← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

4A0062000F51353135323934

PASS Grade A Grade B
Model : C235 · Batch : 20260618
Heated bed : 110V · 300W · SSR SSR10DA
QC pad (MAC) : 02813B23751D
Start : 2026-07-10T05:39:31.488969 · End : 2026-07-10T05:54:06.510637 · Duration : 875 s
Received (server) : 2026-07-10T05:52:16
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=300 ssr=SSR10DA lot=20260618 uid=BBA413

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 05:39:31
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=300;ssr=SSR10DA;lot=20260618;uid=BBA413 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4A0062000F51353135323934
Home X PASS 05:44:14
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 05:44:42
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 05:45:00
Part fan PASS 05:45:03
Hotend fan PASS 05:45:08
Hotend heat 220°C PASS 05:45:08
Bed heat 60°C PASS 05:45:08
Cutter (feed+cut) PASS 05:46:34
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 05:46:45
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 05:49:11
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=256.1797 gap=1.8203 (1/4) tap 3: pos=256.7769 gap=1.2231 (2/4) tap 4: pos=256.5941 gap=1.4059 (3/4) tap 5: pos=256.1797 gap=1.8203 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=256.4326 spread=0.5972mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=153.307500 probe at 31.003,211.998 is z=153.320000 Tap drift (diff=0.0125mm) — reset probe at 31.003,211.998 is z=153.317500 Tap OK (diff=0.0025mm, stable 2/5) probe at 31.003,211.998 is z=153.312500 Tap OK (diff=0.0050mm, stable 3/5) probe at 31.003,211.998 is z=153.310000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0100mm, stable 5/5) VALIDATED: trigger_z=153.3200 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 05:53:34 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.2300, 255.7075, 255.8900, 255.8800, 255.8975, 255.9000, 255.9050, 255.9250, 255.9025, 255.9000, 255.8975, 255.8750, 255.8975, 255.8975, 255.9050
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=1.005000 probe at 30.994,211.998 is z=1.172500 Tap drift (diff=0.1675mm) — reset probe at 30.994,211.998 is z=1.200000 Tap drift (diff=0.0275mm) — reset probe at 30.994,211.998 is z=1.222500 Tap drift (diff=0.0225mm) — reset probe at 30.994,211.998 is z=1.225000 Tap OK (diff=0.0025mm, stable 2/5) probe at 30.994,211.998 is z=1.230000 Tap OK (diff=0.0050mm, stable 3/5) probe at 30.994,211.998 is z=1.227500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=1.2300 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=264.127500 probe at 30.994,211.998 is z=266.495000 Tap drift (diff=2.3675mm) — reset probe at 30.994,211.998 is z=255.695000 Tap drift (diff=10.8000mm) — reset probe at 30.994,211.998 is z=255.707500 Tap drift (diff=0.0125mm) — reset probe at 30.994,211.998 is z=255.705000 Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) VALIDATED: trigger_z=255.7075 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.872500 probe at 30.994,211.998 is z=255.890000 Tap drift (diff=0.0175mm) — reset probe at 30.994,211.998 is z=255.892500 VALIDATED: trigger_z=255.8900 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.880000 Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=255.8800 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.897500
Screws tilt PASS 05:54:06
probe: at 32.495,205.497 bed will contact at z=2.460000 probe: at 32.495,205.497 bed will contact at z=2.615000 Probe samples exceed tolerance. Retrying... probe: at 32.495,205.497 bed will contact at z=2.610000 probe: at 32.495,205.497 bed will contact at z=2.605000 probe: at 32.495,205.497 bed will contact at z=2.602500 probe: at 206.996,205.497 bed will contact at z=2.280000 probe: at 206.996,205.497 bed will contact at z=2.792500 probe: at 206.996,205.497 bed will contact at z=2.667500 probe: at 206.996,205.497 bed will contact at z=2.680000 probe: at 206.996,205.497 bed will contact at z=2.682500 probe: at 206.996,31.995 bed will contact at z=2.417500 probe: at 206.996,31.995 bed will contact at z=2.730000 probe: at 206.996,31.995 bed will contact at z=2.682500 probe: at 206.996,31.995 bed will contact at z=2.672500 probe: at 206.996,31.995 bed will contact at z=2.667500 probe: at 32.495,31.995 bed will contact at z=2.347500 probe: at 32.495,31.995 bed will contact at z=2.387500 probe: at 32.495,31.995 bed will contact at z=2.390000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=2.60500 front right screw : x=224.0, y=175.5, z=2.68000 : adjust CW 00:09 rear right screw : x=224.0, y=2.0, z=2.67250 : adjust CW 00:08 rear left screw : x=49.5, y=2.0, z=2.38750 : adjust CCW 00:26