| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 04:31:34 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=4A0020000F51353135323934
|
| Home X | PASS | 04:32:00 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.5941 gap=1.4059 (chauffe, ignore)
tap 2: pos=357.0091 gap=1.9909 (1/4)
tap 3: pos=356.9969 gap=2.0031 (2/4)
tap 4: pos=356.9847 gap=2.0153 (3/4)
tap 5: pos=356.9969 gap=2.0031 fenetre=0.0244/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=357.0000
|
| Home Y | PASS | 04:32:33 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore)
tap 2: pos=-30.7769 gap=1.2231 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-30.7769 gap=1.2231 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.7800/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.3869 spread=0.7800mm (tol=0.0500). Zero pose en butee=-30.0000
|
| Motherboard fan | PASS | 04:33:16 | |
| Part fan | PASS | 04:33:19 | |
| Hotend fan | PASS | 04:33:21 | |
| Hotend heat 220°C | PASS | 04:33:21 | |
| Bed heat 60°C | PASS | 04:33:22 | |
| Cutter (feed+cut) | PASS | 04:34:50 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.5941 gap=1.4059 (chauffe, ignore)
tap 2: pos=356.9969 gap=2.0031 (1/4)
tap 3: pos=356.9969 gap=2.0031 (2/4)
tap 4: pos=356.9969 gap=2.0031 (3/4)
tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 04:35:01 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 04:37:54 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.5941 gap=1.4059 (chauffe, ignore)
tap 2: pos=357.0091 gap=1.9909 (1/4)
tap 3: pos=356.9969 gap=2.0031 (2/4)
tap 4: pos=356.9969 gap=2.0031 (3/4)
tap 5: pos=356.9969 gap=2.0031 fenetre=0.0122/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9999 spread=0.0122mm (tol=0.0500). Zero pose en butee=357.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Moving to tap point X=66.0 Y=276.0...
Probing with pressure switch...
probe at 65.996,275.995 is z=306.410000
probe at 65.996,275.995 is z=306.420000
Tap drift (diff=0.0100mm) — reset
probe at 65.996,275.995 is z=306.425000
Tap OK (diff=0.0050mm, stable 2/5)
probe at 65.996,275.995 is z=306.722500
Tap drift (diff=0.2975mm) — reset
probe at 65.996,275.995 is z=306.442500
Tap drift (diff=0.2800mm) — reset
probe at 65.996,275.995 is z=306.430000
Tap drift (diff=0.0125mm) — reset
probe at 65.996,275.995 is z=306.422500
Tap OK (diff=0.0075mm, stable 2/5)
probe at 65.996,275.995 is z=306.427500
Tap OK (diff=0.0050mm, stable 3/5)
Tap OK (diff=0.0025mm, stable 4/5)
probe at 65.996,275.995 is z=306.432500
Tap OK (diff=0.0075mm, stable 5/5)
VALIDATED: trigger_z=306.4325 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 04:42:47 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9075, 385.9000, 385.8925, 385.9125, 385.9025, 385.9075, 385.9025, 385.8900, 385.8975, 385.8975, 385.9000, 385.9025, 385.9000, 385.9000, 385.9025
Moving to tap point X=66.0 Y=276.0...
Probing with pressure switch...
probe at 65.999,275.995 is z=355.262500
probe at 65.999,275.995 is z=358.177500
Tap drift (diff=2.9150mm) — reset
probe at 65.999,275.995 is z=188.945000
Tap drift (diff=169.2325mm) — reset
probe at 65.999,275.995 is z=178.912500
Tap drift (diff=10.0325mm) — reset
probe at 65.999,275.995 is z=0.885000
Tap drift (diff=178.0275mm) — reset
probe at 65.999,275.995 is z=0.905000
Tap drift (diff=0.0200mm) — reset
probe at 65.999,275.995 is z=0.910000
Tap OK (diff=0.0050mm, stable 2/5)
probe at 65.999,275.995 is z=0.900000
Tap OK (diff=0.0100mm, stable 3/5)
probe at 65.999,275.995 is z=0.907500
Tap OK (diff=0.0075mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=0.9075 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0)
Z calibration complete!
probe at 65.999,275.995 is z=385.887500
probe at 65.999,275.995 is z=385.902500
Tap drift (diff=0.0150mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
probe at 65.999,275.995 is z=385.905000
Tap OK (diff=0.0025mm, stable 4/5)
probe at 65.999,275.995 is z=385.900000
Tap OK (diff=0.0050mm, stable 5/5)
VALIDATED: trigger_z=385.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Tap OK (diff=0.0025mm, stable 2/5)
probe at 65.999,275.995 is z=385.895000
probe at 65.999,275.995 is z=385.892500
Tap OK (diff=0.0100mm, stable 5/5)
VALIDATED: trigger_z=385.8925 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 65.999,275.995 is z=391.070000
Tap drift (diff=5.1750mm) — reset
|
| Screws tilt | PASS | 04:43:45 |
probe: at 67.000,271.004 bed will contact at z=1.692500
probe: at 67.000,271.004 bed will contact at z=1.640000
Probe samples exceed tolerance. Retrying...
probe: at 67.000,271.004 bed will contact at z=1.645000
probe: at 67.000,271.004 bed will contact at z=1.702500
probe: at 67.000,271.004 bed will contact at z=1.722500
probe: at 67.000,271.004 bed will contact at z=1.682500
probe: at 67.000,271.004 bed will contact at z=1.650000
probe: at 67.000,271.004 bed will contact at z=1.752500
probe: at 67.000,271.004 bed will contact at z=1.732500
probe: at 67.000,271.004 bed will contact at z=1.635000
probe: at 67.000,271.004 bed will contact at z=1.675000
probe: at 67.000,271.004 bed will contact at z=1.655000
probe: at 67.000,271.004 bed will contact at z=1.707500
probe: at 67.000,271.004 bed will contact at z=1.622500
probe: at 67.000,271.004 bed will contact at z=1.715000
probe: at 67.000,271.004 bed will contact at z=1.680000
probe: at 67.000,271.004 bed will contact at z=1.667500
probe: at 67.000,271.004 bed will contact at z=1.625000
probe: at 67.000,271.004 bed will contact at z=1.660000
probe: at 67.000,271.004 bed will contact at z=1.665000
probe: at 267.996,271.004 bed will contact at z=1.740000
probe: at 267.996,71.995 bed will contact at z=1.620000
probe: at 267.996,71.995 bed will contact at z=1.615000
probe: at 267.996,71.995 bed will contact at z=1.617500
probe: at 67.000,71.995 bed will contact at z=1.660000
probe: at 67.000,71.995 bed will contact at z=1.615000
probe: at 67.000,71.995 bed will contact at z=1.667500
probe: at 67.000,71.995 bed will contact at z=1.637500
probe: at 67.000,71.995 bed will contact at z=1.662500
probe: at 67.000,71.995 bed will contact at z=1.632500
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=84.0, y=241.0, z=1.66500
front right screw : x=285.0, y=241.0, z=1.74000 : adjust CW 00:09
rear right screw : x=285.0, y=42.0, z=1.61750 : adjust CCW 00:06
rear left screw : x=84.0, y=42.0, z=1.63750 : adjust CCW 00:03
|
Moves this report to the trash — you can restore it from /trash.