← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

4B0053000F51353135323934

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 028103694A6F
Start : 2026-08-17T10:40:33.779207 · End : 2026-08-17T10:52:15.692219 · Duration : 701 s
Received (server) : 2026-08-17T05:37:35
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 10:40:33
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4B0053000F51353135323934
Home X PASS 10:41:00
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=467.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=466.9969 gap=2.0031 (1/4) tap 3: pos=466.9969 gap=2.0031 (2/4) tap 4: pos=466.9969 gap=2.0031 (3/4) tap 5: pos=466.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=466.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=467.0000
Home Y PASS 10:41:36
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-20.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-20.9969 gap=2.0031 (1/4) tap 3: pos=-20.9969 gap=2.0031 (2/4) tap 4: pos=-20.9969 gap=2.0031 (3/4) tap 5: pos=-20.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-20.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-21.0000
Motherboard fan PASS 10:41:49
Part fan PASS 10:41:51
Hotend fan PASS 10:41:54
Hotend heat 220°C PASS 10:41:56
Bed heat 60°C PASS 10:42:01
Cutter (feed+cut) PASS 10:43:37
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=467.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=467.1797 gap=1.8203 (1/4) tap 3: pos=466.8141 gap=2.1859 (2/4) tap 4: pos=467.1797 gap=1.8203 (3/4) tap 5: pos=466.9969 gap=2.0031 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=467.0426 spread=0.3656mm (tol=0.0500). Zero pose en butee=467.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-20.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-20.9969 gap=2.0031 (1/4) tap 3: pos=-20.9969 gap=2.0031 (2/4) tap 4: pos=-20.9969 gap=2.0031 (3/4) tap 5: pos=-20.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-20.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-21.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 10:43:52
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 10:47:04
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=467.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=466.9969 gap=2.0031 (1/4) tap 3: pos=466.9969 gap=2.0031 (2/4) tap 4: pos=467.1797 gap=1.8203 (3/4) tap 5: pos=467.5941 gap=1.4059 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=467.1919 spread=0.5972mm (tol=0.0500). Zero pose en butee=467.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-20.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-20.9969 gap=2.0031 (1/4) tap 3: pos=-20.9969 gap=2.0031 (2/4) tap 4: pos=-20.9969 gap=2.0031 (3/4) tap 5: pos=-20.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-20.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-21.0000 Moving to tap point X=56.0 Y=334.0... Probing with pressure switch... probe at 55.998,334.001 is z=389.415000 probe at 55.998,334.001 is z=389.420000 Tap OK (diff=0.0050mm, stable 2/5) probe at 55.998,334.001 is z=389.432500 Tap drift (diff=0.0125mm) — reset probe at 55.998,334.001 is z=391.842500 Tap drift (diff=2.4100mm) — reset probe at 55.998,334.001 is z=389.430000 Tap drift (diff=2.4125mm) — reset probe at 55.998,334.001 is z=389.427500 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0025mm, stable 3/5) probe at 55.998,334.001 is z=389.435000 Tap OK (diff=0.0050mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=389.4350 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (56.0, 334.0) ~ point de tap (56.0, 334.0) Z calibration complete!
Z tap repeatability PASS 10:51:39 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1650, 486.1100, 486.1075, 486.1025, 486.1000, 486.1025, 486.1000, 486.1025, 486.1000, 486.1000, 486.1000, 486.1025, 486.1000, 486.1025, 486.0975
Moving to tap point X=56.0 Y=334.0... Probing with pressure switch... probe at 56.001,334.001 is z=295.750000 probe at 56.001,334.001 is z=1.122500 Tap drift (diff=294.6275mm) — reset probe at 56.001,334.001 is z=1.147500 Tap drift (diff=0.0250mm) — reset probe at 56.001,334.001 is z=3.705000 Tap drift (diff=2.5575mm) — reset probe at 56.001,334.001 is z=1.157500 Tap drift (diff=2.5475mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 56.001,334.001 is z=1.160000 Tap OK (diff=0.0025mm, stable 3/5) probe at 56.001,334.001 is z=1.162500 Tap OK (diff=0.0025mm, stable 4/5) probe at 56.001,334.001 is z=1.165000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=1.1650 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (56.0, 334.0) ~ point de tap (56.0, 334.0) Z calibration complete! probe at 56.001,334.001 is z=486.105000 probe at 56.001,334.001 is z=486.107500 Tap OK (diff=0.0025mm, stable 2/5) probe at 56.001,334.001 is z=486.110000 Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=486.1100 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0000mm, stable 3/5) VALIDATED: trigger_z=486.1075 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 56.001,334.001 is z=486.100000 probe at 56.001,334.001 is z=486.102500 VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 56.001,334.001 is z=486.097500 VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0050mm, stable 4/5) Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=486.0975 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Screws tilt PASS 10:52:15
probe: at 56.003,334.994 bed will contact at z=1.335000 probe: at 56.003,334.994 bed will contact at z=1.300000 probe: at 388.002,334.994 bed will contact at z=1.147500 probe: at 388.002,334.994 bed will contact at z=1.150000 probe: at 388.002,334.994 bed will contact at z=1.160000 probe: at 388.002,110.001 bed will contact at z=1.285000 probe: at 388.002,110.001 bed will contact at z=1.280000 probe: at 56.003,110.001 bed will contact at z=1.380000 probe: at 56.003,110.001 bed will contact at z=1.370000 probe: at 221.996,222.004 bed will contact at z=1.310000 probe: at 221.996,222.004 bed will contact at z=1.300000 probe: at 221.996,222.004 bed will contact at z=1.297500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=73.0, y=305.0, z=1.33500 front right screw : x=405.0, y=305.0, z=1.15000 : adjust CCW 00:22 rear right screw : x=405.0, y=80.0, z=1.28500 : adjust CCW 00:06 rear left screw : x=73.0, y=80.0, z=1.38000 : adjust CW 00:05 rear middle screw : x=239.0, y=192.0, z=1.30000 : adjust CCW 00:04