| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 01:07:47 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=490068000F51353135323934
|
| Home X | PASS | 01:08:09 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=256.5697 gap=1.4303 (chauffe, ignore)
tap 2: pos=255.9969 gap=2.0031 (1/4)
tap 3: pos=255.9969 gap=2.0031 (2/4)
tap 4: pos=255.9969 gap=2.0031 (3/4)
tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
|
| Home Y | PASS | 01:08:39 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.5819 gap=1.4181 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
|
| Motherboard fan | PASS | 01:08:57 | |
| Part fan | PASS | 01:08:59 | |
| Hotend fan | PASS | 01:09:01 | |
| Hotend heat 220°C | PASS | 01:09:11 | |
| Bed heat 60°C | PASS | 01:09:11 | |
| Cutter (feed+cut) | PASS | 01:11:56 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=256.5575 gap=1.4425 (chauffe, ignore)
tap 2: pos=255.9969 gap=2.0031 (1/4)
tap 3: pos=255.9969 gap=2.0031 (2/4)
tap 4: pos=255.9969 gap=2.0031 (3/4)
tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.9719 gap=1.0281 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 01:12:10 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 01:14:40 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=256.4112 gap=1.5888 (chauffe, ignore)
tap 2: pos=255.9969 gap=2.0031 (1/4)
tap 3: pos=255.9969 gap=2.0031 (2/4)
tap 4: pos=255.9969 gap=2.0031 (3/4)
tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.9719 gap=1.0281 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Moving to tap point X=31.0 Y=212.0...
Probing with pressure switch...
probe at 31.003,211.998 is z=265.490000
probe at 31.003,211.998 is z=232.292500
Tap drift (diff=33.1975mm) — reset
probe at 31.003,211.998 is z=120.380000
Tap drift (diff=111.9125mm) — reset
probe at 31.003,211.998 is z=123.175000
Tap drift (diff=2.7950mm) — reset
probe at 31.003,211.998 is z=120.377500
Tap drift (diff=2.7975mm) — reset
Tap OK (diff=0.0025mm, stable 2/5)
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
probe at 31.003,211.998 is z=120.375000
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=120.3750 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 01:18:52 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.7500, 255.9025, 255.9000, 255.8925, 255.9000, 255.8975, 255.9000, 255.9000, 255.9025, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000
Moving to tap point X=31.0 Y=212.0...
Probing with pressure switch...
probe at 30.994,211.998 is z=265.542500
probe at 30.994,211.998 is z=267.835000
Tap rejete (vibration chassis, z=267.8350 > max-z_hop) -> pas de remontee, on poursuit la descente (1)
probe at 30.994,211.998 is z=52.415000
probe at 30.994,211.998 is z=0.710000
Tap drift (diff=51.7050mm) — reset
probe at 30.994,211.998 is z=0.745000
Tap drift (diff=0.0350mm) — reset
probe at 30.994,211.998 is z=0.747500
Tap OK (diff=0.0025mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
probe at 30.994,211.998 is z=0.750000
Tap OK (diff=0.0025mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=0.7500 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0)
Z calibration complete!
probe at 30.994,211.998 is z=255.892500
probe at 30.994,211.998 is z=255.900000
Tap OK (diff=0.0075mm, stable 2/5)
probe at 30.994,211.998 is z=255.902500
VALIDATED: trigger_z=255.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Tap OK (diff=0.0000mm, stable 4/5)
probe at 30.994,211.998 is z=255.937500
Tap drift (diff=0.0375mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
VALIDATED: trigger_z=255.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 30.994,211.998 is z=255.897500
probe at 30.994,211.998 is z=255.907500
Tap drift (diff=0.0100mm) — reset
probe at 30.994,211.998 is z=256.840000
Tap drift (diff=0.9325mm) — reset
probe at 30.994,211.998 is z=259.130000
Tap drift (diff=2.2900mm) — reset
Tap drift (diff=3.2275mm) — reset
Tap OK (diff=0.0050mm, stable 2/5)
Tap OK (diff=0.0050mm, stable 4/5)
Tap OK (diff=0.0100mm, stable 5/5)
|
| Screws tilt | PASS | 01:19:17 |
probe: at 32.495,205.497 bed will contact at z=0.712500
probe: at 32.495,205.497 bed will contact at z=0.717500
probe: at 32.495,205.497 bed will contact at z=0.705000
probe: at 206.996,205.497 bed will contact at z=3.310000
probe: at 206.996,205.497 bed will contact at z=3.317500
probe: at 206.996,205.497 bed will contact at z=3.332500
probe: at 206.996,31.995 bed will contact at z=4.590000
probe: at 206.996,31.995 bed will contact at z=4.605000
probe: at 206.996,31.995 bed will contact at z=4.575000
probe: at 32.495,31.995 bed will contact at z=2.237500
probe: at 32.495,31.995 bed will contact at z=2.245000
probe: at 32.495,31.995 bed will contact at z=2.240000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=49.5, y=175.5, z=0.71250
front right screw : x=224.0, y=175.5, z=3.31750 : adjust CW 05:13
rear right screw : x=224.0, y=2.0, z=4.59000 : adjust CW 07:45
rear left screw : x=49.5, y=2.0, z=2.24000 : adjust CW 03:03
|
| QC date | Result | QC pad (MAC) | Received (server) |
|---|---|---|---|
| 2026-07-01T01:07:47.451534 | PASS | 490068000F51353135323934 | 2026-07-01T01:35:53 |
| 2026-07-01T00:36:06.327359 | FAIL | 490068000F51353135323934 | 2026-07-01T00:36:28 |
| 2026-06-30T09:06:24.153036 | PARTIAL | 490068000F51353135323934 | 2026-06-30T09:05:41 |
| 2026-06-30T05:25:10.869065 | PARTIAL | 490068000F51353135323934 | 2026-06-30T05:24:46 |
| 2026-06-30T05:14:37.947399 | FAIL | 490068000F51353135323934 | 2026-06-30T05:15:08 |
| 2026-06-30T05:04:29.757573 | PARTIAL | 490068000F51353135323934 | 2026-06-30T05:03:32 |