| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 02:15:51 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=4A0043000F51353135323934
|
| Home X | PASS | 02:16:12 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=256.7769 gap=1.2231 (chauffe, ignore)
tap 2: pos=255.9969 gap=2.0031 (1/4)
tap 3: pos=255.9969 gap=2.0031 (2/4)
tap 4: pos=255.9969 gap=2.0031 (3/4)
tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
|
| Home Y | PASS | 02:16:47 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.3869 gap=1.6131 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
|
| Motherboard fan | PASS | 02:16:54 | |
| Part fan | PASS | 02:17:02 | |
| Hotend fan | PASS | 02:17:07 | |
| Hotend heat 220°C | PASS | 02:17:10 | |
| Bed heat 60°C | PASS | 02:17:31 | |
| Cutter (feed+cut) | PASS | 02:18:51 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=255.9969 gap=2.0031 (1/4)
tap 3: pos=255.9969 gap=2.0031 (2/4)
tap 4: pos=255.9969 gap=2.0031 (3/4)
tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.0091 gap=1.9909 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-30.1919 gap=1.8081 (2/4)
tap 4: pos=-29.8019 gap=2.1981 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.3900/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=-30.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 02:19:02 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 02:21:37 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=255.9969 gap=2.0031 (1/4)
tap 3: pos=255.9969 gap=2.0031 (2/4)
tap 4: pos=255.9969 gap=2.0031 (3/4)
tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Moving to tap point X=31.0 Y=212.0...
Probing with pressure switch...
probe at 31.003,211.998 is z=265.862500
probe at 31.003,211.998 is z=268.617500
Tap rejete (vibration chassis, z=268.6175 > max-z_hop) -> pas de remontee, on poursuit la descente (1)
probe at 31.003,211.998 is z=176.092500
probe at 31.003,211.998 is z=176.102500
Tap OK (diff=0.0100mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
probe at 31.003,211.998 is z=176.100000
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=176.1000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 02:27:02 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9650, 255.9075, 255.9000, 255.9500, 255.8950, 255.9000, 255.9000, 255.9000, 255.8975, 255.8975, 255.9000, 255.8975, 255.8950, 255.8975, 255.8800
Moving to tap point X=31.0 Y=212.0...
Probing with pressure switch...
probe at 30.994,211.998 is z=12.687500
probe at 30.994,211.998 is z=0.932500
Tap drift (diff=11.7550mm) — reset
probe at 30.994,211.998 is z=0.967500
Tap drift (diff=0.0350mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
probe at 30.994,211.998 is z=0.962500
Tap OK (diff=0.0050mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
probe at 30.994,211.998 is z=0.965000
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=0.9650 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0)
Z calibration complete!
probe at 30.994,211.998 is z=255.872500
probe at 30.994,211.998 is z=255.902500
Tap drift (diff=0.0300mm) — reset
probe at 30.994,211.998 is z=258.155000
Tap drift (diff=2.2525mm) — reset
probe at 30.994,211.998 is z=255.880000
Tap drift (diff=2.2750mm) — reset
probe at 30.994,211.998 is z=255.905000
Tap drift (diff=0.0250mm) — reset
probe at 30.994,211.998 is z=255.900000
Tap OK (diff=0.0050mm, stable 2/5)
probe at 30.994,211.998 is z=255.907500
Tap OK (diff=0.0025mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=255.9075 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 30.994,211.998 is z=255.867500
probe at 30.994,211.998 is z=255.895000
Tap drift (diff=0.0275mm) — reset
probe at 30.994,211.998 is z=255.897500
Tap OK (diff=0.0025mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
VALIDATED: trigger_z=255.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 30.994,211.998 is z=265.140000
probe at 30.994,211.998 is z=255.860000
|
| Screws tilt | PASS | 02:27:48 |
probe: at 32.495,205.497 bed will contact at z=1.612500
probe: at 32.495,205.497 bed will contact at z=1.710000
Probe samples exceed tolerance. Retrying...
probe: at 32.495,205.497 bed will contact at z=1.712500
probe: at 32.495,205.497 bed will contact at z=1.715000
probe: at 206.996,205.497 bed will contact at z=4.830000
probe: at 206.996,205.497 bed will contact at z=4.840000
probe: at 206.996,205.497 bed will contact at z=4.962500
probe: at 206.996,205.497 bed will contact at z=4.945000
probe: at 206.996,205.497 bed will contact at z=4.967500
probe: at 206.996,205.497 bed will contact at z=4.890000
probe: at 206.996,205.497 bed will contact at z=4.802500
probe: at 206.996,205.497 bed will contact at z=4.627500
probe: at 206.996,205.497 bed will contact at z=4.905000
probe: at 206.996,205.497 bed will contact at z=4.790000
probe: at 206.996,205.497 bed will contact at z=4.922500
probe: at 206.996,205.497 bed will contact at z=4.940000
probe: at 206.996,205.497 bed will contact at z=4.895000
probe: at 206.996,205.497 bed will contact at z=4.900000
probe: at 206.996,205.497 bed will contact at z=4.860000
probe: at 206.996,31.995 bed will contact at z=5.467500
probe: at 206.996,31.995 bed will contact at z=5.587500
probe: at 206.996,31.995 bed will contact at z=5.590000
probe: at 206.996,31.995 bed will contact at z=5.637500
probe: at 32.495,31.995 bed will contact at z=2.517500
probe: at 32.495,31.995 bed will contact at z=2.535000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=49.5, y=175.5, z=1.71500
front right screw : x=224.0, y=175.5, z=4.89500 : adjust CW 06:22
rear right screw : x=224.0, y=2.0, z=5.59000 : adjust CW 07:45
rear left screw : x=49.5, y=2.0, z=2.53500 : adjust CW 01:38
|