| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 06:34:08 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=430052000C51353234323830
|
| Home X | PASS | 06:34:34 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.5941 gap=1.4059 (chauffe, ignore)
tap 2: pos=456.8141 gap=2.1859 (1/4)
tap 3: pos=457.1797 gap=1.8203 (2/4)
tap 4: pos=457.5941 gap=1.4059 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.7800/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.1462 spread=0.7800mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 06:35:10 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.8012 gap=1.1988 (chauffe, ignore)
tap 2: pos=-18.3991 gap=1.6009 (1/4)
tap 3: pos=-18.3747 gap=1.6253 (2/4)
tap 4: pos=-18.7769 gap=1.2231 (3/4)
tap 5: pos=-18.7769 gap=1.2231 fenetre=0.4022/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.5819 spread=0.4022mm (tol=0.0500). Zero pose en butee=-18.0000
|
| Motherboard fan | PASS | 06:35:20 | |
| Part fan | PASS | 06:35:23 | |
| Hotend fan | PASS | 06:35:25 | |
| Hotend heat 220°C | PASS | 06:35:30 | |
| Bed heat 60°C | PASS | 06:35:39 | |
| Cutter (feed+cut) | PASS | 06:37:19 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore)
tap 2: pos=-18.3991 gap=1.6009 (1/4)
tap 3: pos=-18.3747 gap=1.6253 (2/4)
tap 4: pos=-18.7769 gap=1.2231 (3/4)
tap 5: pos=-18.3991 gap=1.6009 fenetre=0.4022/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.4874 spread=0.4022mm (tol=0.0500). Zero pose en butee=-18.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 06:37:33 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 06:40:19 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore)
tap 2: pos=-18.7769 gap=1.2231 (1/4)
tap 3: pos=-18.7769 gap=1.2231 (2/4)
tap 4: pos=-18.7769 gap=1.2231 (3/4)
tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,339.999 is z=406.985000
probe at 49.995,339.999 is z=406.987500
Tap OK (diff=0.0025mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=406.9875 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 06:44:56 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=41.4325, 486.1000, 486.1050, 486.1050, 486.1000, 486.1025, 486.1100, 486.1000, 486.1025, 486.1000, 486.0975, 486.1025, 486.1000, 486.1000, 486.1050
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,339.999 is z=495.587500
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
probe at 49.998,339.999 is z=498.237500
Tap rejete (vibration chassis, z=498.2375 > max-z_hop) -> pas de remontee, on poursuit la descente (1)
probe at 49.998,339.999 is z=406.855000
probe at 49.998,339.999 is z=41.430000
Tap drift (diff=365.4250mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
probe at 49.998,339.999 is z=41.432500
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=41.4325 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
probe at 49.998,339.999 is z=486.102500
probe at 49.998,339.999 is z=486.100000
Tap OK (diff=0.0025mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,339.999 is z=486.105000
VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Tap OK (diff=0.0025mm, stable 4/5)
probe at 49.998,339.999 is z=486.110000
Tap OK (diff=0.0100mm, stable 2/5)
Tap drift (diff=0.0100mm) — reset
Tap OK (diff=0.0050mm, stable 2/5)
Tap OK (diff=0.0050mm, stable 3/5)
Tap OK (diff=0.0100mm, stable 4/5)
VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,339.999 is z=486.107500
Tap OK (diff=0.0025mm, stable 3/5)
VALIDATED: trigger_z=486.1100 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,339.999 is z=486.097500
VALIDATED: trigger_z=486.0975 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Tap OK (diff=0.0050mm, stable 5/5)
|
| Screws tilt | PASS | 06:45:33 |
probe: at 54.997,328.001 bed will contact at z=2.625000
probe: at 54.997,328.001 bed will contact at z=2.627500
probe: at 54.997,328.001 bed will contact at z=2.632500
probe: at 380.001,328.001 bed will contact at z=2.592500
probe: at 380.001,328.001 bed will contact at z=2.590000
probe: at 380.001,101.996 bed will contact at z=2.642500
probe: at 380.001,101.996 bed will contact at z=2.632500
probe: at 380.001,101.996 bed will contact at z=2.647500
probe: at 54.997,101.996 bed will contact at z=2.712500
probe: at 54.997,101.996 bed will contact at z=2.702500
probe: at 54.997,101.996 bed will contact at z=2.692500
probe: at 217.505,214.498 bed will contact at z=2.685000
probe: at 217.505,214.498 bed will contact at z=2.662500
probe: at 217.505,214.498 bed will contact at z=2.672500
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=298.0, z=2.62750
front right screw : x=397.0, y=298.0, z=2.59250 : adjust CCW 00:04
rear right screw : x=397.0, y=72.0, z=2.64250 : adjust CW 00:02
rear left screw : x=72.0, y=72.0, z=2.70250 : adjust CW 00:09
middle : x=234.5, y=184.5, z=2.67250 : adjust CW 00:05
|