49004B000F51353135323934

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 028133CB7186
Start : 2026-07-25T06:08:12.502393 · End : 2026-07-25T06:20:10.597072 · Duration : 718 s
Received (server) : 2026-07-25T06:34:20
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 06:08:12
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=49004B000F51353135323934
Home X PASS 06:08:38
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 06:09:11
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-30.5941 gap=1.4059 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-30.1797 gap=1.8203 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.1919 spread=0.5972mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 06:09:17
Part fan PASS 06:09:19
Hotend fan PASS 06:09:22
Hotend heat 220°C PASS 06:09:25
Bed heat 60°C PASS 06:09:39
Cutter (feed+cut) PASS 06:11:07
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-30.1797 gap=1.8203 fenetre=0.1828/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.0426 spread=0.1828mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 06:11:18
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 06:14:23
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-30.5941 gap=1.4059 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.1462 spread=0.5972mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=355.957500 probe at 65.996,275.995 is z=355.995000 Tap drift (diff=0.0375mm) — reset probe at 65.996,275.995 is z=356.032500 probe at 65.996,275.995 is z=356.040000 Tap OK (diff=0.0075mm, stable 2/5) probe at 65.996,275.995 is z=356.067500 Tap drift (diff=0.0275mm) — reset probe at 65.996,275.995 is z=356.075000 probe at 65.996,275.995 is z=356.100000 Tap drift (diff=0.0250mm) — reset probe at 65.996,275.995 is z=356.112500 Tap drift (diff=0.0125mm) — reset probe at 65.996,275.995 is z=356.117500 Tap OK (diff=0.0050mm, stable 2/5) probe at 65.996,275.995 is z=356.135000 Tap drift (diff=0.0175mm) — reset probe at 65.996,275.995 is z=356.145000 Tap drift (diff=0.0100mm) — reset probe at 65.996,275.995 is z=356.152500 Tap OK (diff=0.0000mm, stable 3/5)
Z tap repeatability PASS 06:19:38 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=60.1150, 385.9325, 385.9100, 385.9225, 385.9150, 385.9025, 385.9300, 385.9050, 385.9025, 385.9050, 385.9250, 385.9050, 385.9025, 385.9050, 385.9275
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=395.710000 probe at 65.999,275.995 is z=398.182500 Tap rejete (vibration chassis, z=398.1825 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 65.999,275.995 is z=398.037500 Tap rejete (vibration chassis, z=398.0375 > max-z_hop) -> pas de remontee, on poursuit la descente (2) probe at 65.999,275.995 is z=397.502500 Tap rejete (vibration chassis, z=397.5025 > max-z_hop) -> pas de remontee, on poursuit la descente (3) probe at 65.999,275.995 is z=397.182500 Tap rejete (vibration chassis, z=397.1825 > max-z_hop) -> pas de remontee, on poursuit la descente (4) probe at 65.999,275.995 is z=392.790000 probe at 65.999,275.995 is z=395.502500 Tap drift (diff=2.7125mm) — reset probe at 65.999,275.995 is z=350.107500 Tap drift (diff=45.3950mm) — reset probe at 65.999,275.995 is z=352.772500 Tap drift (diff=2.6650mm) — reset probe at 65.999,275.995 is z=329.915000 Tap drift (diff=22.8575mm) — reset Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) probe at 65.999,275.995 is z=332.630000 Tap drift (diff=2.7150mm) — reset probe at 65.999,275.995 is z=334.947500 Tap drift (diff=2.3175mm) — reset probe at 65.999,275.995 is z=337.650000 Tap drift (diff=2.7025mm) — reset probe at 65.999,275.995 is z=340.307500 Tap drift (diff=2.6575mm) — reset probe at 65.999,275.995 is z=184.225000 Tap drift (diff=156.0825mm) — reset probe at 65.999,275.995 is z=186.800000 Tap drift (diff=2.5750mm) — reset probe at 65.999,275.995 is z=60.030000 Tap drift (diff=126.7700mm) — reset probe at 65.999,275.995 is z=62.617500 Tap drift (diff=2.5875mm) — reset probe at 65.999,275.995 is z=65.400000 Tap drift (diff=2.7825mm) — reset probe at 65.999,275.995 is z=60.072500
Screws tilt PASS 06:20:10
probe: at 67.000,271.004 bed will contact at z=2.285000 probe: at 67.000,271.004 bed will contact at z=2.367500 Probe samples exceed tolerance. Retrying... probe: at 67.000,271.004 bed will contact at z=2.357500 probe: at 67.000,271.004 bed will contact at z=2.375000 probe: at 267.996,271.004 bed will contact at z=2.187500 probe: at 267.996,271.004 bed will contact at z=2.207500 probe: at 267.996,271.004 bed will contact at z=2.212500 probe: at 267.996,71.995 bed will contact at z=2.067500 probe: at 267.996,71.995 bed will contact at z=2.095000 probe: at 267.996,71.995 bed will contact at z=2.097500 probe: at 67.000,71.995 bed will contact at z=2.230000 probe: at 67.000,71.995 bed will contact at z=2.265000 probe: at 67.000,71.995 bed will contact at z=2.275000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=2.36750 front right screw : x=285.0, y=241.0, z=2.20750 : adjust CCW 00:19 rear right screw : x=285.0, y=42.0, z=2.09500 : adjust CCW 00:33 rear left screw : x=84.0, y=42.0, z=2.26500 : adjust CCW 00:12