← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

4B0030000F51353135323934

PASS Grade A Grade B
Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 02813C788EB7
Start : 2026-07-01T01:26:08.186163 · End : 2026-07-01T01:37:41.083838 · Duration : 692 s
Received (server) : 2026-07-01T01:42:52
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 01:26:08
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4B0030000F51353135323934
Home X PASS 01:26:29
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 01:26:56
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 01:28:49
Part fan PASS 01:28:52
Hotend fan PASS 01:28:57
Hotend heat 220°C PASS 01:28:58
Bed heat 60°C PASS 01:28:58
Cutter (feed+cut) PASS 01:30:24
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3747 gap=1.6253 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 01:30:39
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 01:33:09
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=175.855000 probe at 31.003,211.998 is z=175.862500 Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 31.003,211.998 is z=175.865000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=175.8650 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 01:37:13 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=217.9325, 257.5050, 38.8650, 255.9375, 255.9025, 255.9275, 255.9050, 255.9000, 255.9025, 255.9000, 255.8975, 255.9000, 255.9000, 255.9000, 255.9000
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=217.940000 probe at 30.994,211.998 is z=217.935000 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 30.994,211.998 is z=217.932500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=217.9325 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.902500 probe at 30.994,211.998 is z=258.382500 Tap drift (diff=2.4800mm) — reset probe at 30.994,211.998 is z=258.425000 Tap drift (diff=0.0425mm) — reset probe at 30.994,211.998 is z=261.205000 Tap drift (diff=2.7800mm) — reset probe at 30.994,211.998 is z=260.505000 Tap drift (diff=0.7000mm) — reset probe at 30.994,211.998 is z=258.702500 Tap drift (diff=1.8025mm) — reset probe at 30.994,211.998 is z=257.505000 Tap drift (diff=1.1975mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 30.994,211.998 is z=257.507500 Tap OK (diff=0.0025mm, stable 4/5) VALIDATED: trigger_z=257.5050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=264.477500 probe at 30.994,211.998 is z=38.855000 Tap drift (diff=225.6225mm) — reset probe at 30.994,211.998 is z=38.865000 Tap OK (diff=0.0100mm, stable 2/5) probe at 30.994,211.998 is z=38.867500 VALIDATED: trigger_z=38.8650 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.932500 probe at 30.994,211.998 is z=255.935000 Tap OK (diff=0.0025mm, stable 2/5) probe at 30.994,211.998 is z=255.937500
Screws tilt PASS 01:37:41
probe: at 32.495,205.497 bed will contact at z=0.747500 probe: at 32.495,205.497 bed will contact at z=0.750000 probe: at 206.996,205.497 bed will contact at z=2.405000 probe: at 206.996,205.497 bed will contact at z=2.430000 probe: at 206.996,205.497 bed will contact at z=2.420000 probe: at 206.996,31.995 bed will contact at z=3.227500 probe: at 206.996,31.995 bed will contact at z=3.282500 Probe samples exceed tolerance. Retrying... probe: at 206.996,31.995 bed will contact at z=3.257500 probe: at 206.996,31.995 bed will contact at z=3.245000 probe: at 206.996,31.995 bed will contact at z=3.260000 probe: at 32.495,31.995 bed will contact at z=2.137500 probe: at 32.495,31.995 bed will contact at z=2.117500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=0.75000 front right screw : x=224.0, y=175.5, z=2.42000 : adjust CW 03:20 rear right screw : x=224.0, y=2.0, z=3.25750 : adjust CW 05:01 rear left screw : x=49.5, y=2.0, z=2.13750 : adjust CW 02:47