| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 05:28:37 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=300;ssr=SSR10DA;lot=20260618;uid=BBA413
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=4A0067000F51353135323934
|
| Home X | PASS | 05:29:05 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=256.3991 gap=1.6009 (chauffe, ignore)
tap 2: pos=255.9969 gap=2.0031 (1/4)
tap 3: pos=255.9969 gap=2.0031 (2/4)
tap 4: pos=255.9969 gap=2.0031 (3/4)
tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
|
| Home Y | PASS | 05:29:34 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.3747 gap=1.6253 (chauffe, ignore)
tap 2: pos=-30.1919 gap=1.8081 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.8019 gap=2.1981 (3/4)
tap 5: pos=-30.1919 gap=1.8081 fenetre=0.3900/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.0456 spread=0.3900mm (tol=0.0500). Zero pose en butee=-30.0000
|
| Motherboard fan | PASS | 05:29:43 | |
| Part fan | PASS | 05:29:45 | |
| Hotend fan | PASS | 05:29:48 | |
| Hotend heat 220°C | PASS | 05:29:58 | |
| Bed heat 60°C | PASS | 05:30:04 | |
| Cutter (feed+cut) | PASS | 05:31:38 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=256.3991 gap=1.6009 (chauffe, ignore)
tap 2: pos=255.9969 gap=2.0031 (1/4)
tap 3: pos=255.9969 gap=2.0031 (2/4)
tap 4: pos=255.9969 gap=2.0031 (3/4)
tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore)
tap 2: pos=-30.1919 gap=1.8081 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.1950/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.0456 spread=0.1950mm (tol=0.0500). Zero pose en butee=-30.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 05:31:53 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 05:34:51 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=256.6062 gap=1.3938 (chauffe, ignore)
tap 2: pos=255.9969 gap=2.0031 (1/4)
tap 3: pos=255.9969 gap=2.0031 (2/4)
tap 4: pos=255.9969 gap=2.0031 (3/4)
tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore)
tap 2: pos=-30.1919 gap=1.8081 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.1950/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.0456 spread=0.1950mm (tol=0.0500). Zero pose en butee=-30.0000
Moving to tap point X=31.0 Y=212.0...
Probing with pressure switch...
probe at 31.003,211.998 is z=124.657500
Tap OK (diff=0.0000mm, stable 2/5)
probe at 31.003,211.998 is z=124.660000
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
probe at 31.003,211.998 is z=127.540000
Tap drift (diff=2.8800mm) — reset
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
Tap drift (diff=2.8825mm) — reset
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=124.6600 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 05:38:50 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8950, 255.9000, 255.9025, 255.9025, 255.8975, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000
Moving to tap point X=31.0 Y=212.0...
Probing with pressure switch...
probe at 30.994,211.998 is z=61.385000
probe at 30.994,211.998 is z=0.867500
Tap drift (diff=60.5175mm) — reset
probe at 30.994,211.998 is z=0.890000
Tap drift (diff=0.0225mm) — reset
probe at 30.994,211.998 is z=0.892500
Tap OK (diff=0.0025mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
probe at 30.994,211.998 is z=0.895000
Tap OK (diff=0.0025mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=0.8950 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0)
Z calibration complete!
probe at 30.994,211.998 is z=255.890000
probe at 30.994,211.998 is z=255.895000
Tap OK (diff=0.0050mm, stable 2/5)
probe at 30.994,211.998 is z=255.900000
Tap OK (diff=0.0050mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
VALIDATED: trigger_z=255.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 30.994,211.998 is z=255.902500
Tap OK (diff=0.0000mm, stable 2/5)
VALIDATED: trigger_z=255.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 30.994,211.998 is z=255.897500
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=255.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 30.994,211.998 is z=262.902500
Tap drift (diff=7.0025mm) — reset
|
| Screws tilt | PASS | 05:39:20 |
probe: at 32.495,205.497 bed will contact at z=1.375000
probe: at 32.495,205.497 bed will contact at z=1.412500
probe: at 32.495,205.497 bed will contact at z=1.357500
Probe samples exceed tolerance. Retrying...
probe: at 32.495,205.497 bed will contact at z=1.372500
probe: at 32.495,205.497 bed will contact at z=1.400000
probe: at 32.495,205.497 bed will contact at z=1.387500
probe: at 206.996,205.497 bed will contact at z=1.347500
probe: at 206.996,205.497 bed will contact at z=1.380000
probe: at 206.996,205.497 bed will contact at z=1.385000
probe: at 206.996,31.995 bed will contact at z=1.330000
probe: at 206.996,31.995 bed will contact at z=1.315000
probe: at 206.996,31.995 bed will contact at z=1.337500
probe: at 32.495,31.995 bed will contact at z=1.330000
probe: at 32.495,31.995 bed will contact at z=1.322500
probe: at 32.495,31.995 bed will contact at z=1.335000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=49.5, y=175.5, z=1.38750
front right screw : x=224.0, y=175.5, z=1.38000 : adjust CCW 00:01
rear right screw : x=224.0, y=2.0, z=1.33000 : adjust CCW 00:07
rear left screw : x=49.5, y=2.0, z=1.33000 : adjust CCW 00:07
|