will contact at z=2.582500
probe: at 380.001,328.001 bed will contact at z=2.580000
probe: at 380.001,328.001 bed will contact at z=2.592500
probe: at 380.001,101.996 bed will contact at z=2.625000
probe: at 380.001,101.996 bed will contact at z=2.617500
probe: at 54.997,101.996 bed will contact at z=2.622500
probe: at 54.997,101.996 bed will contact at z=2.627500
probe: at 54.997,101.996 bed will contact at z=2.630000
probe: at 217.505,214.498 bed will contact at z=2.637500
probe: at 217.505,214.498 bed will contact at z=2.640000
probe: at 217.505,214.498 bed will contact at z=2.645000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=298.0, z=2.62750
front right screw : x=397.0, y=298.0, z=2.58250 : adjust CCW 00:05
rear right screw : x=397.0, y=72.0, z=2.62500 : adjust CCW 00:00
rear left screw : x=72.0, y=72.0, z=2.62750 : adjust CCW 00:00
middle : x=234.5, y=184.5, z=2.64000 : adjust CW 00:02
|
Moves this report to the trash — you can restore it from /trash.