| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 07:43:09 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=490025000F51353135323934
|
| Home X | PASS | 07:43:35 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.5941 gap=1.4059 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=457.0091 gap=1.9909 (3/4)
tap 5: pos=456.9847 gap=2.0153 fenetre=0.0244/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 07:44:10 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
|
| Motherboard fan | PASS | 07:45:06 | |
| Part fan | PASS | 07:45:17 | |
| Hotend fan | PASS | 07:45:24 | |
| Hotend heat 220°C | PASS | 07:45:24 | |
| Bed heat 60°C | PASS | 07:45:24 | |
| Cutter (feed+cut) | PASS | 07:47:45 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=457.1797 gap=1.8203 (3/4)
tap 5: pos=456.8141 gap=2.1859 fenetre=0.3656/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 07:47:59 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 07:51:54 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=457.1797 gap=1.8203 (3/4)
tap 5: pos=456.8141 gap=2.1859 fenetre=0.3656/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,339.999 is z=495.787500
probe at 49.995,339.999 is z=465.287500
Tap drift (diff=30.5000mm) — reset
probe at 49.995,339.999 is z=468.047500
Tap drift (diff=2.7600mm) — reset
probe at 49.995,339.999 is z=470.815000
Tap drift (diff=2.7675mm) — reset
probe at 49.995,339.999 is z=473.605000
Tap drift (diff=2.7900mm) — reset
probe at 49.995,339.999 is z=476.365000
probe at 49.995,339.999 is z=479.155000
probe at 49.995,339.999 is z=481.935000
Tap drift (diff=2.7800mm) — reset
probe at 49.995,339.999 is z=484.692500
Tap drift (diff=2.7575mm) — reset
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
probe at 49.995,339.999 is z=487.450000
probe at 49.995,339.999 is z=490.215000
Tap drift (diff=2.7650mm) — reset
probe at 49.995,339.999 is z=492.995000
probe at 49.995,339.999 is z=495.765000
|
| Z tap repeatability | PASS | 08:02:53 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0625, 486.1075, 486.1075, 486.1050, 486.1075, 486.1025, 486.0925, 486.1050, 486.1025, 486.1000, 486.1025, 486.0975, 486.1025, 486.1075, 486.0950
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,339.999 is z=495.630000
probe at 49.998,339.999 is z=498.305000
Tap rejete (vibration chassis, z=498.3050 > max-z_hop) -> pas de remontee, on poursuit la descente (1)
probe at 49.998,339.999 is z=498.075000
Tap rejete (vibration chassis, z=498.0750 > max-z_hop) -> pas de remontee, on poursuit la descente (2)
probe at 49.998,339.999 is z=497.870000
Tap rejete (vibration chassis, z=497.8700 > max-z_hop) -> pas de remontee, on poursuit la descente (3)
probe at 49.998,339.999 is z=368.465000
probe at 49.998,339.999 is z=201.382500
Tap drift (diff=167.0825mm) — reset
probe at 49.998,339.999 is z=204.155000
Tap drift (diff=2.7725mm) — reset
probe at 49.998,339.999 is z=206.955000
Tap drift (diff=2.8000mm) — reset
probe at 49.998,339.999 is z=209.880000
Tap drift (diff=2.9250mm) — reset
probe at 49.998,339.999 is z=212.795000
Tap drift (diff=2.9150mm) — reset
probe at 49.998,339.999 is z=215.582500
Tap drift (diff=2.7875mm) — reset
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
probe at 49.998,339.999 is z=218.352500
Tap drift (diff=2.7700mm) — reset
probe at 49.998,339.999 is z=221.147500
Tap drift (diff=2.7950mm) — reset
probe at 49.998,339.999 is z=223.915000
Tap drift (diff=2.7675mm) — reset
probe at 49.998,339.999 is z=226.712500
Tap drift (diff=2.7975mm) — reset
probe at 49.998,339.999 is z=229.510000
probe at 49.998,339.999 is z=232.305000
probe at 49.998,339.999 is z=235.072500
probe at 49.998,339.999 is z=237.840000
probe at 49.998,339.999 is z=240.632500
Tap drift (diff=2.7925mm) — reset
probe at 49.998,339.999 is z=243.425000
probe at 49.998,339.999 is z=246.195000
probe at 49.998,339.999 is z=248.987500
|
| Screws tilt | PASS | 08:03:30 |
probe: at 54.997,328.001 bed will contact at z=2.555000
probe: at 54.997,328.001 bed will contact at z=2.552500
probe: at 54.997,328.001 bed will contact at z=2.557500
probe: at 380.001,328.001 bed will contact at z=2.470000
probe: at 380.001,328.001 bed will contact at z=2.455000
probe: at 380.001,101.996 bed will contact at z=2.460000
probe: at 380.001,101.996 bed will contact at z=2.455000
probe: at 380.001,101.996 bed will contact at z=2.462500
probe: at 54.997,101.996 bed will contact at z=2.595000
probe: at 54.997,101.996 bed will contact at z=2.597500
probe: at 54.997,101.996 bed will contact at z=2.592500
probe: at 217.505,214.498 bed will contact at z=2.550000
probe: at 217.505,214.498 bed will contact at z=2.555000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=298.0, z=2.55500
front right screw : x=397.0, y=298.0, z=2.47000 : adjust CCW 00:10
rear right screw : x=397.0, y=72.0, z=2.46000 : adjust CCW 00:11
rear left screw : x=72.0, y=72.0, z=2.59500 : adjust CW 00:05
middle : x=234.5, y=184.5, z=2.55000 : adjust CCW 00:01
|