← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

44005B000C51353234323830

PASS Grade A Grade B
Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 02813C788EB7
Start : 2026-06-29T05:40:06.100164 · End : 2026-06-29T05:51:40.069574 · Duration : 693 s
Received (server) : 2026-06-29T05:52:15
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 05:40:20
Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 Unknown command:"_SET_TIMELAPSE_SETUP" Unknown command:"HYPERLAPSE" [mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=44005B000C51353234323830
Home X PASS 05:40:41
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.3747 gap=1.6253 (chauffe, ignore) tap 2: pos=256.1919 gap=1.8081 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=256.0456 spread=0.1950mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 05:41:16
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 05:41:21
Part fan PASS 05:41:23
Hotend fan PASS 05:41:25
Hotend heat 220°C PASS 05:41:25
Bed heat 60°C PASS 05:41:25
Cutter (feed+cut) PASS 05:42:56
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=256.1919 gap=1.8081 (1/4) tap 3: pos=255.8019 gap=2.1981 (2/4) tap 4: pos=256.1919 gap=1.8081 (3/4) tap 5: pos=255.8019 gap=2.1981 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 05:43:07
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 05:45:53
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=256.1919 gap=1.8081 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=256.0456 spread=0.1950mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=83.687500 probe at 31.003,211.998 is z=83.690000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 31.003,211.998 is z=83.692500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=83.6900 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 05:50:55 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8475, 255.9800, 255.9050, 255.9025, 255.9025, 255.9075, 255.9025, 255.8950, 256.0275, 255.9050, 255.9025, 255.9025, 255.8975, 255.9000, 255.9025
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=0.845000 probe at 30.994,211.998 is z=0.847500 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 30.994,211.998 is z=0.850000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=0.8475 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.970000 probe at 30.994,211.998 is z=255.972500 probe at 30.994,211.998 is z=255.975000 Tap OK (diff=0.0025mm, stable 3/5) probe at 30.994,211.998 is z=255.977500 probe at 30.994,211.998 is z=255.980000 VALIDATED: trigger_z=255.9800 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.905000 probe at 30.994,211.998 is z=255.902500 Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=255.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.900000 VALIDATED: trigger_z=255.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.897500 Tap OK (diff=0.0050mm, stable 2/5) probe at 30.994,211.998 is z=255.907500 VALIDATED: trigger_z=255.9075 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.892500 Tap OK (diff=0.0050mm, stable 3/5) probe at 30.994,211.998 is z=255.895000 Tap OK (diff=0.0075mm, stable 4/5) VALIDATED: trigger_z=255.8950 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=263.215000 Tap drift (diff=7.3125mm) — reset probe at 30.994,211.998 is z=256.045000 Tap drift (diff=0.1425mm) — reset probe at 30.994,211.998 is z=256.042500
Screws tilt PASS 05:51:40
probe: at 32.495,205.497 bed will contact at z=2.465000 probe: at 32.495,205.497 bed will contact at z=2.700000 Probe samples exceed tolerance. Retrying... probe: at 32.495,205.497 bed will contact at z=2.690000 probe: at 32.495,205.497 bed will contact at z=2.670000 probe: at 32.495,205.497 bed will contact at z=2.607500 probe: at 32.495,205.497 bed will contact at z=2.627500 probe: at 32.495,205.497 bed will contact at z=2.625000 probe: at 32.495,205.497 bed will contact at z=2.605000 probe: at 206.996,205.497 bed will contact at z=3.595000 probe: at 206.996,205.497 bed will contact at z=3.540000 probe: at 206.996,205.497 bed will contact at z=3.545000 probe: at 206.996,205.497 bed will contact at z=3.530000 probe: at 206.996,205.497 bed will contact at z=3.515000 probe: at 206.996,31.995 bed will contact at z=4.515000 probe: at 206.996,31.995 bed will contact at z=4.607500 probe: at 206.996,31.995 bed will contact at z=4.590000 probe: at 206.996,31.995 bed will contact at z=4.602500 probe: at 206.996,31.995 bed will contact at z=4.597500 probe: at 32.495,31.995 bed will contact at z=4.215000 probe: at 32.495,31.995 bed will contact at z=4.227500 probe: at 32.495,31.995 bed will contact at z=4.272500 probe: at 32.495,31.995 bed will contact at z=4.237500 probe: at 32.495,31.995 bed will contact at z=4.240000 probe: at 32.495,31.995 bed will contact at z=4.185000 probe: at 32.495,31.995 bed will contact at z=4.195000 probe: at 32.495,31.995 bed will contact at z=4.260000 probe: at 32.495,31.995 bed will contact at z=4.222500 probe: at 32.495,31.995 bed will contact at z=4.190000 probe: at 32.495,31.995 bed will contact at z=4.220000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=2.62500 front right screw : x=224.0, y=175.5, z=3.53000 : adjust CW 01:49 rear right screw : x=224.0, y=2.0, z=4.59750 : adjust CW 03:57 rear left screw : x=49.5, y=2.0, z=4.22000 : adjust CW 03:11

History — 2 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-06-29T05:40:06.100164 PASS 44005B000C51353234323830 2026-06-29T05:52:15
2026-06-29T05:32:18.227508 FAIL 44005B000C51353234323830 2026-06-29T05:34:37