| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 07:19:54 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=300;ssr=SSR10DA;lot=20260618;uid=BBA413
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=4B0047000F51353135323934
|
| Home X | PASS | 07:20:15 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=256.6062 gap=1.3938 (chauffe, ignore)
tap 2: pos=255.9969 gap=2.0031 (1/4)
tap 3: pos=255.9969 gap=2.0031 (2/4)
tap 4: pos=255.9969 gap=2.0031 (3/4)
tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
|
| Home Y | PASS | 07:20:45 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.5697 gap=1.4303 (chauffe, ignore)
tap 2: pos=-30.0091 gap=1.9909 (1/4)
tap 3: pos=-29.9847 gap=2.0153 (2/4)
tap 4: pos=-30.0091 gap=1.9909 (3/4)
tap 5: pos=-29.9847 gap=2.0153 fenetre=0.0244/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=-30.0000
|
| Motherboard fan | PASS | 07:20:52 | |
| Part fan | PASS | 07:20:54 | |
| Hotend fan | PASS | 07:20:59 | |
| Hotend heat 220°C | PASS | 07:20:59 | |
| Bed heat 60°C | PASS | 07:21:02 | |
| Cutter (feed+cut) | PASS | 07:22:33 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=256.6062 gap=1.3938 (chauffe, ignore)
tap 2: pos=255.9969 gap=2.0031 (1/4)
tap 3: pos=255.9969 gap=2.0031 (2/4)
tap 4: pos=255.9969 gap=2.0031 (3/4)
tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-30.1919 gap=1.8081 (2/4)
tap 4: pos=-29.8019 gap=2.1981 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.3900/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=-30.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 07:22:48 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 07:25:46 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=256.6062 gap=1.3938 (chauffe, ignore)
tap 2: pos=255.9969 gap=2.0031 (1/4)
tap 3: pos=255.9969 gap=2.0031 (2/4)
tap 4: pos=255.9969 gap=2.0031 (3/4)
tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Moving to tap point X=31.0 Y=212.0...
Probing with pressure switch...
probe at 31.003,211.998 is z=236.302500
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
probe at 31.003,211.998 is z=239.067500
Tap drift (diff=2.7650mm) — reset
probe at 31.003,211.998 is z=113.137500
Tap drift (diff=125.9300mm) — reset
probe at 31.003,211.998 is z=113.140000
Tap OK (diff=0.0025mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=113.1400 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 07:30:14 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1075, 255.9025, 255.9025, 255.9050, 255.9025, 255.9100, 255.8975, 255.8975, 255.9050, 255.9000, 255.9025, 255.9000, 255.9025, 255.9000, 255.8850
Moving to tap point X=31.0 Y=212.0...
Probing with pressure switch...
probe at 30.994,211.998 is z=1.100000
probe at 30.994,211.998 is z=1.102500
Tap OK (diff=0.0025mm, stable 2/5)
probe at 30.994,211.998 is z=1.105000
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
probe at 30.994,211.998 is z=1.107500
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=1.1075 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0)
Z calibration complete!
probe at 30.994,211.998 is z=255.900000
probe at 30.994,211.998 is z=255.902500
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=255.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 30.994,211.998 is z=256.135000
Tap drift (diff=0.2350mm) — reset
Tap drift (diff=0.2325mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
probe at 30.994,211.998 is z=255.915000
Tap drift (diff=0.0125mm) — reset
probe at 30.994,211.998 is z=255.905000
Tap OK (diff=0.0100mm, stable 2/5)
probe at 30.994,211.998 is z=255.912500
Tap OK (diff=0.0075mm, stable 3/5)
probe at 30.994,211.998 is z=258.897500
Tap drift (diff=2.9850mm) — reset
Tap drift (diff=2.9925mm) — reset
Tap OK (diff=0.0075mm, stable 4/5)
VALIDATED: trigger_z=255.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 30.994,211.998 is z=255.910000
Tap OK (diff=0.0100mm, stable 4/5)
probe at 30.994,211.998 is z=255.897500
Tap drift (diff=0.0100mm) — reset
Tap OK (diff=0.0075mm, stable 5/5)
VALIDATED: trigger_z=255.9100 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 30.994,211.998 is z=255.892500
|
| Screws tilt | PASS | 07:30:41 |
probe: at 32.495,205.497 bed will contact at z=0.995000
probe: at 32.495,205.497 bed will contact at z=0.997500
probe: at 32.495,205.497 bed will contact at z=1.012500
probe: at 206.996,205.497 bed will contact at z=1.285000
probe: at 206.996,205.497 bed will contact at z=1.307500
probe: at 206.996,205.497 bed will contact at z=1.290000
probe: at 206.996,31.995 bed will contact at z=0.972500
probe: at 206.996,31.995 bed will contact at z=0.957500
probe: at 206.996,31.995 bed will contact at z=0.942500
probe: at 32.495,31.995 bed will contact at z=0.947500
probe: at 32.495,31.995 bed will contact at z=0.957500
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=49.5, y=175.5, z=0.99750
front right screw : x=224.0, y=175.5, z=1.29000 : adjust CW 00:35
rear right screw : x=224.0, y=2.0, z=0.95750 : adjust CCW 00:05
rear left screw : x=49.5, y=2.0, z=0.94750 : adjust CCW 00:06
|
| QC date | Result | QC pad (MAC) | Received (server) |
|---|---|---|---|
| 2026-07-09T07:19:53.896026 | PASS | 4B0047000F51353135323934 | 2026-07-09T08:01:09 |
| 2026-07-09T07:17:15.121617 | FAIL | 4B0047000F51353135323934 | 2026-07-09T07:12:48 |
| 2026-07-09T07:14:01.056531 | FAIL | 4B0047000F51353135323934 | 2026-07-09T07:09:33 |
Moves this report to the trash — you can restore it from /trash.