| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 07:52:21 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=500;ssr=SSR10DA;lot=20260618;uid=B3D7BD
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=41005B000C51353234323830
|
| Home X | PASS | 07:52:46 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.7769 gap=1.2231 (chauffe, ignore)
tap 2: pos=357.1919 gap=1.8081 (1/4)
tap 3: pos=356.8019 gap=2.1981 (2/4)
tap 4: pos=357.1919 gap=1.8081 (3/4)
tap 5: pos=356.9969 gap=2.0031 fenetre=0.3900/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.0456 spread=0.3900mm (tol=0.0500). Zero pose en butee=357.0000
|
| Home Y | PASS | 07:53:23 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-30.3869 gap=1.6131 (2/4)
tap 4: pos=-30.3869 gap=1.6131 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.3900/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.1919 spread=0.3900mm (tol=0.0500). Zero pose en butee=-30.0000
|
| Motherboard fan | PASS | 07:53:33 | |
| Part fan | PASS | 07:53:35 | |
| Hotend fan | PASS | 07:53:37 | |
| Hotend heat 220°C | PASS | 07:53:37 | |
| Bed heat 60°C | PASS | 07:53:37 | |
| Cutter (feed+cut) | PASS | 07:55:14 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=356.9969 gap=2.0031 (1/4)
tap 3: pos=356.9969 gap=2.0031 (2/4)
tap 4: pos=357.1919 gap=1.8081 (3/4)
tap 5: pos=356.8019 gap=2.1981 fenetre=0.3900/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=357.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 07:55:37 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 125mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 07:58:43 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=356.9969 gap=2.0031 (1/4)
tap 3: pos=356.9969 gap=2.0031 (2/4)
tap 4: pos=356.9969 gap=2.0031 (3/4)
tap 5: pos=357.1919 gap=1.8081 fenetre=0.1950/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.0456 spread=0.1950mm (tol=0.0500). Zero pose en butee=357.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-30.1919 gap=1.8081 (1/4)
tap 3: pos=-30.5819 gap=1.4181 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-30.1919 gap=1.8081 fenetre=0.5850/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.2406 spread=0.5850mm (tol=0.0500). Zero pose en butee=-30.0000
Moving to tap point X=66.0 Y=276.0...
Probing with pressure switch...
probe at 65.996,275.995 is z=311.355000
Tap OK (diff=0.0000mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
probe at 65.996,275.995 is z=311.357500
Tap OK (diff=0.0025mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=311.3575 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 08:03:07 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9025, 385.9075, 385.9000, 385.9025, 385.9000, 385.9025, 385.9025, 385.8975, 385.9125, 385.9050, 385.9025, 385.8975, 385.9000, 385.9000, 385.9000
Moving to tap point X=66.0 Y=276.0...
Probing with pressure switch...
probe at 65.999,275.995 is z=0.892500
probe at 65.999,275.995 is z=0.897500
Tap OK (diff=0.0050mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
probe at 65.999,275.995 is z=0.902500
Tap OK (diff=0.0050mm, stable 5/5)
VALIDATED: trigger_z=0.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0)
Z calibration complete!
probe at 65.999,275.995 is z=385.897500
Tap OK (diff=0.0000mm, stable 2/5)
probe at 65.999,275.995 is z=385.900000
Tap OK (diff=0.0025mm, stable 3/5)
probe at 65.999,275.995 is z=385.907500
Tap OK (diff=0.0075mm, stable 5/5)
VALIDATED: trigger_z=385.9075 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 65.999,275.995 is z=385.890000
probe at 65.999,275.995 is z=385.892500
Tap OK (diff=0.0025mm, stable 2/5)
Tap OK (diff=0.0050mm, stable 3/5)
Tap OK (diff=0.0025mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=385.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 65.999,275.995 is z=385.902500
Tap drift (diff=0.0100mm) — reset
probe at 65.999,275.995 is z=385.905000
Tap OK (diff=0.0075mm, stable 4/5)
VALIDATED: trigger_z=385.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 65.999,275.995 is z=385.895000
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=385.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 65.999,275.995 is z=385.915000
Tap OK (diff=0.0075mm, stable 2/5)
probe at 65.999,275.995 is z=385.910000
probe at 65.999,275.995 is z=385.912500
VALIDATED: trigger_z=385.9125 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 65.999,275.995 is z=385.887500
|
| Screws tilt | PASS | 08:04:08 |
probe: at 67.000,271.004 bed will contact at z=1.670000
probe: at 67.000,271.004 bed will contact at z=1.595000
Probe samples exceed tolerance. Retrying...
probe: at 67.000,271.004 bed will contact at z=1.637500
probe: at 67.000,271.004 bed will contact at z=1.617500
probe: at 67.000,271.004 bed will contact at z=1.630000
probe: at 267.996,271.004 bed will contact at z=1.752500
probe: at 267.996,271.004 bed will contact at z=1.710000
probe: at 267.996,271.004 bed will contact at z=1.597500
probe: at 267.996,271.004 bed will contact at z=1.677500
probe: at 267.996,271.004 bed will contact at z=1.625000
probe: at 267.996,271.004 bed will contact at z=1.642500
probe: at 267.996,271.004 bed will contact at z=1.675000
probe: at 267.996,271.004 bed will contact at z=1.577500
probe: at 267.996,271.004 bed will contact at z=1.622500
probe: at 267.996,271.004 bed will contact at z=1.620000
probe: at 267.996,271.004 bed will contact at z=1.585000
probe: at 267.996,71.995 bed will contact at z=1.697500
probe: at 267.996,71.995 bed will contact at z=1.665000
probe: at 267.996,71.995 bed will contact at z=1.642500
probe: at 267.996,71.995 bed will contact at z=1.660000
probe: at 267.996,71.995 bed will contact at z=1.695000
probe: at 267.996,71.995 bed will contact at z=1.722500
probe: at 267.996,71.995 bed will contact at z=1.687500
probe: at 267.996,71.995 bed will contact at z=1.652500
probe: at 267.996,71.995 bed will contact at z=1.715000
probe: at 267.996,71.995 bed will contact at z=1.692500
probe: at 267.996,71.995 bed will contact at z=1.667500
probe: at 267.996,71.995 bed will contact at z=1.700000
probe: at 67.000,71.995 bed will contact at z=1.647500
probe: at 67.000,71.995 bed will contact at z=1.680000
probe: at 67.000,71.995 bed will contact at z=1.712500
probe: at 67.000,71.995 bed will contact at z=1.682500
probe: at 67.000,71.995 bed will contact at z=1.672500
probe: at 67.000,71.995 bed will contact at z=1.697500
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=84.0, y=241.0, z=1.63000
front right screw : x=285.0, y=241.0, z=1.59750 : adjust CCW 00:04
rear right screw : x=285.0, y=42.0, z=1.69250 : adjust CW 00:08
rear left screw : x=84.0, y=42.0, z=1.68250 : adjust CW 00:06
|
Moves this report to the trash — you can restore it from /trash.