← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

490027000F51353135323934

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 0281605119E6
Start : 2026-07-15T06:41:19.764784 · End : 2026-07-15T06:53:45.395226 · Duration : 745 s
Received (server) : 2026-07-15T06:53:46
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 06:41:19
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=490027000F51353135323934
Home X PASS 06:41:46
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 06:42:21
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 06:42:26
Part fan PASS 06:42:28
Hotend fan PASS 06:42:34
Hotend heat 220°C PASS 06:42:43
Bed heat 60°C PASS 06:42:48
Cutter (feed+cut) PASS 06:44:26
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=357.1797 gap=1.8203 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.8141 gap=2.1859 (3/4) tap 5: pos=357.1797 gap=1.8203 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.0426 spread=0.3656mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 06:44:41
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 06:47:28
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=357.1797 gap=1.8203 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=357.7769 gap=1.2231 (3/4) tap 5: pos=357.5941 gap=1.4059 fenetre=0.7800/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.3869 spread=0.7800mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=395.687500 probe at 65.996,275.995 is z=314.352500 Tap drift (diff=81.3350mm) — reset probe at 65.996,275.995 is z=314.417500 Tap drift (diff=0.0650mm) — reset probe at 65.996,275.995 is z=314.412500 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0050mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 65.996,275.995 is z=314.420000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=314.4200 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 06:53:04 OK: 3 taps convergents spread=0.0025mm (tol=0.0500) sur 15 taps | taps=0.8525, 385.9300, 385.8850, 385.9125, 385.8975, 385.9100, 385.9025, 385.9025, 385.8950, 385.9000, 385.9100, 385.8875, 385.8950, 385.9050, 385.9000
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=96.527500 probe at 65.999,275.995 is z=0.797500 Tap drift (diff=95.7300mm) — reset probe at 65.999,275.995 is z=0.845000 Tap drift (diff=0.0475mm) — reset probe at 65.999,275.995 is z=0.847500 Tap OK (diff=0.0025mm, stable 2/5) probe at 65.999,275.995 is z=0.850000 Tap OK (diff=0.0025mm, stable 3/5) probe at 65.999,275.995 is z=0.855000 Tap OK (diff=0.0050mm, stable 4/5) probe at 65.999,275.995 is z=0.852500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=0.8525 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=385.957500 probe at 65.999,275.995 is z=385.897500 Tap drift (diff=0.0600mm) — reset probe at 65.999,275.995 is z=385.912500 Tap drift (diff=0.0150mm) — reset probe at 65.999,275.995 is z=385.915000 probe at 65.999,275.995 is z=385.922500 Tap OK (diff=0.0075mm, stable 3/5) Tap OK (diff=0.0075mm, stable 4/5) probe at 65.999,275.995 is z=385.925000 Tap drift (diff=0.0100mm) — reset Tap OK (diff=0.0100mm, stable 3/5) probe at 65.999,275.995 is z=385.927500 probe at 65.999,275.995 is z=385.930000 Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=385.9300 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.832500 probe at 65.999,275.995 is z=385.877500 Tap drift (diff=0.0450mm) — reset probe at 65.999,275.995 is z=385.892500
Screws tilt PASS 06:53:45
probe: at 67.000,271.004 bed will contact at z=1.180000 probe: at 67.000,271.004 bed will contact at z=1.245000 Probe samples exceed tolerance. Retrying... probe: at 67.000,271.004 bed will contact at z=1.252500 probe: at 67.000,271.004 bed will contact at z=1.285000 probe: at 67.000,271.004 bed will contact at z=1.275000 probe: at 267.996,271.004 bed will contact at z=0.977500 probe: at 267.996,271.004 bed will contact at z=1.085000 probe: at 267.996,271.004 bed will contact at z=1.097500 probe: at 267.996,271.004 bed will contact at z=1.095000 probe: at 267.996,271.004 bed will contact at z=1.092500 probe: at 267.996,71.995 bed will contact at z=1.102500 probe: at 267.996,71.995 bed will contact at z=1.190000 probe: at 267.996,71.995 bed will contact at z=1.207500 probe: at 267.996,71.995 bed will contact at z=1.197500 probe: at 67.000,71.995 bed will contact at z=0.822500 probe: at 67.000,71.995 bed will contact at z=0.932500 probe: at 67.000,71.995 bed will contact at z=0.942500 probe: at 67.000,71.995 bed will contact at z=0.955000 probe: at 67.000,71.995 bed will contact at z=0.930000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=1.27500 front right screw : x=285.0, y=241.0, z=1.09500 : adjust CCW 00:22 rear right screw : x=285.0, y=42.0, z=1.19750 : adjust CCW 00:09 rear left screw : x=84.0, y=42.0, z=0.94250 : adjust CCW 00:40

History — 3 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-07-15T06:41:19.764784 PASS 490027000F51353135323934 2026-07-15T06:53:46
2026-07-15T05:46:08.571504 FAIL 490027000F51353135323934 2026-07-15T06:00:13
2026-07-15T05:16:01.249026 FAIL 490027000F51353135323934 2026-07-15T05:31:30