SmartPi 1
SmartPi 2

420059000C51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 028103694A6F
Start : 2026-08-13T14:42:37.744993 · End : 2026-08-13T14:58:47.688721 · Duration : 969 s
Received (server) : 2026-08-14T02:00:46
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 14:42:37
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=420059000C51353234323830
Home X PASS 14:43:04
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=467.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=466.9969 gap=2.0031 (1/4) tap 3: pos=466.9969 gap=2.0031 (2/4) tap 4: pos=466.9969 gap=2.0031 (3/4) tap 5: pos=466.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=466.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=467.0000
Home Y PASS 14:43:40
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-21.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-21.7647 gap=1.2353 (1/4) tap 3: pos=-21.7891 gap=1.2109 (2/4) tap 4: pos=-21.7769 gap=1.2231 (3/4) tap 5: pos=-21.7769 gap=1.2231 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-21.7769 spread=0.0244mm (tol=0.0500). Zero pose en butee=-21.0000
Motherboard fan PASS 14:43:44
Part fan PASS 14:43:47
Hotend fan PASS 14:43:49
Hotend heat 220°C PASS 14:44:04
Bed heat 60°C PASS 14:44:05
Cutter (feed+cut) PASS 14:45:35
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=467.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=466.9969 gap=2.0031 (1/4) tap 3: pos=466.9969 gap=2.0031 (2/4) tap 4: pos=466.9969 gap=2.0031 (3/4) tap 5: pos=466.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=466.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=467.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-21.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=-21.7769 gap=1.2231 (1/4) tap 3: pos=-21.7769 gap=1.2231 (2/4) tap 4: pos=-21.7769 gap=1.2231 (3/4) tap 5: pos=-21.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-21.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-21.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 14:45:50
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 14:53:34
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=467.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=466.9969 gap=2.0031 (1/4) tap 3: pos=466.9969 gap=2.0031 (2/4) tap 4: pos=466.9969 gap=2.0031 (3/4) tap 5: pos=466.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=466.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=467.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-21.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=-21.7769 gap=1.2231 (1/4) tap 3: pos=-21.7891 gap=1.2109 (2/4) tap 4: pos=-21.7769 gap=1.2231 (3/4) tap 5: pos=-21.7769 gap=1.2231 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-21.7799 spread=0.0122mm (tol=0.0500). Zero pose en butee=-21.0000 Moving to tap point X=56.0 Y=334.0... Probing with pressure switch... probe at 55.998,334.001 is z=408.845000 probe at 55.998,334.001 is z=408.867500 Tap drift (diff=0.0225mm) — reset Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 55.998,334.001 is z=408.870000 Tap OK (diff=0.0025mm, stable 4/5) probe at 55.998,334.001 is z=408.875000 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=408.8750 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (56.0, 334.0) ~ point de tap (56.0, 334.0) Z calibration complete!
Z tap repeatability PASS 14:58:04 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1150, 486.1100, 486.1025, 486.1025, 486.1000, 486.1000, 486.1025, 486.1000, 486.1025, 486.1000, 486.1000, 486.1000, 486.1000, 486.1025, 486.0950
Moving to tap point X=56.0 Y=334.0... Probing with pressure switch... probe at 56.001,334.001 is z=1.100000 probe at 56.001,334.001 is z=1.110000 Tap drift (diff=0.0100mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 56.001,334.001 is z=1.115000 Tap OK (diff=0.0050mm, stable 3/5) probe at 56.001,334.001 is z=1.112500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=1.1150 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (56.0, 334.0) ~ point de tap (56.0, 334.0) Z calibration complete! probe at 56.001,334.001 is z=486.097500 probe at 56.001,334.001 is z=486.102500 Tap OK (diff=0.0050mm, stable 2/5) probe at 56.001,334.001 is z=486.110000 Tap OK (diff=0.0075mm, stable 3/5) probe at 56.001,334.001 is z=486.107500 VALIDATED: trigger_z=486.1100 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 56.001,334.001 is z=486.100000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0000mm, stable 3/5) VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 56.001,334.001 is z=486.095000 VALIDATED: trigger_z=486.0950 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Screws tilt PASS 14:58:47
probe: at 56.003,334.994 bed will contact at z=2.855000 probe: at 56.003,334.994 bed will contact at z=2.852500 probe: at 56.003,334.994 bed will contact at z=2.857500 probe: at 388.002,334.994 bed will contact at z=2.867500 probe: at 388.002,334.994 bed will contact at z=2.915000 probe: at 388.002,334.994 bed will contact at z=2.955000 Probe samples exceed tolerance. Retrying... probe: at 388.002,334.994 bed will contact at z=2.897500 probe: at 388.002,334.994 bed will contact at z=2.917500 probe: at 388.002,334.994 bed will contact at z=2.892500 probe: at 388.002,110.001 bed will contact at z=2.835000 probe: at 388.002,110.001 bed will contact at z=2.780000 probe: at 388.002,110.001 bed will contact at z=2.805000 probe: at 388.002,110.001 bed will contact at z=2.785000 probe: at 388.002,110.001 bed will contact at z=2.870000 probe: at 388.002,110.001 bed will contact at z=2.790000 probe: at 388.002,110.001 bed will contact at z=2.830000 probe: at 56.003,110.001 bed will contact at z=2.875000 probe: at 56.003,110.001 bed will contact at z=2.877500 probe: at 221.996,222.004 bed will contact at z=2.900000 probe: at 221.996,222.004 bed will contact at z=2.920000 probe: at 221.996,222.004 bed will contact at z=2.872500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=73.0, y=305.0, z=2.85500 front right screw : x=405.0, y=305.0, z=2.89750 : adjust CW 00:05 rear right screw : x=405.0, y=80.0, z=2.79000 : adjust CCW 00:08 rear left screw : x=73.0, y=80.0, z=2.87750 : adjust CW 00:03 rear middle screw : x=239.0, y=192.0, z=2.90000 : adjust CW 00:05