← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

450041000D51353234323830

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 0281D225B2A9
Start : 2026-07-13T06:18:11.734773 · End : 2026-07-13T06:31:06.739946 · Duration : 775 s
Received (server) : 2026-07-17T06:07:37
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 06:18:11
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=450041000D51353234323830
Home X PASS 06:18:33
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=357.1919 gap=1.8081 (1/4) tap 3: pos=356.8019 gap=2.1981 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 06:19:04
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.2041 gap=1.7959 (chauffe, ignore) tap 2: pos=-30.5819 gap=1.4181 (1/4) tap 3: pos=-30.1919 gap=1.8081 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.5819 gap=1.4181 fenetre=0.5850/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.5331 spread=0.5850mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 06:19:20
Part fan PASS 06:19:23
Hotend fan PASS 06:19:26
Hotend heat 220°C PASS 06:19:27
Bed heat 60°C PASS 06:19:32
Cutter (feed+cut) PASS 06:21:06
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=356.8019 gap=2.1981 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=357.1919 gap=1.8081 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-30.5819 gap=1.4181 (1/4) tap 3: pos=-30.3869 gap=1.6131 (2/4) tap 4: pos=-30.3869 gap=1.6131 (3/4) tap 5: pos=-30.1919 gap=1.8081 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.3869 spread=0.3900mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 06:21:20
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 06:24:23
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-30.1919 gap=1.8081 (1/4) tap 3: pos=-30.9719 gap=1.0281 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.7800/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.6794 spread=0.7800mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=227.077500 probe at 65.996,275.995 is z=227.070000 Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 65.996,275.995 is z=227.062500 Tap OK (diff=0.0075mm, stable 4/5) probe at 65.996,275.995 is z=227.085000 Tap drift (diff=0.0225mm) — reset probe at 65.996,275.995 is z=227.080000 Tap OK (diff=0.0050mm, stable 2/5) probe at 65.996,275.995 is z=227.082500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0050mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=227.0800 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 06:30:39 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8725, 385.9100, 385.9025, 385.8425, 385.9000, 385.9025, 385.8975, 385.8975, 385.9025, 385.9025, 385.8950, 385.9025, 385.9000, 385.9025, 385.9000
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=395.747500 probe at 65.999,275.995 is z=398.495000 Tap rejete (vibration chassis, z=398.4950 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 65.999,275.995 is z=233.270000 probe at 65.999,275.995 is z=133.755000 Tap drift (diff=99.5150mm) — reset probe at 65.999,275.995 is z=136.380000 Tap drift (diff=2.6250mm) — reset probe at 65.999,275.995 is z=71.735000 Tap drift (diff=64.6450mm) — reset probe at 65.999,275.995 is z=0.785000 Tap drift (diff=70.9500mm) — reset probe at 65.999,275.995 is z=0.797500 Tap drift (diff=0.0125mm) — reset probe at 65.999,275.995 is z=3.422500 probe at 65.999,275.995 is z=0.827500 Tap drift (diff=2.5950mm) — reset probe at 65.999,275.995 is z=3.097500 Tap drift (diff=2.2700mm) — reset probe at 65.999,275.995 is z=5.867500 Tap drift (diff=2.7700mm) — reset probe at 65.999,275.995 is z=7.580000 Tap drift (diff=1.7125mm) — reset probe at 65.999,275.995 is z=0.865000 Tap drift (diff=6.7150mm) — reset probe at 65.999,275.995 is z=0.880000 Tap drift (diff=0.0150mm) — reset probe at 65.999,275.995 is z=0.870000 Tap OK (diff=0.0100mm, stable 2/5) Tap drift (diff=0.0100mm) — reset probe at 65.999,275.995 is z=0.872500 Tap OK (diff=0.0075mm, stable 2/5) probe at 65.999,275.995 is z=0.875000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0050mm, stable 4/5) Tap OK (diff=0.0075mm, stable 5/5) VALIDATED: trigger_z=0.8725 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0)
Screws tilt PASS 06:31:06
probe: at 67.000,271.004 bed will contact at z=1.390000 probe: at 67.000,271.004 bed will contact at z=1.412500 probe: at 67.000,271.004 bed will contact at z=1.405000 probe: at 267.996,271.004 bed will contact at z=1.317500 probe: at 267.996,271.004 bed will contact at z=1.330000 probe: at 267.996,71.995 bed will contact at z=1.325000 probe: at 267.996,71.995 bed will contact at z=1.322500 probe: at 267.996,71.995 bed will contact at z=1.337500 probe: at 67.000,71.995 bed will contact at z=1.287500 probe: at 67.000,71.995 bed will contact at z=1.300000 probe: at 67.000,71.995 bed will contact at z=1.277500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=1.40500 front right screw : x=285.0, y=241.0, z=1.31750 : adjust CCW 00:10 rear right screw : x=285.0, y=42.0, z=1.32500 : adjust CCW 00:10 rear left screw : x=84.0, y=42.0, z=1.28750 : adjust CCW 00:14

History — 2 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-07-13T06:18:11.734773 PASS 450041000D51353234323830 2026-07-17T06:07:37
2026-07-13T02:39:34.135281 PASS 450041000D51353234323830 2026-07-17T06:39:39