← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

480068000F51353135323934

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 02818836C394
Start : 2026-08-08T08:41:46.025275 · End : 2026-08-08T08:54:04.231862 · Duration : 738 s
Received (server) : 2026-08-10T06:07:22
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 08:41:46
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=480068000F51353135323934
Home X PASS 08:42:11
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 08:42:44
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-18.0091 gap=1.9909 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9999 spread=0.0122mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 08:43:33
Part fan PASS 08:43:35
Hotend fan PASS 08:43:37
Hotend heat 220°C PASS 08:43:37
Bed heat 60°C PASS 08:43:59
Cutter (feed+cut) PASS 08:45:27
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9847 gap=2.0153 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-18.0091 gap=1.9909 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 08:45:42
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 08:48:48
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=457.1797 gap=1.8203 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.1828/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.0426 spread=0.1828mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=446.207500 probe at 49.995,339.999 is z=448.602500 Tap drift (diff=2.3950mm) — reset probe at 49.995,339.999 is z=415.162500 Tap drift (diff=33.4400mm) — reset probe at 49.995,339.999 is z=415.185000 Tap drift (diff=0.0225mm) — reset probe at 49.995,339.999 is z=415.180000 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.995,339.999 is z=415.197500 Tap drift (diff=0.0175mm) — reset probe at 49.995,339.999 is z=415.190000 Tap OK (diff=0.0075mm, stable 2/5) probe at 49.995,339.999 is z=415.192500 Tap OK (diff=0.0025mm, stable 3/5) probe at 49.995,339.999 is z=415.202500 Tap drift (diff=0.0100mm) — reset probe at 49.995,339.999 is z=415.187500 Tap drift (diff=0.0150mm) — reset probe at 49.995,339.999 is z=415.200000 Tap OK (diff=0.0075mm, stable 3/5)
Z tap repeatability PASS 08:53:23 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1725, 486.0925, 486.1125, 486.1050, 486.1025, 486.1025, 486.1000, 486.1000, 486.1100, 486.0975, 486.0975, 486.1025, 486.1000, 486.1000, 486.1000
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=457.025000 probe at 49.998,339.999 is z=388.047500 Tap drift (diff=68.9775mm) — reset probe at 49.998,339.999 is z=390.420000 Tap drift (diff=2.3725mm) — reset probe at 49.998,339.999 is z=1.152500 Tap drift (diff=389.2675mm) — reset probe at 49.998,339.999 is z=1.165000 Tap drift (diff=0.0125mm) — reset probe at 49.998,339.999 is z=1.170000 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.998,339.999 is z=1.175000 Tap OK (diff=0.0050mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 49.998,339.999 is z=1.172500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=1.1725 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=486.085000 probe at 49.998,339.999 is z=486.087500 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.998,339.999 is z=486.092500 probe at 49.998,339.999 is z=486.095000 Tap OK (diff=0.0025mm, stable 4/5) VALIDATED: trigger_z=486.0925 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.110000 Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,339.999 is z=486.115000 Tap OK (diff=0.0050mm, stable 4/5) probe at 49.998,339.999 is z=486.112500 VALIDATED: trigger_z=486.1125 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.102500 probe at 49.998,339.999 is z=486.105000 Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0025mm, stable 3/5)
Screws tilt PASS 08:54:04
probe: at 54.997,328.001 bed will contact at z=0.627500 probe: at 54.997,328.001 bed will contact at z=0.632500 probe: at 380.001,328.001 bed will contact at z=0.725000 probe: at 380.001,328.001 bed will contact at z=0.737500 probe: at 380.001,328.001 bed will contact at z=0.750000 probe: at 380.001,101.996 bed will contact at z=0.755000 probe: at 380.001,101.996 bed will contact at z=0.767500 probe: at 54.997,101.996 bed will contact at z=0.595000 probe: at 54.997,101.996 bed will contact at z=0.597500 probe: at 217.505,214.498 bed will contact at z=0.735000 probe: at 217.505,214.498 bed will contact at z=0.725000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=0.62750 front right screw : x=397.0, y=298.0, z=0.73750 : adjust CW 00:13 rear right screw : x=397.0, y=72.0, z=0.75500 : adjust CW 00:15 rear left screw : x=72.0, y=72.0, z=0.59500 : adjust CCW 00:04 middle : x=234.5, y=184.5, z=0.72500 : adjust CW 00:12