SmartPi 1
SmartPi 2

450045000D51353234323830

PASS Grade A Grade B
Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 02813C788EB7
Start : 2026-06-24T03:01:34.361683 · End : 2026-06-24T03:15:17.222827 · Duration : 822 s
Received (server) : 2026-06-24T03:10:44
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 03:01:34
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=450045000D51353234323830
Home X PASS 03:01:59
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.8019 gap=2.1981 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=255.9481 spread=0.1950mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 03:02:23
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 03:02:29
Part fan PASS 03:02:32
Hotend fan PASS 03:02:38
Hotend heat 220°C PASS 03:02:49
Bed heat 60°C PASS 03:03:23
Cutter (feed+cut) PASS 03:04:56
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=256.3869 gap=1.6131 (1/4) tap 3: pos=255.6069 gap=2.3931 (2/4) tap 4: pos=256.1919 gap=1.8081 (3/4) tap 5: pos=255.8019 gap=2.1981 fenetre=0.7800/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.7800mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 03:05:23
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 150mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 03:07:55
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.2041 gap=1.7959 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=181.577500 probe at 31.003,211.998 is z=177.015000 Tap drift (diff=4.5625mm) — reset probe at 31.003,211.998 is z=176.975000 Tap drift (diff=0.0400mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 31.003,211.998 is z=176.977500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0025mm, stable 4/5) probe at 31.003,211.998 is z=176.937500 Tap drift (diff=0.0375mm) — reset probe at 31.003,211.998 is z=176.972500 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=176.9725 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 03:14:44 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.5075, 255.9000, 255.9000, 255.8975, 255.9025, 255.8975, 255.9000, 255.9050, 255.8975, 255.8975, 255.9000, 255.9025, 255.9250, 255.9050, 255.8950
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=223.887500 probe at 30.994,211.998 is z=220.622500 Tap drift (diff=3.2650mm) — reset probe at 30.994,211.998 is z=0.505000 Tap drift (diff=220.1175mm) — reset Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 30.994,211.998 is z=0.507500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.5075 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.897500 Tap OK (diff=0.0000mm, stable 4/5) probe at 30.994,211.998 is z=255.900000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=255.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap OK (diff=0.0025mm, stable 3/5) VALIDATED: trigger_z=255.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.902500 VALIDATED: trigger_z=255.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap OK (diff=0.0025mm, stable 2/5) probe at 30.994,211.998 is z=255.905000 VALIDATED: trigger_z=255.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.895000 probe at 30.994,211.998 is z=255.932500 Tap drift (diff=0.0325mm) — reset Tap drift (diff=0.0300mm) — reset probe at 30.994,211.998 is z=255.930000 Tap drift (diff=0.0250mm) — reset Tap drift (diff=0.0275mm) — reset Tap OK (diff=0.0050mm, stable 2/5) probe at 30.994,211.998 is z=255.907500 Tap OK (diff=0.0075mm, stable 2/5) probe at 30.994,211.998 is z=255.927500 Tap OK (diff=0.0050mm, stable 3/5) probe at 30.994,211.998 is z=255.925000
Screws tilt PASS 03:15:17
probe: at 32.495,205.497 bed will contact at z=1.930000 probe: at 32.495,205.497 bed will contact at z=1.937500 probe: at 32.495,205.497 bed will contact at z=1.922500 probe: at 206.996,205.497 bed will contact at z=1.205000 probe: at 206.996,205.497 bed will contact at z=1.212500 probe: at 206.996,205.497 bed will contact at z=1.252500 probe: at 206.996,31.995 bed will contact at z=1.775000 probe: at 206.996,31.995 bed will contact at z=1.697500 Probe samples exceed tolerance. Retrying... probe: at 206.996,31.995 bed will contact at z=1.787500 probe: at 206.996,31.995 bed will contact at z=1.772500 probe: at 206.996,31.995 bed will contact at z=1.862500 probe: at 206.996,31.995 bed will contact at z=1.782500 probe: at 206.996,31.995 bed will contact at z=1.795000 probe: at 206.996,31.995 bed will contact at z=1.780000 probe: at 32.495,31.995 bed will contact at z=1.595000 probe: at 32.495,31.995 bed will contact at z=1.620000 probe: at 32.495,31.995 bed will contact at z=1.610000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=1.93000 front right screw : x=224.0, y=175.5, z=1.21250 : adjust CCW 01:26 rear right screw : x=224.0, y=2.0, z=1.78250 : adjust CCW 00:18 rear left screw : x=49.5, y=2.0, z=1.61000 : adjust CCW 00:38