SmartPi 1
SmartPi 2

4A0067000F51353135323934

PASS Grade A Grade B
Model : C235 · Batch : 20260618
Heated bed : 110V · 300W · SSR SSR10DA
QC pad (MAC) : 02813C788EB7
Start : 2026-07-10T05:28:37.761272 · End : 2026-07-10T05:39:20.544098 · Duration : 642 s
Received (server) : 2026-07-10T05:52:23
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=300 ssr=SSR10DA lot=20260618 uid=BBA413

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 05:28:37
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=300;ssr=SSR10DA;lot=20260618;uid=BBA413 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4A0067000F51353135323934
Home X PASS 05:29:05
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 05:29:34
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3747 gap=1.6253 (chauffe, ignore) tap 2: pos=-30.1919 gap=1.8081 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.8019 gap=2.1981 (3/4) tap 5: pos=-30.1919 gap=1.8081 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.0456 spread=0.3900mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 05:29:43
Part fan PASS 05:29:45
Hotend fan PASS 05:29:48
Hotend heat 220°C PASS 05:29:58
Bed heat 60°C PASS 05:30:04
Cutter (feed+cut) PASS 05:31:38
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-30.1919 gap=1.8081 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.0456 spread=0.1950mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 05:31:53
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 05:34:51
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.6062 gap=1.3938 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-30.1919 gap=1.8081 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.0456 spread=0.1950mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=124.657500 Tap OK (diff=0.0000mm, stable 2/5) probe at 31.003,211.998 is z=124.660000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 31.003,211.998 is z=127.540000 Tap drift (diff=2.8800mm) — reset Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) Tap drift (diff=2.8825mm) — reset Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=124.6600 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 05:38:50 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8950, 255.9000, 255.9025, 255.9025, 255.8975, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=61.385000 probe at 30.994,211.998 is z=0.867500 Tap drift (diff=60.5175mm) — reset probe at 30.994,211.998 is z=0.890000 Tap drift (diff=0.0225mm) — reset probe at 30.994,211.998 is z=0.892500 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 30.994,211.998 is z=0.895000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.8950 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.890000 probe at 30.994,211.998 is z=255.895000 Tap OK (diff=0.0050mm, stable 2/5) probe at 30.994,211.998 is z=255.900000 Tap OK (diff=0.0050mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) VALIDATED: trigger_z=255.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.902500 Tap OK (diff=0.0000mm, stable 2/5) VALIDATED: trigger_z=255.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.897500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=255.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=262.902500 Tap drift (diff=7.0025mm) — reset
Screws tilt PASS 05:39:20
probe: at 32.495,205.497 bed will contact at z=1.375000 probe: at 32.495,205.497 bed will contact at z=1.412500 probe: at 32.495,205.497 bed will contact at z=1.357500 Probe samples exceed tolerance. Retrying... probe: at 32.495,205.497 bed will contact at z=1.372500 probe: at 32.495,205.497 bed will contact at z=1.400000 probe: at 32.495,205.497 bed will contact at z=1.387500 probe: at 206.996,205.497 bed will contact at z=1.347500 probe: at 206.996,205.497 bed will contact at z=1.380000 probe: at 206.996,205.497 bed will contact at z=1.385000 probe: at 206.996,31.995 bed will contact at z=1.330000 probe: at 206.996,31.995 bed will contact at z=1.315000 probe: at 206.996,31.995 bed will contact at z=1.337500 probe: at 32.495,31.995 bed will contact at z=1.330000 probe: at 32.495,31.995 bed will contact at z=1.322500 probe: at 32.495,31.995 bed will contact at z=1.335000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=1.38750 front right screw : x=224.0, y=175.5, z=1.38000 : adjust CCW 00:01 rear right screw : x=224.0, y=2.0, z=1.33000 : adjust CCW 00:07 rear left screw : x=49.5, y=2.0, z=1.33000 : adjust CCW 00:07