| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 04:31:17 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=3E005E000C51353234323830
|
| Home X | PASS | 04:31:43 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 04:32:17 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
|
| Motherboard fan | PASS | 04:32:26 | |
| Part fan | PASS | 04:32:30 | |
| Hotend fan | PASS | 04:32:32 | |
| Hotend heat 220°C | PASS | 04:32:35 | |
| Bed heat 60°C | PASS | 04:33:24 | |
| Cutter (feed+cut) | PASS | 04:34:50 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 04:35:09 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 100mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 04:38:05 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,339.999 is z=407.470000
probe at 49.995,339.999 is z=407.527500
Tap drift (diff=0.0575mm) — reset
probe at 49.995,339.999 is z=407.537500
Tap drift (diff=0.0100mm) — reset
probe at 49.995,339.999 is z=407.542500
Tap OK (diff=0.0050mm, stable 2/5)
probe at 49.995,339.999 is z=407.545000
Tap OK (diff=0.0025mm, stable 3/5)
probe at 49.995,339.999 is z=407.550000
Tap OK (diff=0.0050mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=407.5500 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 04:43:04 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8900, 485.8975, 485.9050, 485.9075, 485.9025, 485.9025, 485.9000, 485.9000, 485.9025, 485.9000, 485.9025, 485.9000, 485.9000, 485.9025, 485.8975
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,339.999 is z=495.107500
probe at 49.998,339.999 is z=497.150000
Tap rejete (vibration chassis, z=497.1500 > max-z_hop) -> pas de remontee, on poursuit la descente (1)
probe at 49.998,339.999 is z=0.725000
probe at 49.998,339.999 is z=0.872500
Tap drift (diff=0.1475mm) — reset
probe at 49.998,339.999 is z=0.877500
Tap OK (diff=0.0050mm, stable 2/5)
probe at 49.998,339.999 is z=0.882500
Tap OK (diff=0.0050mm, stable 3/5)
probe at 49.998,339.999 is z=0.887500
Tap OK (diff=0.0050mm, stable 4/5)
probe at 49.998,339.999 is z=0.890000
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=0.8900 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
probe at 49.998,339.999 is z=485.872500
probe at 49.998,339.999 is z=485.887500
Tap drift (diff=0.0150mm) — reset
probe at 49.998,339.999 is z=485.892500
probe at 49.998,339.999 is z=485.895000
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0025mm, stable 4/5)
probe at 49.998,339.999 is z=485.897500
Tap OK (diff=0.0050mm, stable 5/5)
VALIDATED: trigger_z=485.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 49.998,339.999 is z=485.882500
probe at 49.998,339.999 is z=485.900000
Tap drift (diff=0.0175mm) — reset
probe at 49.998,339.999 is z=485.905000
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=485.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 49.998,339.999 is z=485.902500
Tap OK (diff=0.0025mm, stable 2/5)
probe at 49.998,339.999 is z=485.907500
|
| Screws tilt | PASS | 04:43:43 |
probe: at 54.997,328.001 bed will contact at z=1.392500
probe: at 54.997,328.001 bed will contact at z=1.400000
probe: at 54.997,328.001 bed will contact at z=1.410000
probe: at 380.001,328.001 bed will contact at z=1.312500
probe: at 380.001,328.001 bed will contact at z=1.320000
probe: at 380.001,328.001 bed will contact at z=1.330000
probe: at 380.001,101.996 bed will contact at z=1.247500
probe: at 380.001,101.996 bed will contact at z=1.262500
probe: at 380.001,101.996 bed will contact at z=1.257500
probe: at 54.997,101.996 bed will contact at z=1.397500
probe: at 54.997,101.996 bed will contact at z=1.402500
probe: at 217.505,214.498 bed will contact at z=1.410000
probe: at 217.505,214.498 bed will contact at z=1.447500
probe: at 217.505,214.498 bed will contact at z=1.417500
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=298.0, z=1.40000
front right screw : x=397.0, y=298.0, z=1.32000 : adjust CCW 00:10
rear right screw : x=397.0, y=72.0, z=1.25750 : adjust CCW 00:17
rear left screw : x=72.0, y=72.0, z=1.40250 : adjust CW 00:00
middle : x=234.5, y=184.5, z=1.41750 : adjust CW 00:02
|