Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 02813B23751D
Start : 2026-06-29T08:42:10.694546 · End : 2026-06-29T08:53:15.768283 · Duration : 665 s
Received (server) : 2026-06-30T01:57:38
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 08:42:10
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4B0026000F51353135323934
Home X PASS 08:42:32
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.6062 gap=1.3938 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 08:43:06
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 08:43:37
Part fan PASS 08:43:45
Hotend fan PASS 08:43:47
Hotend heat 220°C PASS 08:43:47
Bed heat 60°C PASS 08:44:04
Cutter (feed+cut) PASS 08:45:34
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.6062 gap=1.3938 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.9597 gap=1.0403 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 08:45:45
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 08:48:26
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1 rejete: cible atteinte sans buter (gap=0.0409) tap 2 rejete: cible atteinte sans buter (gap=0.0653) YUMI_SENSORLESS_HOME X: home de base suspect (pas de contact) -> re-home de recuperation 1/2 tap 3: pos=256.6062 gap=1.3938 (chauffe, ignore) tap 4: pos=255.9969 gap=2.0031 (1/4) tap 5: pos=255.9969 gap=2.0031 (2/4) tap 6: pos=255.9969 gap=2.0031 (3/4) tap 7: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (2 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.9597 gap=1.0403 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=259.335000 probe at 31.003,211.998 is z=176.052500 Tap drift (diff=83.2825mm) — reset probe at 31.003,211.998 is z=176.060000 Tap OK (diff=0.0075mm, stable 2/5) probe at 31.003,211.998 is z=176.062500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=176.0625 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 08:52:29 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=261.3350, -4.5375, 255.9050, 255.9250, 255.9000, 255.9025, 255.9000, 255.8975, 255.9025, 255.9025, 255.9000, 255.9025, 255.9000, 255.9000, 255.9025
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=261.335000 Tap OK (diff=0.0000mm, stable 2/5) probe at 30.994,211.998 is z=261.337500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=261.3350 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=263.902500 probe at 30.994,211.998 is z=248.380000 Tap drift (diff=15.5225mm) — reset probe at 30.994,211.998 is z=235.985000 Tap drift (diff=12.3950mm) — reset probe at 30.994,211.998 is z=236.772500 Tap drift (diff=0.7875mm) — reset probe at 30.994,211.998 is z=-4.542500 Tap drift (diff=241.3150mm) — reset probe at 30.994,211.998 is z=-4.537500 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) VALIDATED: trigger_z=-4.5375 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.902500 probe at 30.994,211.998 is z=255.905000 Tap OK (diff=0.0025mm, stable 2/5) VALIDATED: trigger_z=255.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.900000 probe at 30.994,211.998 is z=255.925000 Tap drift (diff=0.0250mm) — reset VALIDATED: trigger_z=255.9250 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.897500 VALIDATED: trigger_z=255.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) VALIDATED: trigger_z=255.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=255.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Screws tilt PASS 08:53:15
probe: at 32.495,205.497 bed will contact at z=1.595000 probe: at 32.495,205.497 bed will contact at z=1.632500 probe: at 32.495,205.497 bed will contact at z=1.627500 probe: at 206.996,205.497 bed will contact at z=4.750000 probe: at 206.996,205.497 bed will contact at z=4.772500 probe: at 206.996,205.497 bed will contact at z=4.807500 Probe samples exceed tolerance. Retrying... probe: at 206.996,205.497 bed will contact at z=4.805000 probe: at 206.996,205.497 bed will contact at z=4.787500 probe: at 206.996,205.497 bed will contact at z=4.845000 probe: at 206.996,205.497 bed will contact at z=4.810000 probe: at 206.996,205.497 bed will contact at z=4.752500 probe: at 206.996,205.497 bed will contact at z=4.780000 probe: at 206.996,205.497 bed will contact at z=4.762500 probe: at 206.996,205.497 bed will contact at z=4.815000 probe: at 206.996,205.497 bed will contact at z=4.820000 probe: at 206.996,205.497 bed will contact at z=4.720000 probe: at 206.996,205.497 bed will contact at z=4.747500 probe: at 206.996,205.497 bed will contact at z=4.775000 probe: at 206.996,205.497 bed will contact at z=4.817500 probe: at 206.996,205.497 bed will contact at z=4.800000 probe: at 206.996,205.497 bed will contact at z=4.785000 probe: at 206.996,31.995 bed will contact at z=5.227500 probe: at 206.996,31.995 bed will contact at z=5.322500 probe: at 206.996,31.995 bed will contact at z=5.292500 probe: at 206.996,31.995 bed will contact at z=5.262500 probe: at 206.996,31.995 bed will contact at z=5.245000 probe: at 32.495,31.995 bed will contact at z=2.917500 probe: at 32.495,31.995 bed will contact at z=2.920000 probe: at 32.495,31.995 bed will contact at z=2.902500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=1.62750 front right screw : x=224.0, y=175.5, z=4.78750 : adjust CW 06:19 rear right screw : x=224.0, y=2.0, z=5.26250 : adjust CW 07:16 rear left screw : x=49.5, y=2.0, z=2.91750 : adjust CW 02:35