← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

4A0051000F51353135323934

PASS Grade A Grade B
Model : C235 · Batch : 20260618
Heated bed : 110V · 300W · SSR SSR10DA
QC pad (MAC) : 02813C788EB7
Start : 2026-07-10T03:16:29.135058 · End : 2026-07-10T03:27:13.103960 · Duration : 643 s
Received (server) : 2026-07-10T04:30:31
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=300 ssr=SSR10DA lot=20260618 uid=BBA413

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 03:16:29
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=300;ssr=SSR10DA;lot=20260618;uid=BBA413 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4A0051000F51353135323934
Home X PASS 03:16:55
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 03:17:40
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1 rejete: cible atteinte sans buter (gap=0.0653) tap 2 rejete: cible atteinte sans buter (gap=0.0531) YUMI_SENSORLESS_HOME Y: home de base suspect (pas de contact) -> re-home de recuperation 1/2 tap 3 rejete: cible atteinte sans buter (gap=0.0166) tap 4 rejete: cible atteinte sans buter (gap=0.0409) YUMI_SENSORLESS_HOME Y: home de base suspect (pas de contact) -> re-home de recuperation 2/2 tap 5 rejete: cible atteinte sans buter (gap=0.0166) tap 6: pos=-30.9841 gap=1.0159 (chauffe, ignore) tap 7: pos=-30.0091 gap=1.9909 (1/4) tap 8: pos=-29.9969 gap=2.0031 (2/4) tap 9: pos=-29.9969 gap=2.0031 (3/4) tap 10: pos=-29.9969 gap=2.0031 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (5 rejetes) -> moyenne=-29.9999 spread=0.0122mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 03:18:10
Part fan PASS 03:18:12
Hotend fan PASS 03:18:16
Hotend heat 220°C PASS 03:18:16
Bed heat 60°C PASS 03:18:16
Cutter (feed+cut) PASS 03:19:49
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1 rejete: cible atteinte sans buter (gap=0.0531) tap 2 rejete: cible atteinte sans buter (gap=0.0653) YUMI_SENSORLESS_HOME Y: home de base suspect (pas de contact) -> re-home de recuperation 1/2 tap 3 rejete: cible atteinte sans buter (gap=0.6503) tap 4: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 5: pos=-30.0091 gap=1.9909 (1/4) tap 6: pos=-29.9969 gap=2.0031 (2/4) tap 7: pos=-29.9969 gap=2.0031 (3/4) tap 8: pos=-29.9969 gap=2.0031 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (3 rejetes) -> moyenne=-29.9999 spread=0.0122mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 03:20:00
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 03:22:47
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1 rejete: cible atteinte sans buter (gap=0.0531) tap 2 rejete: cible atteinte sans buter (gap=0.0653) YUMI_SENSORLESS_HOME Y: home de base suspect (pas de contact) -> re-home de recuperation 1/2 tap 3 rejete: cible atteinte sans buter (gap=0.0653) tap 4: pos=-30.3869 gap=1.6131 (chauffe, ignore) tap 5: pos=-30.7769 gap=1.2231 (1/4) tap 6: pos=-30.5941 gap=1.4059 (2/4) tap 7: pos=-30.1797 gap=1.8203 (3/4) tap 8: pos=-30.7769 gap=1.2231 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (3 rejetes) -> moyenne=-30.5819 spread=0.5972mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=174.737500 probe at 31.003,211.998 is z=153.430000 Tap drift (diff=21.3075mm) — reset probe at 31.003,211.998 is z=153.422500 Tap OK (diff=0.0075mm, stable 2/5) probe at 31.003,211.998 is z=153.417500 Tap OK (diff=0.0050mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 31.003,211.998 is z=153.420000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=153.4200 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 03:26:48 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9750, 255.9025, 255.8950, 255.8975, 255.9025, 255.9025, 255.8975, 255.8975, 255.9025, 255.9000, 255.9000, 255.9000, 255.9000, 255.8900, 255.9125
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=146.627500 probe at 30.994,211.998 is z=0.977500 Tap drift (diff=145.6500mm) — reset probe at 30.994,211.998 is z=0.980000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0025mm, stable 3/5) probe at 30.994,211.998 is z=0.972500 Tap OK (diff=0.0050mm, stable 4/5) probe at 30.994,211.998 is z=0.975000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=0.9750 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.895000 probe at 30.994,211.998 is z=255.897500 Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 30.994,211.998 is z=255.902500 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=255.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=255.8950 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.900000 Tap OK (diff=0.0025mm, stable 4/5) VALIDATED: trigger_z=255.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.905000 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0050mm, stable 3/5) Tap OK (diff=0.0075mm, stable 4/5) probe at 30.994,211.998 is z=255.892500 Tap OK (diff=0.0075mm, stable 2/5) probe at 30.994,211.998 is z=255.907500 VALIDATED: trigger_z=255.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap drift (diff=0.0100mm) — reset probe at 30.994,211.998 is z=255.890000 Tap OK (diff=0.0075mm, stable 5/5) VALIDATED: trigger_z=255.8900 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Screws tilt PASS 03:27:13
probe: at 32.495,205.497 bed will contact at z=2.497500 probe: at 32.495,205.497 bed will contact at z=2.495000 probe: at 32.495,205.497 bed will contact at z=2.490000 probe: at 206.996,205.497 bed will contact at z=2.440000 probe: at 206.996,205.497 bed will contact at z=2.435000 probe: at 206.996,205.497 bed will contact at z=2.442500 probe: at 206.996,31.995 bed will contact at z=2.540000 probe: at 206.996,31.995 bed will contact at z=2.560000 probe: at 206.996,31.995 bed will contact at z=2.547500 probe: at 32.495,31.995 bed will contact at z=2.582500 probe: at 32.495,31.995 bed will contact at z=2.572500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=2.49500 front right screw : x=224.0, y=175.5, z=2.44000 : adjust CCW 00:07 rear right screw : x=224.0, y=2.0, z=2.54750 : adjust CW 00:06 rear left screw : x=49.5, y=2.0, z=2.58250 : adjust CW 00:11