← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

490025000F51353135323934

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 0281AE52CB5F
Start : 2026-08-12T07:43:09.368606 · End : 2026-08-12T08:03:30.474945 · Duration : 1221 s
Received (server) : 2026-08-13T02:18:45
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 07:43:09
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=490025000F51353135323934
Home X PASS 07:43:35
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=457.0091 gap=1.9909 (3/4) tap 5: pos=456.9847 gap=2.0153 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 07:44:10
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 07:45:06
Part fan PASS 07:45:17
Hotend fan PASS 07:45:24
Hotend heat 220°C PASS 07:45:24
Bed heat 60°C PASS 07:45:24
Cutter (feed+cut) PASS 07:47:45
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=457.1797 gap=1.8203 (3/4) tap 5: pos=456.8141 gap=2.1859 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 07:47:59
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 07:51:54
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=457.1797 gap=1.8203 (3/4) tap 5: pos=456.8141 gap=2.1859 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=495.787500 probe at 49.995,339.999 is z=465.287500 Tap drift (diff=30.5000mm) — reset probe at 49.995,339.999 is z=468.047500 Tap drift (diff=2.7600mm) — reset probe at 49.995,339.999 is z=470.815000 Tap drift (diff=2.7675mm) — reset probe at 49.995,339.999 is z=473.605000 Tap drift (diff=2.7900mm) — reset probe at 49.995,339.999 is z=476.365000 probe at 49.995,339.999 is z=479.155000 probe at 49.995,339.999 is z=481.935000 Tap drift (diff=2.7800mm) — reset probe at 49.995,339.999 is z=484.692500 Tap drift (diff=2.7575mm) — reset Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) probe at 49.995,339.999 is z=487.450000 probe at 49.995,339.999 is z=490.215000 Tap drift (diff=2.7650mm) — reset probe at 49.995,339.999 is z=492.995000 probe at 49.995,339.999 is z=495.765000
Z tap repeatability PASS 08:02:53 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0625, 486.1075, 486.1075, 486.1050, 486.1075, 486.1025, 486.0925, 486.1050, 486.1025, 486.1000, 486.1025, 486.0975, 486.1025, 486.1075, 486.0950
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=495.630000 probe at 49.998,339.999 is z=498.305000 Tap rejete (vibration chassis, z=498.3050 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 49.998,339.999 is z=498.075000 Tap rejete (vibration chassis, z=498.0750 > max-z_hop) -> pas de remontee, on poursuit la descente (2) probe at 49.998,339.999 is z=497.870000 Tap rejete (vibration chassis, z=497.8700 > max-z_hop) -> pas de remontee, on poursuit la descente (3) probe at 49.998,339.999 is z=368.465000 probe at 49.998,339.999 is z=201.382500 Tap drift (diff=167.0825mm) — reset probe at 49.998,339.999 is z=204.155000 Tap drift (diff=2.7725mm) — reset probe at 49.998,339.999 is z=206.955000 Tap drift (diff=2.8000mm) — reset probe at 49.998,339.999 is z=209.880000 Tap drift (diff=2.9250mm) — reset probe at 49.998,339.999 is z=212.795000 Tap drift (diff=2.9150mm) — reset probe at 49.998,339.999 is z=215.582500 Tap drift (diff=2.7875mm) — reset Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) probe at 49.998,339.999 is z=218.352500 Tap drift (diff=2.7700mm) — reset probe at 49.998,339.999 is z=221.147500 Tap drift (diff=2.7950mm) — reset probe at 49.998,339.999 is z=223.915000 Tap drift (diff=2.7675mm) — reset probe at 49.998,339.999 is z=226.712500 Tap drift (diff=2.7975mm) — reset probe at 49.998,339.999 is z=229.510000 probe at 49.998,339.999 is z=232.305000 probe at 49.998,339.999 is z=235.072500 probe at 49.998,339.999 is z=237.840000 probe at 49.998,339.999 is z=240.632500 Tap drift (diff=2.7925mm) — reset probe at 49.998,339.999 is z=243.425000 probe at 49.998,339.999 is z=246.195000 probe at 49.998,339.999 is z=248.987500
Screws tilt PASS 08:03:30
probe: at 54.997,328.001 bed will contact at z=2.555000 probe: at 54.997,328.001 bed will contact at z=2.552500 probe: at 54.997,328.001 bed will contact at z=2.557500 probe: at 380.001,328.001 bed will contact at z=2.470000 probe: at 380.001,328.001 bed will contact at z=2.455000 probe: at 380.001,101.996 bed will contact at z=2.460000 probe: at 380.001,101.996 bed will contact at z=2.455000 probe: at 380.001,101.996 bed will contact at z=2.462500 probe: at 54.997,101.996 bed will contact at z=2.595000 probe: at 54.997,101.996 bed will contact at z=2.597500 probe: at 54.997,101.996 bed will contact at z=2.592500 probe: at 217.505,214.498 bed will contact at z=2.550000 probe: at 217.505,214.498 bed will contact at z=2.555000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=2.55500 front right screw : x=397.0, y=298.0, z=2.47000 : adjust CCW 00:10 rear right screw : x=397.0, y=72.0, z=2.46000 : adjust CCW 00:11 rear left screw : x=72.0, y=72.0, z=2.59500 : adjust CW 00:05 middle : x=234.5, y=184.5, z=2.55000 : adjust CCW 00:01